MDO_P1P44F-010: Operator Manual
49/55
16. Alarms
F5
Clear all alarms
The alarms block all machine operations.
Alarm
Cause
Solution
Emergency
Stop for emergency switch
-
Y axis limit switch FW
The Y-axis has encountered the forward limit switch
-
Y axis limit switch BW
The Y-axis has encountered the backrward limit switch
-
Z axis limit switch UP
The Z-axis has encountered the up limit switch
-
Z axis limit switch DOWN
The Z-axis has encountered the down limit switch
-
X axis limit switch FW
The X-axis has encountered the forward limit switch
-
X axis limit switch BW
The X-axis has encountered the backrward limit switch
-
H axis limit switch FW
The H-axis has encountered the forward limit switch
-
H axis limit switch BW
The H-axis has encountered the backrward limit switch
-
Tool not running
The disk must be moving during the automatic cycle
-
No water pressure
Missing of cooling water
Control the water flowstate
Mandrel motor overcurrent
The absorption of the motor disk is over the alarm threshold
-
No oli pressure
Missing of pressure in the lubrication circuit
Check the oil flowstate
X encoder fault
Failure to detect counter
Check the encoder
Y encoder fault
Z encoder fault
W encoder fault
H encoder fault
Thermal outout tripped
A thermal drive has been activated
-
Fault inverters
Fault of the axes inverter
-
Spindle inverter fault
Fault of the spindle inverter
-
CAN module disconnected
The remote module does not communicate
Check the settings and the cable
CAN2 module disconnected
X axis out of tolerance
Positioning ended out of tolerance
Check the axis parameters
Y axis out of tolerance
Z axis out of tolerance
W axis out of tolerance
H axis out of tolerance
Safety enclosure alarm
Perimeter safety protection barriers have been opened
-
No air pressure
Missing of pressure in the air circuit
Check the air flowstate
Wait for power system…
Inactive auxiliary inputs. Communication interrupted with the 2nd
RMC1S module at input I74.
Activate auxiliary inputs. Check
communication with the 2nd
RMC1S module.
No power system
Machine auxiliaries are deactivated
-
Inverter generic fault
Inverters have a non-resetable error
Contact the manufacturer of the
inverter
Bride out of guides
Reports that the bridge has lift and the I79 limit switch has
intervened.
Reset the alarm and bring the
bridge back to the binars
Summary of Contents for MDO P1P44F-010
Page 3: ...MDO_P1P44F 010 Operator Manual 1 55 MDO_P1P44F 010 Operator Manual ...
Page 6: ...MDO_P1P44F 010 Operator Manual 4 55 Profiling Flattening ...
Page 7: ...MDO_P1P44F 010 Operator Manual 5 55 3 Hardware J1 P44 FB20 ...
Page 8: ...MDO_P1P44F 010 Operator Manual 6 55 J1 P44 FB20 J1 P44 Fx Installation and Maintenance Manual ...
Page 12: ...MDO_P1P44F 010 Operator Manual 10 55 4 Main menu F6 ...
Page 13: ...MDO_P1P44F 010 Operator Manual 11 55 ...
Page 18: ...MDO_P1P44F 010 Operator Manual 16 55 8 Manual Semi Automatic F6 ...
Page 25: ...MDO_P1P44F 010 Operator Manual 23 55 11 Muliple Cuts Automatic F6 ...
Page 26: ...MDO_P1P44F 010 Operator Manual 24 55 ...
Page 31: ...MDO_P1P44F 010 Operator Manual 29 55 12 Tilted Cuts Automatic ...
Page 32: ...MDO_P1P44F 010 Operator Manual 30 55 F6 H axis without ENCODER ...
Page 36: ...MDO_P1P44F 010 Operator Manual 34 55 ...
Page 38: ...MDO_P1P44F 010 Operator Manual 36 55 14 Programming and executing profiles F6 RUN ...
Page 40: ...MDO_P1P44F 010 Operator Manual 38 55 14 2 Profiles F6 ...
Page 45: ...MDO_P1P44F 010 Operator Manual 43 55 14 2 2 Profiles parameters ...
Page 48: ...MDO_P1P44F 010 Operator Manual 46 55 ...
Page 53: ...MDO_P1P44F 010 Operator Manual 51 55 17 Diagnostic F6 PASSWORD 462 I O INPUTS OUTPUTS ...