BMC
SMASH
4-10
*The sensor name list depends on the Server Hardware.
/SYS/powerSupply
This command provides the specification of the Sensor Type sensor-specific event.
*The sensor name list depends on the Server Hardware.
Q&A:
Q1: My system supports two power supply slots and only one power supply unit con-
nected. What is the other power supply status?
Table 4.6: /SYS/temperature
P
ROPERTY
N
AME
V
ALID
V
ALUE
A
CCESS
D
ESCRIPTION
Sensor name list of
temperature
na
ok
nonCritical
critical
R
na
indicates the status not available /unknown
(typically because system power is off )
ok
indicates the monitored parameters within nor-
mal operating ranges
nonCritical
indicates the hardware outside normal operat-
ing range
critical
indicates the hardware exceeding specified rat-
ings
Table 4.7: /SYS/powerSupply
P
ROPERTY
N
AME
V
ALID
V
ALUE
A
CCESS
D
ESCRIPTION
Sensor name list of
power supply
Presence*
FailDetected*
PredictiveFail*
InputLost(AC/
DC)*
AllDeasserted
(*Note: Only for
certain models.)
R
Presence
indicates the Power Supply Presence detected
FailDetected
indicates the Powser Supply Failure detected
PredictiveFail
indicates the Power Supply Predictive Failure,
the status supported or not depends on project
InputLost(AC/DC)
indicates the Power Supply input lost, such as
power cord not inserted
AllDeasserted
indicates the power supply is not inserted
Redundancy
FullyRedundant
RedundancyLost
R
The property is provided depend on project.
FullyRedundant
Indicates the power redundancy is OK.
RedundancyLost
Indicates the power redundancy is fail. One PSU
is removed or AC lost.
Summary of Contents for QuantaGrid Series