32
EN
SLOPE SETTING
Press this button for 2 sec. to enter into the slope mode. The X symbol and „+“ will flash. The curser
is below the sign. Change the sign with the buttons
. Press the button short to go to the next
digit. Set the slope values with these buttons. Press the button again to select the next digit. Press
the button again long to select the slope setting of the Y axis. The slope setting of the Y axis is the
same as above. After 8 sec. without entry the instrument will automatically store the values set. For
confirmation the instrument will beep. Then, the TILT mode preparation will start (3 status).
TILT FUNCTION
Powering on the laser the TILT function will be activated automatically. „TILT“ is flashing during the
activation procedure. When the activation is completed (after 90 sec approx.) „TILT“ is indicated perma-
nently.
Press button
to switch this function on/off.
When the TILT function is active:
If the laser is disturbed, the rotation stopps and the laser beam and „TILT“ will flash. The laser will not
re-level automatically.
If required self-levelling procedure can be reactivated with button
.
This instrument has three TILT status:
Activation
=„TILT“ flashes slowly during the activation, the instrument in not yet ready for use
Function active
= TILT“ is indicated permanently
TILT alarm
= „TILT“ is flashing quickly and the rotation stopps.
VIBRATION-WIND-SECURITY
(VWS FUNCTION)
Press this button to activate the VWS mode. The VWS function automatically activates the TILT function.
This function allows continuous operation during periods of vibration and wind. If a significant movement
occurs the laser stops rotating and the TILT LED starts flashing. Press the VWS button to cancel. Press
the VWS button again to re-activate.
Summary of Contents for FL 150H-G
Page 25: ...25 DE ...
Page 49: ...49 EN ...