A
BOUT
THE
S
YSTEM
I
NTRODUCTION
1-1
1.1
Introduction
Specifications
*
1
Performance criteria A: Normal performance, Performance criteria C: System reset.
*
2
Please notice if IronRAN-RUx MO is placed in a -40°C environment for over 1 hour, warm up this device
over 1.5 hours is required before cell connection.
Table 1-1: Specifications
S
PECIFICATIONS
D
ESCRIPTION
Memory
2GB DDR3
Power supply
110/220 AC In
Power consumption
Max. 180W
System rating
100-240Vac, 50/60Hz, 4.7A
Front IO
1 x AC Port
1 x SFP+ 10G
1 x Management port (RJ45)
1 x Console Port (RJ45)
Indicators
Power Status
Working Status
Warning Status
SFP+ Status
Dimension
Without cage shade: 418.5 x 312 x 152 mm (16.48 x 12.28 x 5.99 in.)
With cage shade: 418.5 x 355 x 165 mm (16.48 x 13.98 x 6.50 in.)
Weight
15 KG (33.06 lbs)
Fan
Fan-less design
Placement
Wall-mount, pole-mount
Surge protection
IEC 61000-4-5 Level 3 (2KV), performance criteria: A*
1
IEC 61000-4-5 Level 3 (4KV), performance criteria: A*
1
GR-1089 6KV, performance criteria: A*
1
Operating
temperature
-40°C ~ +55°C (-40°F ~ +131°F): US*
2
Operating humidity
RH 5% ~ 95%
Ingress protection
IP65
MTBF
> 100,000 hrs
Certification
US: FCC/CSA