5–Linux Driver Software
Driver Messages
43
83840-546-00 D
CNIC Detects iSCSI Protocol Violation - Non-FATAL, Warning
bnx2i: iscsi_warning - invalid TTT
bnx2i: iscsi_warning - invalid DataSN
bnx2i: iscsi_warning - invalid LUN field
Driver Puts a Session Through Recovery
conn_err - hostno 3 conn 03fbcd00, iscsi_cid 2 cid a1800
Reject iSCSI PDU Received from the Target
bnx2i - printing rejected PDU contents
[0]: 1 ffffffa1 0 0 0 0 20 0
[8]: 0 7 0 0 0 0 0 0
[10]: 0 0 40 24 0 0 ffffff80 0
[18]: 0 0 3 ffffff88 0 0 3 4b
[20]: 2a 0 0 2 ffffffc8 14 0 0
[28]: 40 0 0 0 0 0 0 0
Open-iSCSI Daemon Handing Over Session to Driver
bnx2i: conn update - MBL 0x800 FBL 0x800MRDSL_I 0x800 MRDSL_T
0x2000
bnx2fc Driver
BNX2FC Driver Signon:
QLogic NetXtreme II FCoE Driver bnx2fc v0.8.7 (Mar 25, 2011
Driver Compiles Handshake with FCoE Offload Enabled
CNIC Device
bnx2fc [04:00.00]: FCOE_INIT passed
Driver Fails Handshake with FCoE Offload Enabled CNIC Device
bnx2fc: init_failure due to invalid opcode
bnx2fc: init_failure due to context allocation failure
bnx2fc: init_failure due to NIC error
bnx2fc: init_failure due to completion status error
bnx2fc: init_failure due to HSI mismatch
NOTE
The driver needs to be configured to consider certain violation to treat as
warning and not as a critical error.
Summary of Contents for 8400 Series
Page 390: ......