background image

3

• 

Bit input mode(using external line) allows you to 

   select one of five sound options by switching on

   one of the 5 

channels (Ch1 - Ch5). 

• Total of 5 sound options are configurable.

• 

Binary input mode(using external line) allows 

  you to receive multiple inputs by using the 5 

  channels

(Ch1 - Ch5) to configure one of 30 sound 

   options.

 Total of 30 sound options are configurable. 

 Bit Input Mode

 Binary Input Mode

No. 1

2

3

4

5

0

0

0

0

0

0

1

1

0

0

0

0

2

0

1

0

0

0

3

0

0

1

0

0

4

0

0

0

1

0

5

0

0

0

0

1

0

0

0

0

0

0

1

0

0

0

0

1

2

0

0

0

1

0

29

1

1

1

0

1

30

1

1

1

1

0

Ch 1 Ch 2 Ch 3 Ch 4 Ch 5

COM

Ch1 Ch2 Ch3 Ch4 Ch5

ON(1)

OFF(0)

 The channel selection method using a 

    transistor is the same as the external 

    contact method, please refer to the 

    figure on

 the right.

 

The switch figure to the right explains

    how to wire the external contacts of a

    signal line product. If the product is not

    a signal line product, use the channel 

    selection switch attached inside the 

    product.

Binary input mode

Can select up to 30 sound options

Bit input mode

Can select up to 5 sound options

Bit/ Binary Input Method Depending on Wiring Method

• First, machine taps or holes on the mounting surface.

• The mounting hole of this product is 6mm in diameter.

• When machining taps, fasten the bolt through the mounting hole of the product.

• When machining holes, insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting surface.

• 

Install a flat washer and a spring washer to the bolt if the product can experience severe vibration and shock.

Parts Definition/ Installation/ Mounting Hole Specifications

• Machine holes on the mounting surface 

  referring to the diagram below.

■ Parts Definition/ Installation

■ Mounting Hole Specifications

2-Ø6 HOLES

Min. Ø5 CABLE ENTRY

Min. Ø5 CABLE ENTRY

2

82

2-Ø6 HOLES

5

101

2-Ø6 HOLES

Min. Ø5 CABLE ENTRY

Min. Ø5 CABLE ENTRY

2

82

2-Ø6 HOLES

5

101

QAD100H-N

QAD125H-N

Lens(PC)

Housing(ABS)

LED unit

Sound switch

Sound volume 

switch

Installation Environment and Protection Rating

• This product is designed for use with protection rating of IP65.

• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating indica-

  ted(IP65), it may cause malfunction or damage to the product.

• 

For further information, please visit our website (www.qlight.com).

Summary of Contents for S60AD/QAD Series

Page 1: ...please completely turn off the Power of the product Failure to follow this may lead to an electric shock 2 Do not install the product in locations that subjects it to excessive dust or water other th...

Page 2: ...t can be wired regardless of polarity QAD125H N Black output line is negative Ch 1 EXTERNAL CONTACT Ch 2 Ch 3 Ch 4 Ch 5 Fuse Common Power Red Amber Green Blue White White or Red Black Black Ch 1 EXTER...

Page 3: ...ptions Bit Binary Input Method Depending on Wiring Method First machine taps or holes on the mounting surface The mounting hole of this product is 6mm in diameter When machining taps fasten the bolt t...

Page 4: ...set switch no 1 to ON 1 How to select bit type sound group Sounds No 2 3 4 1 0 0 1 5 Warning Sounds 2 0 1 0 5 Special Warning Sounds 1st Group 3 0 1 1 5 Melodies 4 1 0 0 5 Alarms 5 1 0 1 5 Special Wa...

Page 5: ...one sound from 1 sound by configuring the 5 channels For sound configurations refer to the table below Bit Input Playing Built in Sound Sound Type and Combination Manual Binary input method sound conf...

Page 6: ...Sound Selection section 3 Use the terminal block on the back to select one of the five built in sounds For more information please refer to page 5 Sound Type and Combi nation for Built in Sound Bit In...

Page 7: ...ing the sky Sounder part shall not be facing the sky BEACON SIGNALING LIGHT Power cord inlet part shall not be facing the sky Power cord inlet part shall not be facing the sky SIGNAL TOWER LIGHTS HEAV...

Page 8: ...MEMO...

Page 9: ...MEMO...

Page 10: ...hina Tel 86 21 6651 7100 Fax 86 21 6315 3929 China Factory Site 2 Qidong 33 Haiyan Road Qidong High tech Industrial Development Zone Qidong Jiangsu Province China Tel 86 513 8384 9999 Fax 86 513 8384...