10–Converged Network Adapter Interactive Commands
Loopback Test
SN0054667-00 C
10-115
Display Test Parameters
6. Loopback Test
<port selection>
2. FCoE
1. Display Test Parameters
From the Loopback Test menu, select the
Display Test Parameters
option to
view the loopback test parameters. For example:
------------------------------------------------------------------------------
HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20
------------------------------------------------------------------------------
--------------------
Diagnostics Settings
--------------------
Data Pattern : Random
Data Size (Bytes) : 8
Number of tests (1-65535): 10000
Test Increment(1-65535) : 1
Abort On Error : Ignore
Test Continuous : OFF
Loopback Type : Special Echo FCoE Loopback (252) in size
------------------------------------------------------------------------
Reset Test Parameters
6. Loopback Test
<port selection>
2. FCoE
2. Reset Test Parameters
From the Loopback Test menu, select the
Reset Test Parameters
option to reset
the loopback test parameters to their default values.
lists the default
loopback test values.
Table 10-1. Default Loopback Test Parameter Values
Parameter
Default Value
Data Pattern
Random
Data Size (Bytes)
8
Number of tests
10,000
Test Increment
1
Abort On Error
Ignore
Test Continuous
OFF
Loopback Type
Special Echo FCoE Loopback (252) in size
Summary of Contents for QConvergeConsole CLI 2400 Series
Page 1: ...SN0054667 00 C User s Guide QConvergeConsole CLI 2400 2500 3200 8100 8200 Series...
Page 20: ...xx SN0054667 00 C User s Guide QConvergeConsole CLI 2400 2500 3200 8100 8200 Series...
Page 28: ...1 System Requirements Supported QLogic Adapters 1 4 SN0054667 00 C...
Page 134: ...6 iSCSI Noninteractive Commands vpd Display VPD Information 6 28 SN0054667 00 C...
Page 204: ...9 Fibre Channel Interactive Commands Exit 9 46 SN0054667 00 C...
Page 365: ......