Operating Instructions

 

 
The lock has a 10 button keypad , a

 C

 button and an OK button. 

 
The lock has three code levels that allow you to perform the following actions:   
1)

 

Master code:   
Open the lock; Change the master code; Set/Change/Delete the sub-master and user code; 
Select between Private and Public functions, Activate/deactivate technician code 
 

2)

 

Sub-master code:   
Open the lock; Change the sub-master code; Set/Change/Delete the user code; 
 

3)

 

User code:   
Open the lock; Change the user code 
 

4)

 

Technician code: open the lock 
 

Default Settings 

Master code = 99551133 (8 digit code)      User code =1111 (4 digit code)   
Private Mode 
 

Functions 

Before programming, select the most appropriate function for the application:   

A)

 

Private Mode or B) Public Mode 
 

Private Mode 

Note: this is the default function and is already pre-programmed into each lock. This is the most 
common mode and is used where the same code will be repeatedly used. 
To set to Private Mode:     

C

- - 11 - -OK- - Master code - -OK   

Example:   

C

- - 11 - -OK- - 99551133 - -OK   

Result:  The  lock  will  revert  back  to  default  Private  Mode,  factory  set  user  code  1111  will  now 
work until reprogrammed. 
 

Public Use 

This function is used for short term, multi user applications. The code is only used one time 
To set to Public Mode:   

C

-- 22 - -OK- - Master code - -OK 

Result:  the  lock  will  now  remain  open  until  next  user  enters  their  own  code  into  the  lock  as 
follow: 
Step 1: enter new user code -- OK    Close the locker which will now be locked 
Step 2:

 

enter user code --    The lock will now remain open until next 4 digit code is entered 

 
Note: when locked in public mode the blue light will flash every 2 seconds to indicate the locker is 
in use 