P
reli
mi
na
ry
SANbox-8/16 Switch Management
B-4
Counter Descriptions
59010-06 Rev. A
User’s Manual
Smoothing
Overflow Errors
N/A
Number of times that a violation of FC rules on the incoming
signal were detected. An example of a violation would be an
insufficient number of idles were received between frames.
Sync Loss
N/A
Number of synchronization losses. Loss of sy\nchronization
is detected through reception of invalid transmission words
on the port.
Sync losses 100
ms
fcFPortSyncLosses
Number of synchronization losses (>100 ms) detected by
this port. A loss of synchronization is detected by receipt of
an invalid transmission word.
Table B-1 Counter Names and Descriptions (port display window and telnet) (Continued)
Counter Name
(in port display)
Counter Name
(in telnet)
Description
(Sheet 4 of 4)