SAFETY INSTRUCTIONS

 · Follow up the instructions given in the user manual. 

 · Do not stare into the beam. The laser beam can lead to eye injury. A direct look into the beam (even from greater 

distance) can cause damage to your eyes.

 · Do not aim the laser beam at persons or animals. 

 · The laser plane should be set up above the eye level of persons. 

 · Use the instrument for measuring jobs only.

 · Do not open the instrument housing. Repairs should be carried out by authorized workshops only. Please contact 

your local dealer.

 · Do not remove warning labels or safety instructions.

 · Keep the instrument away from children.

 · Do not use the instrument in explosive environment.

 · The user manual must always be kept with the instrument.

LASER CLASSIFICATION 

The instrument is a laser class 2 laser product according to DIN IEC 60825-1:2014.

It is allowed to use unit without further safety precautions.

Eye protection is normally secured by aversion responses and the blink reflex.

The laser instrument is marked with class 2 warning labels.

Please note:

If you return instruments for repair / for adjustment to us please disconnect batteries or rechargeable batteries 
from the instrument - this is for safety reasons! 
Thank you.

INTENDED USE OF INSTRUMENT

The instrument emits a visible laser beam in order to carry out the following measuring tasks (depending on the instru-

ment): Setting up heights, horizontal and vertical planes, right angles.

Laser 

2

IEC 60825-1:2014

P ≤ 1 mW @ 635 - 670 nm

www.geo-fennel.de

GERMANY

Summary of Contents for Geo5P

Page 1: ...BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI www geo fennel de www geo fennel com www geo fennel fr DE EN FR Geo5P ...

Page 2: ...eitshinweise vor der Inbetriebnahme aufmerksam durch Nur ein sachge rechter Gebrauch gewährleistet einen langen und zuverlässigen Betrieb geo FENNEL Precision by tradition Inhaltsverzeichnis 1 Lieferumfang A 2 Bedienelemente B 3 Bedienung C 4 Sicherheitshinweise D Selbstnivellierender 5 Punktlaser Geo5P Multifunktionale Halterung Magnetische Zieltafel 3 x AA Alkalinebatterien Geopolstere Tasche Be...

Page 3: ... 4 Screw On Off switch Output window Output window 1 3 2 1 Laseraustrittsfenster 2 AN AUS Knopf 3 1 4 Gewinde Kamerastativ 4 Batteriefachdeckel 5 Laseraustrittsfenster 6 1 4 Adapter 7 Magnete 8 5 8 Gewinde für Baustativ 9 Magnete 10 Schlitze für Befestigungsriemen 11 Öffnung für Lochhängung 12 Schraube zum Befestigen des Gerätes auf der multifunktionalen Halterung Self calibration aperture Battery...

Page 4: ...nde Punkte und akustischer Alarm zeigt an dass das Gerät ausserhalb des Selbstnivellierbereiches aufgestellt wurde In diesem Fall eine waagerechte Position suchen Der Geo5P kann mit dem 1 4 Gewinde 3 direkt auf ein Kamerastativ montiert werden MULTIFUNKTIONALE HALTERUNG Gerät mit der multifunktionalen Halterung verbinden Nun kann das Gerät mit einem Bau oder Kurbelstativ mit 5 8 Gewinde verbunden ...

Page 5: ...und Laserpunkt B markieren Gerät um 180 zu Position B drehen und Laserpunkt C markieren Wenn die horizontale Differenz der 3 Punkte A B und C nicht größer als 4 mm ist liegt das Gerät innerhalb der Toleranz Wenn die Abweichung größer als 4 mm ist ist das Gerät dejustiert In diesem Fall wenden Sie sich bitte an geo FENNEL oder einen autorisierten Fachhändler Befestigung an einem Nagel einer Schraub...

Page 6: ... unterliegen nicht der Garantie Der Garantieanspruch erlischt wenn das Gehäuse geöffnet wurde Der Hersteller behält sich vor im Garantiefall die schadhaften Teile instand zusetzen bzw das Gerät gegen ein gleiches oder ähnliches mit gleichen technischen Daten auszutauschen Ebenso gilt das Auslaufen der Batterie nicht als Garantiefall HAFTUNGSAUSSCHLUSS 1 Der Benutzer dieses Produktes ist angehalten...

Page 7: ...r Lasereinrichtung mitzugeben LASERKLASSIFIZIERUNG Das Gerät entspricht der Lasersicherheitsklasse 2 gemäß der Norm DIN IEC 60825 1 2014 Das Gerät darf ohne weitere Sicherheitsmaßnahmen eingesetzt werden Das Auge ist bei zufälligem kurzzeitigem Hineinsehen in den Laserstrahl durch den Lidschlussreflex geschützt Laserwarnschilder der Klasse 2 sind gut sichtbar am Gerät angebracht Bitte unbedingt be...

Page 8: ...y instructions A proper use only guarantees a longtime and reliable operation geo FENNEL Precision by tradition Contents 1 Supplied with A 2 Features B 3 Operation C 4 Safety notes D Self levelling 5 Point Laser Geo5P Multi functional mount Magnetic target 3 x AA Alkaline battery Padded carrying case User manual SUPPLIED WITH A FUNCTIONS For plumbing alignments levelling transfer of points and man...

Page 9: ...6 1 4 adapter 7 Magnets 8 5 8 thread for builder s tripod 9 Magnets 10 Slits for fixing belts 11 Hanging hole 12 Screw for fixing the instrument on the multi functional mount 1 4 Screw On Off switch Output window Output window 1 3 2 Instrument fixing hand whe Hanging hole Strong megnet Belt slot 9 11 12 10 1 4 Screw 1 4 5 8 Screw Strong megnet 7 8 6 Self calibration aperture Battery cover Output w...

Page 10: ...ft right A visual blinking laser points and audible alarm indicates that the unit was set up outside of the compensator range Set it up on a more even surface Geo5P can be connected to a camera tripod or a floor to ceiling pillar by means of the 1 4 thread 3 MULTI FUNCTIONAL MOUNT Connect Geo5P to the multi functional mount Now it can be connected to a builders or elevating tripod by means of the ...

Page 11: ...t by 180 to position B and mark laser point C The horizontal deviation of the 3 marked points A B and C must not exceed 4 mm If the deviation exceeds 4 mm the instrument is out of tolerance In this case please contact an authorized workshop Fix it to horizontal or vertical frames poles pipes by use of the fixing strap Fix the instrument to a nail screw with the hole of the multi functional mount E...

Page 12: ...harge for either parts or labour In case of a defect please contact the dealer where you originally purchased this product The warranty will not apply to this product if it has been misused abused or altered Without limiting the foregoing leakage of the battery bending or dropping the unit are presumed to be defects resulting from misuse or abuse EXCEPTIONS FROM RESPONSIBILITY 1 The user of this p...

Page 13: ...sive environment The user manual must always be kept with the instrument LASER CLASSIFICATION The instrument is a laser class 2 laser product according to DIN IEC 60825 1 2014 It is allowed to use unit without further safety precautions Eye protection is normally secured by aversion responses and the blink reflex The laser instrument is marked with class 2 warning labels Please note If you return ...

Page 14: ... ladite notice avant la mise en service de votre appareil Un emploi approprié est l unique moyen de garantir un fonc tionnement efficace et de longue durée geo FENNEL Precision by tradition Contenu 1 Contenu A 2 Description B 3 Opération C 4 Consignes de sécurité D Laser à 5 points automatique Geo5P Support multi fonctions Cible magnétique 3 x AA piles alcalines Sacoche rembourrée Mode d emploi CO...

Page 15: ...isceau laserr 6 Adaptateur 1 4 7 Aimants 8 5 8 filetage pour un trépied de chantier 9 Aimants 10 Fentes pour courroies de fixation 11 Ouverture pour la fixation trou 12 Vis pour fixer l instrument sur le support multi fonctions 1 4 Screw On Off switch Output window Output window 1 3 2 Instrument fixing hand wheel Hanging hole Strong megnet Belt slot 9 11 12 10 1 4 Screw 1 4 5 8 Screw Strong megnet...

Page 16: ... l appareil est placé hors de la plage d autonivellement dans ce cas rechercher une position qui soit davantage à l horizontale Le laser Geo5P peut être monté directement sur un trépied d appareil photos ou sur un pied à une seule branche à l aide de la pièce 3 à filetage de 1 4 SUPPORT MULTI FONCTIONS Relier l appareil au support multi fonctions A présent il est possible de fixer l appareil sur u...

Page 17: ... marquer la trace désignée B Faire pivoter à nouveau l appareil de 180 par rapport au point B et marquer la trace ponctuelle du laser désignée C Si la différence de distance horizontale entre les points A B et C est inférieure à 4mm l appareil sera considéré comme étant dans les tolérances Si la différence de distance est supérieure à 4mm l appareil sera considéré comme déréglé et il faudra s adre...

Page 18: ...vec un tissu de nettoyage Quant à l optique la nettoyer avec un tissu fin comme p ex un tissu feutré de lunettes Ne jamais remiser un instrument humide dans un coffret fermé Le laisser sécher auparavant au moins pendant un jour dans un local chauffé Transport seulement dans l étui original COMPATIBILITÉ ÉLECTROMAGNETIQUE De manière générale il n est pas exclu que le niveau ne dérange d autres inst...

Page 19: ...lisation du produit 5 Le fabricant et son représentant déclinent toute responsabilité pour les dommages et le bénéfices non réalisés par suite d une manoeuvre non conforme aux instructions 6 Le fabricant et son représentant déclinent toute responsabilité pour les dommages et les bénéfices non réalisés qui decoulent d une utilisation inadéquante ou en liaison avec des produits d autres fabricants C...

Page 20: ...5 Baunatal Tel 49 561 49 21 45 Fax 49 561 49 72 34 info geo fennel de www geo fennel de Technische Änderungen vorbehalten All instruments subject to technical changes Sous réserve de modifications techniques Precision by tradition 01 2016 ...

Reviews: