P
reli
mi
na
ry
show <command type>
SANbox-8/16 Switch Management
3-10
Telnet
59010-06 Rev. A
User’s Manual
board_temp = actual measured temperature
Fan 1 status = operation of fan 1
Fan 2 status = operation of fan 2
Port Information = port type definition and fibre channel address
chassis_mode
The command returns a display similar to the following:
Active Admin Chassis Mode:
:NOT USED
config
The command returns a display similar to the following:
SANbox 8
Chassis Num Locked
:YES
Stage Type
:I/O Transfer
Fabric ID
:01
Admin Mode
:online
MFS_TOV
:0
R_T_TOV
:100
E_D_TOV
:2560
R_A_TOV
:5000
Switch Resets
:5000
Port
Admin State
AL Enabled
MFS_MODE
1
Online
True
Normal
2
Online
False
Normal
3
Online
True
Normal
4
Online
True
Normal
5
Online
True
Normal
6
Online
True
Normal
7
Online
True
Normal
8
Online
True
Normal
Where:
Chassis Num Locked:
YES = chassis number assigned manually
NO = chassis number assigned by fabric
Stage Type: I/O Transfer, Cross-Connect, or Hub Emulation
Fabric ID: fabric this switch is attached to
Admin Mode: online, offline, or self-test
MFS_TOV: MFS_Timeout value (in ms)
R_T_TOV: Receiver_Transmitter_Timeout value (in ms)
E_D_TOV: Error_Detect_Timeout value (in ms)
R_A_TOV: Resource_Allocation_Timeout value (in ms)
Switch Resets: number of switch resets since the switch was built
Ports: Admin State: Online, Offline,
AL Enabled: True, False
MFS_MODE: Normal,
Summary of Contents for SANbox-16
Page 1: ...P r e l i m i n a r y SANbox 8 16 SwitchManagement User sManual Publication No 59010 06 Rev A...
Page 16: ...SANbox 8 16 Switch Management List of Tables 59010 06 Rev A User s Manual Notes...