background image

QuantaMesh

Network Switch

Installation Guide

Summary of Contents for QuantaMesh

Page 1: ...QuantaMesh Network Switch Installation Guide...

Page 2: ...uter rooms and similar commercial type locations The suitability of this product for other product categories and environments such as medical industrial residential alarm systems and test equipment o...

Page 3: ...ble or plug is damaged The equipment has been exposed to water The equipment has been dropped or damaged The equipment does not operate correctly when you follow the operating instructions Do not spil...

Page 4: ...e following guidelines Unplug the power cable before removing the power supply Install the power supply to the system before connecting the power cable to the power supply If the system has multiple s...

Page 5: ...or equipment damage Conform to local occupational health and safety requirements when moving and lifting equipment Use mechanical assistance or other suitable assistance when moving and lifting the eq...

Page 6: ...fety instructions apply whenever accessing the inside of the product Turn off all peripheral devices connected to this product Disconnect the AC power by unplugging all AC power cords from the system...

Page 7: ...operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circui...

Page 8: ...not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encou...

Page 9: ...or UL listed Any add in card containing modem telecommunication circuitry must be UL listed In addition the modem must have the appropriate telecommunications safety and EMC approvals for the region...

Page 10: ...omplies with Part 15 of the FCC Rules Operation of this device is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interferenc...

Page 11: ...9 24 Data Port Connection 24 Fan Tray of T3048 LY9 26 Power Supply of T3048 LY9 26 Airflow Direction 27 Chassis for the T3048 LY5A Switch 28 Ports of T3048 LY5A 29 Data Port Connection 29 Fan Tray of...

Page 12: ...46 Installation 46 In Band Access 46 Replacing the Power Supply 47 Replacing the Fan Tray 49 Customer Support 49 Appendix 50 Initial Configuration Process 50 Configure the IP Address 50 Set IP Addres...

Page 13: ...on to server Chassis for the T1048 P02 Series Switch Front panel T1048 P02S QuentaMesh 1 2 11 12 9 10 7 8 5 6 3 4 13 14 23 24 21 22 19 20 17 18 15 16 25 26 35 36 33 34 31 32 29 30 27 28 37 38 47 48 45...

Page 14: ...ssis is equipped with the following ports 48 10 100 1000Base T 4 GE Base X SFP T1048 P02 or 4 10GE Base X SFP T1048 P02S 1 Management ports 1 Console port The chassis has 48 triple speed 10 100 1000 B...

Page 15: ...R optic 10G optic SFP LC 850nm MMF 10GBASE SR optic 10G optic SFP LC 1310nm SMF 10GBASE LR optic NOTE For more information about the cable transceiver please contact QCT sales Base T Port Connection T...

Page 16: ...e Ethernet for fiber mediums The SFP SFP ports are numbered and have corresponding SFP SFP port LEDs To install an SFP SFP module do the following 1 Slide the SFP SFP module into an SFP SFP port NOTE...

Page 17: ...13 16 15 18 17 20 19 22 21 24 23 25 26 35 36 33 34 31 32 29 30 27 28 26 25 28 27 30 29 32 31 34 33 36 35 37 38 47 48 45 46 43 44 41 42 39 40 38 37 40 39 42 41 44 43 46 45 48 47 50 57 60 59 58 52 65 6...

Page 18: ...ble One USB port enables you to load the configuration files from a USB storage device to the switch s flash memory NOTE The USB port function will be supported in the future release Data Port Connect...

Page 19: ...P SMF NOTE For more information about the cable transceiver please contact QCT sales SFP Port Connection LC Type Connector The switch is equipped with 48 SFP ports The Small Form Factor Pluggable Plus...

Page 20: ...le into a QSFP port 2 Push completely until the module locks into place 23 24 21 22 19 20 17 18 18 17 20 19 22 21 24 23 25 26 26 25 50 57 60 59 58 52 65 68 67 66 49 53 56 55 54 51 61 64 63 62 AC DC 70...

Page 21: ...SU handle AC power connector Plug retainer The AC power connector is a standard three pronged connector The switch automatically adjusts its power setting to any supply voltage in the range from 100 2...

Page 22: ...airflow in the same chassis CAUTION Front to Back Airflow The air intake is located on the front panel of the switch The cool air is sucked in from outside the chassis and pushed toward the rear of th...

Page 23: ...62 67 68 63 64 2 3 1 5 7 6 4 13 12 14 8 9 11 10 No Item No Item 1 10GBASE T Ports 8 System info LED 2 10GBASE T Port LEDs 9 Console Port 3 QSFP Ports 10 Power LED 4 QSFP Port LEDs 11 Management Port 5...

Page 24: ...les you to load the configuration files from a USB storage device to the switch s flash memory NOTE The USB port function will be supported in the future release Data Port Connection Supported Cables...

Page 25: ...tor The switch is equipped with 6 QSFP Quad SFP ports There are two types of QSFP ports There are four 40G QSFP ports on the front panel which support 40G per port or fan out to 4x10G by using the fan...

Page 26: ...power supply modules If the switch uses two power supply modules you can hot swap one of the PSU during the operations NOTE Only one PSU is required to operate a fully loaded chassis There are two ty...

Page 27: ...cates front to back airflow air inlet module Blue indicates back to front airflow air outlet module Do not mix power supplies and fan modules with different airflow in the same chassis CAUTION Front t...

Page 28: ...75 76 78 53 77 79 80 82 54 81 83 84 86 55 85 87 88 90 56 89 91 92 94 57 93 95 96 98 58 97 99 100 102 59 101 103 104 106 60 105 107 108 PSU1 PSU2 FAN 4 8 11 10 7 3 9 6 5 12 13 14 1 2 No Item No Item 1...

Page 29: ...cable One USB port enables you to load the configuration files from a USB storage device to the switch s flash memory NOTE The USB port function will be supported in the future release Data Port Conne...

Page 30: ...NOTE For more information about the cable transceiver please contact QCT sales SFP Port Connection LC Type Connector The switch is equipped with 48 SFP ports The Small Form Factor Pluggable Plus SFP p...

Page 31: ...37 37 38 39 40 41 42 43 44 45 39 41 43 92 94 57 93 95 96 98 58 97 99 100 102 59 101 103 104 106 60 105 107 108 3 Repeat the above procedures to install additional QSFP modules The QSFP port LED light...

Page 32: ...nge from 100 240 VAC at 50 60 Hz NOTE Verify that each module has the same airflow direction Make sure the switch runs with all of its power supply and fan tray modules taking in air from a cold aisle...

Page 33: ...usts through the vents on the rear panel of the switch PSU 2 PSU 1 FAN 3 FAN 2 FAN 1 750w AC AC DC 750w AC AC DC Rear panel Back to Front Airflow The air intake is located on the rear panel of the swi...

Page 34: ...anel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 20 31 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 32 PSU 2 PSU 1 T5032 LY6...

Page 35: ...ort enables you to load the configuration files from a USB storage device to the switch s flash memory NOTE The USB port function will be supported in the future release Data Port Connection Supported...

Page 36: ...tion The QSFP ports are numbered and have corresponding QSFP port LEDs To install a QSFP module do the following 1 Slide the QSFP module into a QSFP port 2 Push completely until the module locks into...

Page 37: ...z NOTE Verify that each module has the same airflow direction Make sure the switch runs with all of its power supply and fan tray modules taking in air from a cold aisle and exhausting air to the hot...

Page 38: ...es with different airflow in the same chassis CAUTION Front to Back Airflow The air intake is located on the front panel of the switch The cool air is sucked in from outside the chassis and pushed tow...

Page 39: ...switch Then place it on a flat and clean surface 3 Remove all other items from the box and inspect each item Installing the Switch Site Survey Consider the following when choosing a location to instal...

Page 40: ...w direction Make sure the switch runs with all of its power supply and fan tray modules taking in air from a cold aisle and exhausting air to the hot aisle Rack Mounting the Switch You can install the...

Page 41: ...lign the brackets to the rail holes and secure them with screws 1 2 11 12 9 10 7 8 5 6 3 4 2 1 4 3 6 5 8 7 10 9 12 11 13 14 23 24 21 22 19 20 17 18 15 16 14 13 16 15 18 17 20 19 22 21 24 23 25 26 35 3...

Page 42: ...d 8 7 RTS Request To Send 5 5 GND Ground Using the console port you can perform the following Configure the switch using the CLI commands Manage and monitor network activity by Command Line Interface...

Page 43: ...e management after the IP address subnet mask and default gateway are properly configured To avoid an IP address conflict make sure to complete the initial configuration see Connecting to the Console...

Page 44: ...has an AC power connector At least one power supply must connect to a power source To connect the switch to a power source do the following 1 Connect one end of the AC power cord to an AC power connec...

Page 45: ...0M left LED Powering On All Fans Working Good Amber Booting On Going 1G left LED Red Powering Failed Some Fans Failed Fan Failed Dark Powering Off Booting Failed 10M left LED Blinking Activity right L...

Page 46: ...not turn on when the power cord is plugged in you may have a problem with the power outlet power cord or power supply However if the unit powers off after running for a while check for loose power con...

Page 47: ...In the event of a power supply failure you can replace the defective unit without powering down the system provided that there is at least one power supply must connect to a power source To replace th...

Page 48: ...m the chassis NOTE Take note of the part number of the removed PSU When making order for replacement modules make sure that the part number of the new PSU is the same as the part number of the removed...

Page 49: ...e retainer and pull by the handle to slide the fan module away from the chassis AC DC AC DC 70 69 NOTE Take note of the part number of the removed fan module When making order for replacement modules...

Page 50: ...he switch For the first time configuration it is recommended to set the IP address manually Set IP Address Manually To set the IP address of the switch manually perform the following 1 Connect the swi...

Page 51: ...here gateway is a value between 0 0 0 0 to 255 255 255 255 8 From this point the IP address subnet mask and gateway of the switch has been set On the command prompt input exit to go back one level The...

Page 52: ...d monitor network elements The switch supports SNMP version 1 0 2 0 and 3 0 The basic components and functions of SNMP are as follows A Managed Device in this case the switch An SNMP Agent SNMP Manage...

Page 53: ...the following 1 Connect the TFTP server to the switch via the management port 2 Set the service port IP address using the following commands a Connect the console cable to the console port b On a term...

Page 54: ...ntains 2 images you need to remove one of the images and use the delete image name command to delete the non startup image 5 Input the following command to update the image copy tftp server ip addr fi...

Page 55: ...e the kernel and root file system perform the following 1 Connect the TFTP server to the switch via the management port 2 Set the service port IP address using the following commands a Connect the con...

Page 56: ...latest image file img in its root directory assuming that the IP address is 192 168 2 100 NOTE Take note where the image is saved 4 Use the following commands to download package file copy tftp serve...

Page 57: ...Locate the specific QUANTA ONIE installer image that you want to download For example the installer file name ly3 onie installer 1 5 3 2 Place the installer file into your local FTP TFTP or HTTP serve...

Page 58: ...ode Use one of the following commands install_url tftp 192 168 2 153 ly3 onie installer 1 5 3 or install_url ftp 192 168 2 153 ly3 onie installer 1 5 3 or install_url http 192 168 2 153 ly3 onie insta...

Reviews: