22
IMPORTANT:
When assembly has been completed, the
Heating Contractor must make sure that the
ETL TECHNICAL RATING PLATE is attached
to the top panel of casing.
NOTE:
Chain must be exactly 32 inches long.
32”
B. Hold the cam in position by hand,
remove the protector (9) and replace it
with the hexagonal handle (10) at a 45
°
angle up from the center of the regulator.
C. Set the regulator knob (7) by turning
knob of regulator counter clockwise to
the red 40
°
mark which is the minimum
position (104°F).
D. Remove chain from bag and cut it 32”
long and install the hook and eyelet.
E. Secure the handle (10) by tightening nut
(11) Connect one end of the chain to the
hook and attach the hook to handle (10).
F. Tighten the rod (12) into the threaded
hole on the door (must be level with
bottom of door) and secure it, using the
nut (14), in a horizontal position so the
end of rod is facing to the right
G. Attach the 2nd hook to the other end of
the chain and connect it to the end of the
rod (12). In this position the air door (13)
is fully open.
CAUTION