13
• Step 3: Nominal mode
State
Information
Green blinking:
1
very
short flash (300 ms)
spaced 4 seconds
apart
OK
Green blinking:
2
very
short and consecutive
flashs (300 ms)
spaced 4 seconds
apart
Warning: Fail Soft Mode Level 1
Frequent device reboot detected (for example 4 times in less than ½ hour)
Message is displayed on the screen: «Fail Soft Mode: waiting for new content ».
The instability has been caused probably by a content media not supported yet by the Gekkota OS. Consequently, to
prevent any further reboot, the content has been invalided. The message displayed on the screen indicates that a
new publication is needed to go ahead. ²
Green blinking:
3
very
short and consecutive
flashs (300 ms)
spaced 4 seconds
apart
Warning: Fail Soft Mode Level 2
Frequent device reboot detected (for example 4 times in less than ½ hour)
Content is purged
Message is displayed on the screen «Fail Soft Mode: waiting for new content ».
The instability has been caused probably by a content not supported yet by system or one user preference which
has been modified. Consequently, to prevent any further reboot, the content has been invalidated and user
preferences (saved before unexpected reboot) have been restored. The message displayed on the screen indicates
that a new publication is needed to go ahead. ²
Green blinking:
4
very
short and consecutive
flashs (300 ms)
spaced 4 seconds
apart
Warning: Check disk
The device has detected memory corruption on content storage. The media storage is being repaired. This repair
step is called Check-Disk and its duration can be several minutes. During this step, a message “checking the file
system of data partition in progress” is displayed on the screen. ³
Green blinking:
5
very
short and consecutive
flashs (300 ms)
spaced 4 seconds
apart
Warning: errors on system partition
The user has to connect to device Web user interface, go to
Maintenance > Tools
menu, and click on the
Format
or
Repair
button to solve the problem. ³
Green blinking:
6
very
short and consecutive
flashs (300 ms)
spaced 4 seconds
apart
Warning: a middleware upgrade is pending
During this phase, no content is played on the device,
do not switch OFF the device.
Green blinking:
7
very
short and consecutive
flashs (300 ms)
spaced 4 seconds
apart
Error: write problem on the storage
For an unknown reason, your storage space isn't usable any more. ³
Off
Error
. ¹
¹ If the problem persists in despite of an appropriate power-supply, contact
² If the problem persists, it is recommended to find out the media not supported yet by the system and remove it from content.
³ If the problem persists after a partition repairing, contact
.
Summary of Contents for DMB400
Page 1: ...User manual DMB400 4 14 14 002D...
Page 4: ...4 Part I Description and installation...
Page 7: ...7 1 2 1 Device xture...
Page 8: ...8 1 2 2 Device dimensions...
Page 18: ...18 Part II Applicative user interface...
Page 20: ...20 Part III Administration console user interface...
Page 48: ...48 Part IV Con guration by script...
Page 50: ...50 Part V Technical information...
Page 54: ...54 Part VI Contacts...
Page 56: ...56 Part VII Appendix...