5 – Diagnostics/Troubleshooting
Power-On Self Test Diagnostics
5-4
59225-00 B
S
5.2.1.1
Internal Firmware Failure Blink Pattern
An internal firmware failure blink pattern is 2 blinks followed by a two second
pause. The 2-blink error pattern indicates that the firmware has failed, and that the
switch must be reset. Momentarily press and release the Maintenance button to
reset the switch.
5.2.1.2
System Error Blink Pattern
A system error blink pattern is 3 blinks followed by a two second pause. The
3-blink error pattern indicates that a POST failure or a system error has left the
switch inoperable. If a system error occurs, contact your authorized maintenance
provider. Momentarily press and release the Maintenance button to reset the
switch.
5.2.1.3
Configuration File System Error Blink Pattern
A configuration file system error blink pattern is 4 blinks followed by a two second
pause. The 4-blink error pattern indicates that a configuration file system error has
occurred, and that the configuration file must be recreated. Refer to
“Recovering a
Switch” on page 5-11
for more information.
2 seconds
2 seconds
2 seconds
Summary of Contents for SANbox 1400 Series
Page 26: ...1 Introduction Technical Support 1 18 59225 00 B S Notes...
Page 46: ...3 Planning Fabric Management 3 10 59225 00 B S Notes...
Page 88: ...A Specifications Regulatory Certifications A 6 59225 00 B S Notes...
Page 200: ...B Command Line Interface Zoning Command B 112 59225 00 B S Notes...
Page 206: ...SANbox 1400 Series Fibre Channel Switch Installation Guide Glossary 6 59225 00 B S Notes...
Page 214: ...SANbox 1400 Series Fibre Channel Switch Installation Guide Index 8 59225 00 B S Notes...