5.
Finally, test by logging into the front end node, and from the front end node
to a compute node, as follows:
$ ssh frontend_node_name
$ ssh compute_node_name
For more information, see the man pages for
ssh(1)
,
ssh-keygen(1)
,
ssh-add(1)
, and
ssh-agent(1)
.
Process Limitation with
ssh
Process limitation with
ssh
is primarily an issue when using the
mpirun
option
-distributed=off
. The default setting is now
-distributed=on
; therefore, in
most cases,
ssh
process limitations will not be encountered. This limitation for the
-distributed=off
case is described in the following paragraph.
MPI jobs that use more than 10 processes per node may encounter an
ssh
throttling mechanism that limits the amount of concurrent per-node connections
to 10. If you need to use more processes, you or your system administrator must
increase the value of
MaxStartups
in your
/etc/ssh/sshd_config
file.
Checking Cluster and Software Status
ipath_control
IB status, link speed, and PCIe bus width can be checked by running the program
ipath_control
. Sample usage and output are as follows:
$ ipath_control -iv
QLogic OFED.
VERSION yyyy_mm_dd.hh_mm_ss
0: Version: ChipABI
VERSION
, InfiniPath_QLE7340, InfiniPath1
VERSION
, SW Compat 2
0: Serial: RIB0935M31511 LocalBus: PCIe,5000MHz,x8
0,1: Status: 0xe1 Initted Present IB_link_up IB_configured
0,1: LID=0x23 GUID=0011:7500:005a:6ad0
0,1: HRTBT:Auto LINK:40 Gb/sec (4X QDR)
Summary of Contents for OFED+ Host
Page 1: ...IB0054606 02 A OFED Host Software Release 1 5 4 User Guide...
Page 14: ...xiv IB0054606 02 A OFED Host Software Release 1 5 4 User Guide...
Page 22: ...1 Introduction Interoperability 1 4 IB0054606 02 A...
Page 96: ...4 Running MPI on QLogic Adapters Debugging MPI Programs 4 24 IB0054606 02 A...
Page 140: ...6 SHMEM Description and Configuration SHMEM Benchmark Programs 6 32 IB0054606 02 A...
Page 148: ...8 Dispersive Routing 8 4 IB0054606 02 A...
Page 164: ...9 gPXE HTTP Boot Setup 9 16 IB0054606 02 A...
Page 176: ...A Benchmark Programs Benchmark 3 Messaging Rate Microbenchmarks A 12 IB0054606 02 A...
Page 202: ...B SRP Configuration OFED SRP Configuration B 26 IB0054606 02 A Notes...
Page 206: ...C Integration with a Batch Queuing System Clean up PSM Shared Memory Files C 4 IB0054606 02 A...
Page 238: ...E ULP Troubleshooting Troubleshooting SRP Issues E 20 IB0054606 02 A...
Page 242: ...F Write Combining Verify Write Combining is Working F 4 IB0054606 02 A Notes...
Page 280: ...G Commands and Files Summary of Configuration Files G 38 IB0054606 02 A...
Page 283: ......