background image

QuantaMesh 

T7080-IXA 

Network Switch 

Installation Guide 

Summary of Contents for QuantaMesh T7080-IXA

Page 1: ...QuantaMesh T7080 IXA Network Switch Installation Guide...

Page 2: ......

Page 3: ...nology Equipment ITE which may be installed in offices schools computer rooms and similar commercial type locations The suitability of this product for other product categories and environments such a...

Page 4: ...ly be serviced by trained service technician If any of the following conditions occur unplug the equipment from the electrical outlet and replace the part or contact a trained service technician The p...

Page 5: ...ion cable with properly grounded plugs Observe extension cable and power strip ratings Ensure that the total ampere rating of all products plugged into the extension cable or power strip does not exce...

Page 6: ...ack kit The rail racks are designed to carry only the weight of the system Do not place additional load onto any rail mounted equipment System rack kits are intended to be installed in a rack by train...

Page 7: ...e power cord to the power supply being replaced before removing it from the switch Power Cord Warnings If an AC power cord was not provided with your product purchase one that is approved for use in y...

Page 8: ...te the system without the fan guard in place Rack Mount Warnings The following installation guidelines are required by UL for maintaining safety compliance when installing your into a rack The equipme...

Page 9: ...otherwise damage a battery Cooling and Airflow CAUTION Carefully route cables as directed to minimize airflow blockage and cooling problems For proper cooling and airflow operate the system only with...

Page 10: ...expressly approved by the grantee of this device could void the user s authority to operate the equipment The customer is responsible for ensuring the compliance of the modified product Only periphera...

Page 11: ...and TUV and VDE licensed Maximum power rating of any one device is 19 watts Total server configuration is not to exceed the maximum loading conditions of the power supply Restriction of Hazardous Sub...

Page 12: ...mplies with Part 15 of the FCC Rules Operation of this device is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference...

Page 13: ...Hardware 20 Package Contents 20 Installing the Switch 20 Site Survey 20 Positioning the Switch 21 Mounting the Switch into Ozeki Rack with BES 53248A1 ZRMK Rail Kit 21 Connecting to the Console Port...

Page 14: ...on chip T7080 IXA is rated at 4B PPS processing and includes a 16GB deep packet buffer with HBM It enables zero packet loss in heavily congested networks and more efficient traffic management T7080 IX...

Page 15: ...and there is data activity Off No link 50G Link Activity Purple Solid The port is linked Purple Blinking The port has link established and there is data activity Off No link 40G Link Activity Blue So...

Page 16: ...Description LED State Definition Switch Power LED Power Green solid Valid power All monitored voltages are nominal Off No Power Some Power rails are dropping below specification Switch System Event L...

Page 17: ...or on lane 1 0 0 1 0 2 Indicate error on Lane 2 RED or YELLOW if any error on Lane 2 Green if no error on lane 2 0 1 0 0 3 Indicate error on Lane 3 RED or YELLOW if any error on Lane 3 Green if no err...

Page 18: ...more detail information Data Port Connection Supported Cables and Transceivers See the following table for the list of supported cables and transceivers Supported Distance Description Note 1m 40G Dire...

Page 19: ...pports 40G or 100G by using 40G or 100G cables or optical transceivers The switch can support fan out cable for 40G to 4 x 10G or 100G to 4 x 25G or 2 x 50G The QSFP28 ports are numbered and have corr...

Page 20: ...onnector is a standard three pronged connector The switch automatically adjusts its power setting to any supply voltage in the range from 100 240 VAC at 50 60 Hz NOTE Verify that each module has the s...

Page 21: ...e airflow is front to back CAUTION Do not mix power supplies and fan modules with different airflow in the same chassis Front to Back Airflow The air intake is located on the front panel of the switch...

Page 22: ...flat and stable surface and cut the straps securing the box 2 Carefully remove the switch Then place it on a flat and clean surface 3 Remove all other items from the box and inspect each item Install...

Page 23: ...retainer is color coded to indicate its airflow direction Blue indicates back to front airflow air outlet module To ensure proper airflow make sure that when you install the switch its air intake is...

Page 24: ...ps to remove another inner rail and install the mounting ear 5 Install the outer rails to the rack To install the front bracket Pull the latch and install the rail by aligning the hooks with the front...

Page 25: ...e inner rail to the switch with the screws Front Installation Rear Installation NOTE Repeat the similar steps to install another inner rail 8 Slide the inner rails on the switch into the middle rails...

Page 26: ...able for serial communication Below is the console cable wiring specification table RJ 45 Port of Switch DB9 Female Port of PC Abbreviation Description 3 2 RD Received Data 6 3 TD Transmit Data 1 8 CT...

Page 27: ...erate in either half or full duplex and data rate can be in 10Mbps 100Mbps or 1Gbps Telnet SNMP and Web browser utility can all go through this port for local or remote management after the IP address...

Page 28: ...ly The switch is equipped with four slots for power supplies Four circuits provide redundancy protection you may hot swap one or two PSUs during operations NOTE Each PSU has an AC power connector At l...

Page 29: ...able port module PSU LED is in Red state Possible issues Fan Lock 15 sec OTP Over Temperature Process OCP Over Current Process OVP Over Voltage Process UVP Under Voltage Process Fan LED is in Red stat...

Page 30: ...ly For switches that only using a single power supply removing the power supply will cause the switch to automatically shutdown The PSUs can be replaced without the use of special tools Before replaci...

Page 31: ...e handle to slide the fan module away from the chassis NOTE Take note of the part number of the removed fan module When making order for replacement modules make sure that the part number of the new f...

Page 32: ...of different protocols i e FTP TFTP and HTTP to download the installer file from your local server To download and update the vendor OS code manually perform the following 3 Locate the specific QUANT...

Page 33: ...t 6 In ONIE Linux shell use the install_url command to update the vendor OS code Use one of the following commands install_url tftp 192 168 2 153 ly3 onie installer 1 5 3 or install_url ftp 192 168 2...