66
Push in the ignition button
C
(Fig. L), but do not apply too much force.
Release the ignition button as soon as a flame is visible in the combustion
chamber
D
.
After having ignited the heater, always check whether the combustion
chamber
D
is level, by sliding it slightly to the left and the right by its handle
E
(Fig. F). This should be a smooth movement. If the combustion chamber is
not level, this will cause smoke and soot to develop.
D
BURNING OF THE HEATER
After you have ignited the heater, it will take 10 to 15 minutes before you can check
whether the heater is burning well. Too high a flame may cause smoke and soot,
whereas too low a flame causes smells. Fig. Q (See at the end of the manual) shows
the minimum and maximum permissible burning heights of the flame. The flame
can be slightly adjusted with the knurled wick adjustment knob
B
(Fig. M).
Burning that is too low may be caused by:
E
insufficient fuel
(fill the tank)
E
poor fuel quality
(contact your dealer)
E
insufficient ventilation
(put window or door ajar)
E
wastage of the wick
(contact your dealer or replace the wick,
refer to section L
E
SWITCHING OFF THE HEATER
Push the OFF-button
A
. The flame will extinguish after a little while (Fig. N).
F
MALFUNCTION, CAUSES AND SOLUTIONS
If any malfunctioning cannot be solved from the directions below, please contact
your dealer.
THE HEATER DOES NOT IGNITE
E
The batteries are not positioned correctly in the holder.
Check (Fig. G).
E
There is not enough power left in the batteries for the ignition.
Replace (Fig. G).
E
You have run out of fuel from the tank or the wick has been replaced.
After having refilled and replaced the removable tank, wait for 180 minutes
before igniting the heater.
E
You are pushing the ignition button
C
with too much force.
Push it in less forcefully (Section C).
IRREGULAR FLAME AND/OR SOOT AND/OR SMELLS
E
The combustion chamber
D
has not been positioned correctly.
Use the handle
E
to put it level, until you can easily slide it slightly to the left
and to the right and the chamber is level.
E
You are using fuel which is past its ‘use by’ date.
Start every heating season with fresh fuel.
E
You are using the incorrect type of fuel.
Refer to THE RIGHT FUEL (See Section ’What you need to know in advance’).
E
Dust has gathered in the lower part of the heater.
Contact your dealer.
4
F
K
L
M
N
Summary of Contents for R 3224 X
Page 48: ...48 1 2 PVG Holding B V...
Page 50: ...50 15...
Page 51: ...51 2 5 50 2 1500 Qlima Premium Quality Fuels E E E E E E...
Page 52: ...52 E E E E E E A MANUAL A E E E C E D E E F E 8 polyfoam K G E E E E E E D B C...
Page 53: ...53 B H I J C 180 F K F J I G F H E...
Page 54: ...54 2 C L D D E F D 10 15 Q B E E E E E OFF A F E G E G E 180 E C E D E F K M N...
Page 55: ...55 E E E E E E E E E E 180 E E E E G 1 T D R20 G...
Page 56: ...56 2 H K I I...
Page 58: ...58 L 1 8 9 1 1 4 1 2 2 5 2 1 2 3 4 1 5 6 2 7 4 8 9 10 11 12 90 13 14 15...
Page 59: ...59 16 4 17 18 8mm 19 20 21 22 23 24 25 5 26 27 Premium Quality Fuels 180...
Page 129: ...129 K GARANCIJSKI POGOJI y...
Page 132: ...132 y...
Page 133: ...133 y...
Page 134: ...0 2 5cm...
Page 135: ...A B C D G E J F H I...