4
Installation/ Mounting Hole Specifications
•
First, machine taps or holes on the mounting surface.
•
The mounting hole of this product is 6.5mm in diameter(hole).
•
When machining taps, fasten the bolt through the mounting hole of the product.
•
When machining holes, insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting surface.
•
Machine holes on the mounting surface referring to the diagram below.
.
■
Installation
■
Mounting Hole Specifications
Installation Environment and Protection Rating
• This product is designed to be explosion proof.
• Please make sure to use the product in an environment that meets the specified explosion proof rating and regulations.
• For further information, please visit our website (www.qlight.com).
Parts Definition/ Bracket Fixing Instructions
• Fix the brackets at the position where the product will be installed
• Install the brackets
①
and
②
as the installation dimension of
③
.
• Push the work light
④
in the direction of the arrow
⑤
.
• After assembling, check whether assembling is normal as shown
in the picture
⑥
.
• When the work light assembled to the bracket unstable, be careful
about damage caused by product dropping.
※
The bracket of this product is a press-fitting assembly type bracket
made of PC. It is manufactured by press-fitting type of PC material
for easy assembly/disassembly of work light.
①
Bracket
②
Bracket
②
Bracket
③
224
⑤
Arrow
⑤
Arrow
④
Work light
③
Work light
⑥
After
assembly
Bracket(PC)
Bracket(PC)
Ground wire - G/A
Power
cable
Bracket bolt(STS)
(External ground)
Side cover(Al)
Side cover(Al)
Lens(PC)
Heat sink(Al)
90
224
4-Ø6.5