Remove the removable tank
G
from the heater and remove the fuel filter
(refer to Section L, Fig. L). Some drops may leak from the filter; keep a cloth
at hand. Store the fuel filter and the removable tank outside the heater.
Place the transportation cap into the position of the fuel filter (Fig. M).
Press it tight.
Always move the heater in an upright position.
O
SPECIFICATIONS
Ignition
electrical
Dimensions (mm)
width
374
Fuel
paraffin
(including base plate) depth
280
Capacity (kW) max.
3.00
height
430
Capacity (kW) min.
0.80
Accessories transportation cap
Suitable space (m
3
)
**
40-120
Fuel consumption (l/hr)
*
0.313
Mains
230V
Fuel consumption (g/hr)
*
250
-- AC/50 Hz
Burning time per tank (hr)
*
12.8
Electrical consumption
igniter 320
W
Capacity removable tank (litres) 4.0
continuous 28 W
Weight (kg)
9.5
Fuse rating
250V, 5A
Monitoring of the quality of ventilation (air renewal):
Direct measurement of the CO
2
level (NDIR CO
2
-sensor E-Guard
R
).
*
At maximum setting ** Specified values are indicative
P
WARRANTY PROVISIONS
Your heater comes with a 24-month warranty starting on the date of purchase.
Within this period all defects in material or workmanship will be repaired without
any charge. The following provisions shall apply regarding this warranty:
We expressly dismiss all other claims for damages, including consequential
damages.
Any repairs or replacements of components within the term of warranty will
not result in an extension of the term of warranty.
The warranty shall no longer apply, when the heater has been modified,
non-original parts have been used, or when it is repaired by third parties.
The warranty shall not apply to parts that are subject to normal wear, such as
the burner mat and the manual fuel pump.
The warranty shall only apply, when you present the original, dated proof of
purchase, provided no changes have been made to it.
The warranty shall not apply to damages caused by actions not in compliance
with the Directions for Use, neglect, and the use of an incorrect type of fuel,
or fuel past its use-by date. The use of incorrect fuel can even be dangerous*.
Transportation costs and the risks involved during the transportation of the
heater or heater components shall always be at the expense of the purchaser.
7
6
5
4
3
2
1
4
3
2
4
40
transportation cap
M