3 – Troubleshooting
System Configuration Problem Checklist
3-2
PX2454601-00 C
Q
3.3
System Configuration Problem Checklist
Check the motherboard for proper configuration (see the appropriate installation
section for more information.
Check the documentation supplied with your computer, or contact your computer
dealer to determine if your motherboard requires special configuration.
3.4
Fibre Channel Problem Checklist
■
Were all of the FC devices powered up before you powered up the PC?
■
Check that all cables are properly connected.
■
Have you configured your RAID controller using the utilities provided by the
manufacturer?
■
Some Fibre Channel switches support zoning. Make sure that your switch is
configured correctly.
■
Make sure that data rate setting on the QLE2360/2362
matches the target device.
For example, if the QLE2360/2362
is set to 2 Gb, set the target device to 2 Gb
.
■
If you are using a RAID box, modify the following settings in
Fast!
UTIL:
❑
Login Retry Count = 60
❑
Port Down Retry Count = 60
❑
Execution Throttle = 100
3.5
Troubleshooting
The QLogic knowledge database contains troubleshooting information for the
QLogic SANblade HBAs. Access the database from the QLogic website at:
www.qlogic.com/support/knowledge_base.asp