background image

Switch Command Line Interface

Groups and Commands

1-24

D000103-000  E

sessionTimeoutEnable

Enable the idle timeout for the CLI session.

Syntax:

Options:

Sample Output:

NOTES:

 Enables the idle timeout for the current CLI session. This value does not 

persist across instances of the session (i.e., with each log on, it defaults back to the 
system default value).

loginMsgGet

Displays the CLI login message for this device.

Syntax:

Options:

Sample Output:

NOTES:

 Displays the current login welcome message for the CLI.  This message 

can be customized with the loginMsgSet command.

loginMsgSet

Set the CLI login message for this device.

Syntax:

sessionTimeoutEnable

None.

-> sessionTimeoutEnable

Enabled session idle timeout.

loginMsgGet

None.

-> loginMsgGet

Welcome message: Be certain to logout when you are finished using the 
CLI.

loginMsgSet [message] [-clear]

Summary of Contents for QLogic 12000 Series

Page 1: ...D000103 000 E QLogic 12000 Series InfiniBand Switches and Directors CLI Reference Guide Version 6 0...

Page 2: ...at any time without notice Applications described in this document for any of these products are for illustrative purposes only QLogic Corporation makes no representation nor warranty that such applic...

Page 3: ...formation vii Knowledge Database vii 1 Switch Command Line Interface Overview 1 1 Commands and Functional Groups 1 2 Online Help 1 4 Keyboard Shortcuts 1 4 Accessing the CLI 1 4 Groups and Commands 1...

Page 4: ...iv D000103 000 E QLogic 12000 Series InfiniBand Switches and Directors CLI Reference Guide...

Page 5: ...formation CAUTION indicates the presence of a hazard that has the potential of causing damage to data or equipment WARNING indicates the presence of a hazard that has the potential of causing personal...

Page 6: ...s the year Topic titles between quotation marks identify related topics either within this manual or in the online help which is also referred to as the help system throughout this document License Ag...

Page 7: ...awards a certificate identifying the student as a Certified Professional The training professionals at QLogic may be reached by e mail at training qlogic com Contact Information Please feel free to c...

Page 8: ...Preface Technical Support viii D000103 000 E...

Page 9: ...sing Telnet and secure shell SSH of The 12300 chassis The SEEB module s of the 12800 series Accessing the CLI through the serial port does not require a login and password unless configured to do so a...

Page 10: ...f available commands can be accessed by typing list To keep the list short the commands are grouped into functional groups which are General General commands for user management and CLI configuration...

Page 11: ...ameters required to access the switch from an SNMP manager CaptureInfo Providescommandsforcapturingswitch specificinformationforthepurposes of analysis and debugging To list commands within afunctiona...

Page 12: ...Shortcuts The CLI keeps a history of recently executed commands This history is available via the Up and Down arrow keys Users may edit the current command with the Left and Right arrow keys Tab compl...

Page 13: ...3 The system prompts for a password The CLI has the following default passwords Operator access operpass Administrator access adminpass Type the appropriate password and press Enter The system respond...

Page 14: ...re specific command information the user would execute the help COMMAND NAME command General help Displays help information for a specific command Syntax Options Sample Output NOTES General Help Type...

Page 15: ...e g command Text outside the and characters is the actual text that needs to be entered When there is more than one choice the options are specified within and characters where the options are separa...

Page 16: ...help for all commands Use list noprompt to display the list of command groups history Displays the command history for this session Syntax Options Sample Output reboot 12300 Reboots the device Syntax...

Page 17: ...l device from telnet ssh etc you will have to reconnect after rebooting Default no arguments reboots local device disruptively after prompt See also resetCard showInventory reboot 12800 Series Reboots...

Page 18: ...ct after rebooting Default no arguments reboots local device disruptively after prompt See also resetCard showInventory killCliSession Terminates an existing CLI session Syntax Options now Does not pr...

Page 19: ...for the user to enter login information For each session the following information is displayed user username of the logged in user role security role of the user index internal session index logged...

Page 20: ...s command swaps two commonly used bindings which allow the user to use the backspace and delete keys properly without having to adjust their terminal settings Backspace and delete swapping is persiste...

Page 21: ...s the terminal width used for text formatting purposes Note that not all commands adhere to this setting prompt Set the CLI prompt global for all active CLI sessions Syntax Options Sample Output NOTES...

Page 22: ...tivity is displayed otherwise the case sensitivity is turned on or off depending on the specified option When case sensitivity is on the CLI input must match the exact character case lower and upper c...

Page 23: ...f there are multiple arguments they are separated by spaces rlogin Creates I O terminal to local cards Syntax Options Sample Output NOTES This command allows users to open a terminal to local I O devi...

Page 24: ...cmd is an alias of rlogin See also hostShow resetCard Reboot a specific slot in the chassis Syntax Options Sample Output NOTES If you reset the switch you are connected to you will have to reconnect Y...

Page 25: ...Output user Change user accounts Syntax Options Sample Output NOTES Use this command to change to the operator account or to the admin account The minimum password length is 8 characters The maximum...

Page 26: ...le Output passwd username username Name of the user whose password needs to be changed passwd operator1 User password changed successfully userAdd role username password role Can be either admin or op...

Page 27: ...account Syntax Options Sample Output userListShow List all user accounts for this device Syntax Options Sample Output userRem username username Name of the user to be removed userRem Bob User deleted...

Page 28: ...use the u option to manage keys for other users sshKey cmd u username input show Displays the SSH public keys in the users authorized_keys file add key Add key to the users authorized_keys file Must...

Page 29: ...ing modes should become active 0 Username and password required 1 Password is not required 2 Username password are not required 3 LDAP Authentication When usernames are disabled all users will be logg...

Page 30: ...e authentication idleTimeoutGet Retrieves the UI idle timeout value Syntax Options Sample Output NOTES Displays the system idle timeouts for the GUI and CLI interfaces If set to zero the timeout is di...

Page 31: ...Disables the idle timeout for the current CLI session This value does not persist across instances of the session i e each time you log on it will default back to the system default value idleTimeout...

Page 32: ...lts back to the system default value loginMsgGet Displays the CLI login message for this device Syntax Options Sample Output NOTES Displays the current login welcome message for the CLI This message c...

Page 33: ...s Sample Output NOTE The login name is an arbitrary string displayed prior to a user attempting a login to a new CLI session This command displays the current value of this string loginNameSet Modify...

Page 34: ...current serial authentication status Syntax Options Sample Output NOTES Displays whether user login and authentication is required on the serial console of the system serialAuthSet Enable or disable...

Page 35: ...rfaces to this device Syntax Options Sample Output NOTES There are several access methods for this device With no arguments this command displays which access methods are available and whether each me...

Page 36: ...ss method Any access method supported by the device but not listed here cannot be configured and is always enabled genPost Displays General POST results and runs tests Syntax Options Sample Output NOT...

Page 37: ...le setting Syntax Options Sample Output IpoIbConfigEnable Enable IPoIB feature Syntax Options Sample Output IpoIbConfigDisable Disables the IPoIB feature Syntax Options Sample Output IpoIbConfigShow N...

Page 38: ...address and associated network mask Syntax Options Sample Output NOTES IPoIB must be enabled to display these fields IpoIbAddressSetIPv6 Changes the IPoIB IPv6 address and netmask Syntax IpoIbAddressS...

Page 39: ...d e f g h where embedded 0s can be shortened for example a b g h The netMaskLen is a value between 0 and 128 inclusive IpoIbAddressShowIPv6 Displays the IPoIB IPv6 Address and associated netmask setti...

Page 40: ...arning error information If an error warning is detected this command automatically provides verbose information hwMonitor Displays current port states fan speeds temperatures and voltages Syntax Opti...

Page 41: ...204 F204 6840 Max Temp 60C Management Module 202 Legend P pres abs TMP Temperature VLT Voltage E Err W Warn X Err Warn found Sample 2 hwMonitor 0 System monitor Uptime 0 days 4 hours 57 minutes 2 seco...

Page 42: ...NOTES New node name must be enclosed in quotes Node name must be less than 64 characters setIBNodeDescFormat Changes the IB Node SMA description format modifier Syntax Options d Show the default Node...

Page 43: ...The all parameter performs this command against all available slots for the device setIBNodeDescFormat Format 0 fruInfo slot all slot Slot that you wish to display EEProm contents Defaults to 0 chassi...

Page 44: ...eters will display all currently occupied card slots showInventory Displays a detailed list of all hardware within the chassis Syntax Options chassisQuery master slave slot showType type card_type ign...

Page 45: ...ows the user to set show the chassis system contact Syntax Options MasterMM202 showInventory ___________________________________ Leaf 101 GUID 00066A00EC002712 Manufacturer Id 00066A Manufacturer Name...

Page 46: ...NOTES If the system name is not specified the current system name is displayed setSystemLocation Allows the user to set show the chassis system location Syntax Options Sample Output NOTES If the syste...

Page 47: ...teShow Displays the OOB LAN IP routes Syntax ifShow ifName ifName The network interface name ifShow sbe0 unit number 0 Flags 0x8063 UP BROADCAST MULTICAST ARP RUNNING Type ETHERNET_CSMACD Internet add...

Page 48: ...0 1 3 2 18966 sbe0 0 0 0 0 172 26 3 35 3 0 0 sbe0 127 1 0 0 127 1 1 2 101 0 0 sbe1 127 2 0 0 127 2 0 1 101 0 0 sbe1 172 26 0 0 172 26 3 35 101 0 0 sbe0 172 26 0 0 172 26 3 19 101 1 0 sbe0 ROUTE HOST...

Page 49: ...0 254 icmp_seq 0 time 0 ms 64 bytes from 172 26 0 254 icmp_seq 1 time 0 ms 64 bytes from 172 26 0 254 icmp_seq 2 time 0 ms 64 bytes from 172 26 0 254 icmp_seq 3 time 0 ms 64 bytes from 172 26 0 254 ic...

Page 50: ...ess and network mask Syntax Options Sample Output NOTES Changing the chassis IP address will drop the connection to the CLI if not using the console port and may cause the device to become unreachable...

Page 51: ...the chassis IPv6 address may drop the connection to the CLI if not using the console port and may cause the device to become unreachable This command does not affect link local or autoconfigured addre...

Page 52: ...ct link local or manually configured addresses autoConfIPv6Disable Disables IPv6 address autoconfiguration Syntax Options Sample Output NOTES Prevents prefix learning from attached routers and does no...

Page 53: ...faultRoute Displays the default gateway IP address Syntax Options Sample Output NOTES This is the IP address for the default gateway to route packets from the OOB mangement port to an external network...

Page 54: ...le Output hostShow Displays a list of remote hosts names internet address and alias es Syntax setDefaultRoute h ipaddress h ipaddress The default gateway IP address in dotted decimal format xxx xxx xx...

Page 55: ...Switch Command Line Interface Groups and Commands D000103 000 E 1 47 Options None...

Page 56: ...lot13 127 1 0 13 slot14 127 1 0 14 slot15 127 1 0 15 slot16 127 1 0 16 slot17 127 1 0 17 slot18 127 1 0 18 slot19 127 1 0 19 slot20 127 1 0 20 slot21 127 1 0 21 slot22 127 1 0 22 slot23 127 1 0 23 slo...

Page 57: ...the lease data from the server dhcpDisable Disable the DHCP client and release any acquired IP address Syntax Options Sample Output NOTES Any DHCP acquired IP address will be released The interface wi...

Page 58: ...02 dhcpShow Client state BOUND Assigned IP address 172 26 3 35 Client subnet mask 255 255 240 0 DHCP server 172 26 1 20 Default IP router 172 26 0 1 Client lease duration 518400 secs 421299 remaining...

Page 59: ...s installed limit 32 chars e 1 or 0 1 enable the DNS resolver 0 disable the DNS resolver dnsParamsSet e 0 MasterMM202 dnsParamsShow DNS Resolver Disabled DNS Server Address xxx xxx xxx xxx Local Domai...

Page 60: ...eSlot Updates the firmware on a specific line card Syntax fwUpdate host user password dir filename host The name of the host where the firmware file resides user The FTP user name password The FTP use...

Page 61: ...name of the host where the firmware file resides user The FTP user name password The FTP user password dir After logging in the directory to cd to filename The name of the firmware file fwUpdateSlot...

Page 62: ...prompted for the names of each file for each line card type present The system can save the values entered as defaults for future firmware updates fwListFiles Lists the contents of the firmware direct...

Page 63: ...rmation for a specific release Syntax fwShowUpdateParams Firmware update ftp configuration settings host 0 0 0 0 user ftp password ftp directory filename management filename evic filename fvic fwSetUp...

Page 64: ...or automated systems to determine if a SCP firmware push was successful or not fwVersion Displays the firmware versions for a unit Syntax Options key feature Displays information for a particular feat...

Page 65: ...n 5 0 0 0 73 Firmware build 5_0_0_0_73 Firmware BSP xt3 MBC Version None Bootrom Version 5 0 0 0 57 bootQuery slot active alternate all slot Slot number active Displays the version of the active firmw...

Page 66: ...slot number using the next boot image i index The index of the boot image to be used next alternate Chooses the alternate image to be used next version version Chooses a specific version to be the ima...

Page 67: ...yntax Options Sample Output 1 smControl start stop restart status Start Start the SM Stop Stop the SM restart Restarts the SM status Prints out the SM Status smControl start Starting the SM smConfig q...

Page 68: ...0 GUID 0x00066a00da000000 172 26 2 2 MM 1 Ch Node 0 00066a000600013c 2 ports 24 path Port GUID S LID LMC _VL_ __MTU__ _WIDTH_ ____SPEED____ CAP_MASK N P 0 00066a000600013c 4 LID 0001 LMC 0000 8 8 2k 2...

Page 69: ...s allows persistent failovers that do not automatically fail back by configuring the elevated priority to be higher than all normal priorities This feature is effectively disabled when set to the defa...

Page 70: ...the subnet manager that is currently running and will not be persistent smForceSweep Force a fabric sweep by the embedded subnet manager Syntax Options Sample Output NOTES Use this command to force a...

Page 71: ...Multicast Groups join state key F Full N Non S SendOnly Member 0xff12601bffff0000 00000001ffffd5bb c001 qKey 0x00000000 pKey 0xFFFF mtu 4 rate 3 life 19 sl 0 0x0011750000ffd5bb F 0xff12401bffff0000 0...

Page 72: ...ding subscription table in the embedded subnet manager Syntax Options smShowServices There is 1 Service Records Service ID 0x1100D03C34834444 Service GID 0xFE80000000000000 00066A000600013C Service P_...

Page 73: ...Subscriber Record ID 0x00000001 Subscriber Inform Info GID 0x0000000000000000 0000000000000000 Start LID 0xFFFF End LID 0x0000 Is Generic Yes Subscribe Subscribe Type All Types Trap Number 0x0040 Queu...

Page 74: ...gn 8 LIDs per endport The allowable LMC values are between 0 and 7 inclusive The subnet manager must be running as MASTER to display the LMC value smShowMasterLid Display the LID of the subnet manager...

Page 75: ...ly set the default switch lifetime of the subnet manager Syntax smShowLidMap SM is currently in the MASTER state with Topology Pass count 341 Lid 0x0001 guid 0x00066a000600013c pass 341 QLogic 12300 G...

Page 76: ...tax Options Sample Output NOTES Use this command to display the maximum lifetime that a packet may remain at the head of a virtual lane transmission queue before it is discarded by a switch Packet lif...

Page 77: ...port enters a stalled state after dropping packets The subnet manager must be running to display or to dynamically set VLStall Changes to VLStall with the smVLStall command only affect the currently r...

Page 78: ...e The subnet manager must be running to display PKeys smInfoKey Set the subnet manager key SMInfo value Syntax Options smShowSMParms SM priority is set to 4 SM LMC is set to 0 SM sweep rate is set to...

Page 79: ...portInfo value Syntax Options Sample Output NOTES Use this command to set the SM management key SM must be offline and mkey value is up to 8 byte hex The subnet manager must be running to display the...

Page 80: ...alues are 2 2 5GB 3 10GB 4 30GB 5 5GB 6 20GB 7 40GB 8 60GB 9 80GB 10 120GB Valid Values for SL are 0 to 0xF Valid Values for QKEY are 0 to 0xFFFFFFFF Valid Values for FlowLabel are 0 to 0xFFFFF clear...

Page 81: ...The subnet manager must be running to display default multicast group information smSubnetSize Set display the subnet size for the subnet manager Syntax Options Sample Output NOTES Use this command t...

Page 82: ...sweep smTopoAbandonThresh Set display the max consecutive times the SM can abandon a sweep due to too many errors Syntax Options Sample Output NOTES The subnet manager must be running to display this...

Page 83: ...ger must be running to display this information smNonRespDropTime Displays the seconds to wait before dropping a non responsive node Syntax Options Sample Output smMaxRetries 3 Set max retries to 3 sm...

Page 84: ...evel Syntax Options Sample Output NOTES Levels 1 WARN 2 INFINI_INFO 3 INFO 4 VERBOSE 5 DEBUG2 6 DEBUG3 7 TRACE The subnet manager SM must be running to use this command Changes made with this command...

Page 85: ...1 or 2 The Subnet manager must be running to use this command Changes made with this command will only affect the currently running SM and will will be forgotten if the FM is restarted or the chassis...

Page 86: ...be forgotten if the FM is restarted or the chassis is rebooted To make persistent changes edit the FM XML config file smMcLidTableCap Displays the limit of the multicast LIDs that are available for a...

Page 87: ...MasterPingFailures Displays the number of allowable master ping failures Syntax Options Sample Output NOTES Value must be between 2 and 5 The subnet manager must be running to display this information...

Page 88: ...l sync interval currently set to 15 minutes SM DB SYNCHRONIZATION interval set to 900 seconds 2 SM s in fabric MASTER SM node at QLogic 12300 GUID 0x00066a00d90003fa LID 0x0008 PortGuid 0x00066a00d900...

Page 89: ...17 536870 usec Index 4 PLT Value 18 1073741 usec Index 5 PLT Value 18 1073741 usec Index 6 PLT Value 18 1073741 usec Index 7 PLT Value 18 1073741 usec Index 8 PLT Value 19 2147483 usec Index 9 PLT Val...

Page 90: ...nning to display this information smTrapThreshold Display the port auto disable urgent trap threshold value in minutes Syntax Options Sample Output NOTES When enabled ports generating urgent traps at...

Page 91: ...uch messages to be logged at the NOTICE level A value greater than zero will cause the priority of any subsequent messages to be logged at the INFO priority The subnet manager must be running to displ...

Page 92: ...eded its urgent trap threshold This command is not available unless the subnet manager is in Master mode smShowCounters Display various statistics and counters maintained by the subnet manager Syntax...

Page 93: ...IS SWEEP LAST SWEEP TOTAL SM State transition to DISCOVERY 0 0 2 SM State transition to MASTER 0 0 1 SM State transition to STANDBY 0 0 1 SM State transition to INACTIVE 0 0 0 Total transmitted SMA Pa...

Page 94: ...e manager PM Syntax Options Sample Output pmShowRunningTotals Displays Running Total Counters for the performance manager PM for all ports in a fabric Syntax Options Sample Output bmPriority Display t...

Page 95: ...lay the priority pmPriority Display the priority of the embedded performane manager Syntax Options Sample Output NOTES The priority of the Performance Manager PM determines which PM will become the ma...

Page 96: ...store the normal priorities of the SM BM and PM smResetConfig Resets the XML configuration for the embedded subnet manager ESM to factory defaults This command is only available on the Master chassis...

Page 97: ...f Applications which may be used in Virtual Fabrics Applications defined here are available for use in all FM instances Additional Applications may be defined here or per FM instance Applications spec...

Page 98: ...Switch Command Line Interface Groups and Commands 1 90 D000103 000 E noprompt flag to send all output to the screen at once This command is only available on the Master Chassis management card...

Page 99: ...26 31 236U Thread CPU1 0x1 Fcpi Target Device 3 d94 p3 NPort Id 0x0106d3 Connection Restored W 2006 10 04 20 26 31 246U Thread Log 0x8fdab3b0 Log Unable to Send Trap 523 Bad 65535 W 2006 10 04 20 26 3...

Page 100: ...lears the log file Syntax Options Sample Output NOTES This command deletes all entries in the log file logConfigure Configures the log settings Syntax Options logClear noprompt noprompt delete all log...

Page 101: ...t also be active in Preset for log messages to be processed for a device Syslog Configure the syslog host ip address and port logConfigure Type Q or X to exit Please enter the number corresponding to...

Page 102: ...facility to use in the messages The facility value assignments are logResetToDefaults noprompt noprompt Restore the defaults without prompting the user logResetToDefaults Log configuration has been r...

Page 103: ...1 user 2 mail 3 daemon 4 auth 5 syslog 6 lpr 7 news 8 uucp 9 cron 10 authpriv 11 ftp 12 ntp 13 audit 14 alert 15 clock 16 local0 17 local1 18 local2 19 local3 20 local4 21 local5 22 local6 23 local7...

Page 104: ...01 Configurable devices index name D F E A W P C I P N 1 2 3 4 5 1 Ram X X X X X X 3 Console X X X X X X 5 Syslog X X X X X X Configurable presets index name state 1 Dump Enabled 2 Fatal Enabled 3 Err...

Page 105: ...guration by sending CSM message s to registered Syslog servers e Send Error severity CSM test message to Syslog w Send Warning severity CSM test message to Syslog n Send Warning severity CSM test mess...

Page 106: ...ES License keys unlock various product software features addKey Add a license key Syntax Options Sample Output removeKey Remove a license key Syntax showKeys None showKeys Key number 1 Key XX7P91 2V9H...

Page 107: ...nd a list of available keys will be displayed The keys are shown along with an associated number At the prompt enter the number of the key you wish to remove None removeKey Key number 1 Key XX7P91 XXX...

Page 108: ...n cleared noprompt Does not give the user a Continue prompt for each page of display cols X Sets the number of columns to be displayed per line port X Specifies a port s to display leaf X 12800 only D...

Page 109: ...ne ErrRecovery The number of times the link error recovery proccess happened successfully LinkDowned The number of times the link error recovery process failed RcvErrors Number of errors received on t...

Page 110: ...data packets received by the port not including flow control packets Receive Words The number of data words received by the port not including flow control and VCRC data ismPortCounters clear active...

Page 111: ...error recovery process failures RcvErrors Number of errors received on the port RmtPhysErr Number of remote physical errors received on the port TxDiscards Number of port transmit discards InPKeyViol...

Page 112: ...ID Port 0001 18 L101P18 0003 22 L101P22S105BP15 0004 21 L101P21S105AP21 0005 21 L101P21S105AP21 0006 21 L101P21S105AP21 0009 19 L101P19S105BP18 0014 0 001a 21 L101P21S105AP21 0027 20 L101P20S105BP17 S...

Page 113: ...01P18 19 L101P19S105BP18 21 L101P21S105AP21 c001 18 L101P18 19 L101P19S105BP18 21 L101P21S105AP21 c002 19 L101P19S105BP18 21 L101P21S105AP21 c003 18 L101P18 19 L101P19S105BP18 21 L101P21S105AP21 c004...

Page 114: ...or backwards compatibility The ismPortSetWidth command is preferred This command ONLY works on platforms enable Enable the auto clear feature disable Disable the auto clear feature warn Generate warni...

Page 115: ...n This command will enable 8X link aggregation so that Internal AND External switching will be at 8x Each 8X port is 2 aggregated 4x ports i e a DUO where one will be reported as an 8x port and the ot...

Page 116: ...ther similarly configured port to establish a link Calling this function without a speed designator displays the current values of the port Calling this function with the bounce option disruptively br...

Page 117: ...enable option displays the current value of the port s When disabling ports only cable ports are disabled ismPortDisable Allows the user to enable or disable ports Syntax Options Sample Output ismPort...

Page 118: ...plays the current values Calling this function with the bounce option disruptively brings active links down then back up so the links use the new setting immediately Otherwise the new setting is used...

Page 119: ...alling this function without an enable8xBit will display the ports current values Calling this function with the bounce option disruptively brings active links down and back up so the links use the ne...

Page 120: ...al port link speeds Syntax Options Sample Output 1 ismChassisSetMtu L01P01 MTUCap 4 2048 bytes VLCap 4 8 VLs L01P02 MTUCap 4 2048 bytes VLCap 4 8 VLs L01P03 MTUCap 4 2048 bytes VLCap 4 8 VLs L01P04 MT...

Page 121: ...atistic thresholds Syntax Options Sample Output NOTE The following are the available port statics thresholds 1 portXmitData 32 bit data words transmitted 2 portRecvData 32 bit data words received ismS...

Page 122: ...nd was invalid 14 portPKeyViolOut PKey outbound was invalid 15 portRawViolIn raw inbound packet discarded 16 portRawViolOut raw outbound packet discarded 17 portLocalLinkInteg link integrity errors 18...

Page 123: ...PKeyViolIn portPKeyViolOut portRawViolIn portRawViolOut portLocalLinkInteg portExcBufferOverrun portRelayedVL15Dropped portLocalVL15Dropped portNonSMPDropped ismRemoveStateDump Removes switch ASIC sta...

Page 124: ...umps Syntax Options Sample Output ismShowStateDump 12300 Shows contents of switch ASIC state dumps Syntax ismRemoveStateDump all ismRemoveStateDump None ismShowStateDump all leaf X spine X all Removes...

Page 125: ...ortName option will display its current values Calling this function with the bounce option disruptively brings active links down and back up so the links use the new setting immediately Otherwise the...

Page 126: ...ve links down and back up so the links use the new setting immediately Otherwise the new setting will be used the next time links retrain ismIslSetWidth View Set Unset chassis link width except extern...

Page 127: ...is function with the bounce option disruptively brings active links down and back up so the links use the new setting immediately Otherwise the new setting will be used the next time links retrain ism...

Page 128: ...all installed QSFPs on leaf xxx LxxxPyy display info for QSFP installed on leaf xxx port yy Cableyy display info for QSFP installed on port yy 12300 only QSFP information may not be available for DDR...

Page 129: ...Commands D000103 000 E 1 121 ismIslBounce Bounce only the enabled internal ports Syntax Options Sample Output ismPortBounce Bounce enabled port s Syntax Options Sample Output ismIslBounce None ismIsl...

Page 130: ...tem time will be printed out timeZoneConf Display configure the time zone setting Syntax Options Sample Output time S ipaddr T hhmmss mmddyyyy S ipaddr Sets the NTP Server IP address T hhmmss mmddyyyy...

Page 131: ...Sunday of October the command would be timeDSTConf 1 1 4 4 1 10 timeDSTConf sw sd sm ew ed em sw Start which valid values 1 1st 2 2nd 3 3rd 4 4th 5 5th sd Start day valid values 1 Sunday 2 Monday 3 Tu...

Page 132: ...timeout value in whole seconds as the only argument The default settings is 2 seconds The NTP timeout value is not used on line cards or slave CMUs timeNtpRefreshTime Display or set the delay between...

Page 133: ...ommand displays the current NTP refresh time which is the delay in seconds between attempts to sync the clock via NTP This value can be configured by using this same command with the new refresh time...

Page 134: ...isplayed If options are entered then the corresponding community string is changed snmpTargetAddr Displays and allows the changing of the snmpTargetAddrTable entries Syntax snmpCommunityConf r readonl...

Page 135: ...ed decimal form p Port The target port to send traps and information t Timeout The time to wait for an information response r Retry count The number of re send attempts for information l Tag list Indi...

Page 136: ...getParamsMPModel v1 params 0 rfc2573t snmpTargetParamsMPModel v2 params 1 rfc2573t snmpTargetParamsMPModel v3 params 3 rfc2573t snmpTargetParamsSecurityModel v1 params 1 rfc2573t snmpTargetParamsSecur...

Page 137: ...ex value For more details on the snmpNotifyFilterTable see SNMP NOTIFICATION MIB RFC 2573 snmpNotify Displays the snmpNotifyTable entries Syntax Options snmpNotifyFilter show show Displays the content...

Page 138: ...g interfaces rfc2233 rfc2573n snmpNotifyTag rmon rfc1757 rfc2573n snmpNotifyTag snmp rfc1907 rfc2573n snmpNotifyTag tms tmscom rfc2573n snmpNotifyType switch 1 snmpSystem show edit n sysName l sysLoca...

Page 139: ...rrently supported snmpUsrSec add show edit delete name a algo key add add an entry to the V3 user table show show entries in the V3 user table edit modify an entry in the V3 user table delete remove a...

Page 140: ...ns NOTE This command is intended for support personnel captureFw Display firmware information for this device Syntax Options NOTE This command is intended for support personnel captureLog Display log...

Page 141: ...onnel captureIsm Display Infiniband switch information for this device Syntax Options NOTE This command is intended for support personnel captureChassis Display chassis information for this device Syn...

Page 142: ...s device Syntax Options NOTE This command is intended for support personnel captureSnmp Display SNMP information for this device Syntax Options NOTE This command is intended for support personnel capt...

Page 143: ......

Page 144: ...owners Information supplied by QLogic Corporation is believed to be accurate and reliable QLogic Corporation assumes no responsibility for any errors in this brochure QLogic Corporation reserves the...

Reviews: