4
Product Operation Inquiry
/
Customer S82-55-328-4082
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : A-412, 579 Kyungin-Ro, Guro-Gu, Seoul, Korea (Postal Code : 08212)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (
Postal Code
: 50805)
www.qlight.com
EN-1805A
①
Installation Environment and Protection Rating
•
This product is designed for use with non-sparking explosion proof structure.
•
Please make sure to use the prduct in a environment where satisfies regulated explosion proof grading.
•
For further information, please visit our website (http://www.qlight.com).
Installation/ Mounting Hole Specifications
4-Ø7 HOLES
310
20
•
Machine holes on the mounting surface referring to the diagram below.
■
Installation
■
Mounting Hole Specifications
•
First, machine taps or holes on the mounting surface
①
.
•
The mounting hole of this product is 7mm in diameter(long hole).
•
When machining taps, fasten the bolt through the mounting hole of the product.
•
When machining holes, insert the bolt through the hole of the product,
and tighten the nut from the opposite side of the mounting surface.
(When assembling using bolt and nut, please make sure to use flat washer and
spring washer.)