Zoning Window
SANbox-8/16 Switch Management
User’s Manual
59010-06 Rev. A
SANsurfer Switch Management
2-91
If the devices attached to the non-communicating switch are to be removed from
the fabric, it is necessary to select each of the devices (when the name of an
inactive device is selected, it will change color to a dark red and the word ‘delete’
will appear after the name) and press the Apply button. The device name will then
be removed from the left column of the zoning window.
Adding a Zone (Port Group Zoning Method)
For information about Port Groups Zoning Method, refer to
page 2-27
.
Refer to
Figure 2-31
on
page 2-88
.
1.
Choose a Zone Type. Zone Types are:
•
Hard Zones
•
Broadcast Zones
•
NameServer Zones
•
Segmented Loop
2.
Choose a Zone Index number. The application starts with one zone of each
type. The zone does not include any ports or devices in the zone. A zone of
the selected Zone Type is added by pressing the Add Zone button. To view
existing Zones of the type selected, press the Left or Right Arrow buttons in
the Tool Bar.
3.
(Note: If configuring a Hard Zone, proceed to the next step.) Choose a Hard
Zone View. The Hard Zone View will determine which ports (or devices) are
visible in the left column of the zoning window. If hard zones are defined,
select the hard zone that the desired ports (devices) reside in. If no hard zones
are defined, select the Orphan value.
4.
In the left column, select/deselect ports for the zone:
a.
To select the desired port(s) to add, click either on, or to the left of, the
port type icon. To select more than one port, hold the Ctrl key and left
click the additional ports. When a port is selected, the port number will
change to yellow and the word “add” is placed behind the port number.
b.
To deselect any/all of the ports, click to the right of the port number to
be deselected. Hold the Ctrl key to only deselect the current choice. If
the Ctrl key is not held, clicking to the right of any port will deselect all
selected ports.
NOTE:
The zoning method can only be selected from the Topology window.
Summary of Contents for SANbox-16
Page 1: ...P r e l i m i n a r y SANbox 8 16 SwitchManagement User sManual Publication No 59010 06 Rev A...
Page 16: ...SANbox 8 16 Switch Management List of Tables 59010 06 Rev A User s Manual Notes...
Page 148: ...show command type SANbox 8 16 Switch Management Telnet 59010 06 Rev A User s Manual Notes...
Page 160: ...Configuring SNMP SANbox 8 16 Switch Management SNMP 59010 06 Rev A User s Manual Notes...
Page 180: ...SANbox 8 16 Switch Management Index 59010 06 Rev A User s Manual Notes...