Switch Faceplate Display (Port Display/Loop Devices) (Default)
SANbox-8/16 Switch Management
User’s Manual
59010-06 Rev. A
SANsurfer Switch Management
2-53
checked and no error is encountered, the test will terminate when the entered
values have been reached.
Test Length (sec)
The value is a number in the range of 0 to 2
64
/1000 seconds. Entering a value that
exceeds the allowable range, causes the minimum or maximum allowable value to
be entered.
Frame Size
The frame size is a numeric value in the range of 36 to 2148. Entering a value that
exceeds the allowable range, causes the minimum or maximum allowable value to
be entered.
Data Pattern
The data pattern is the test value to be used for testing the port. The value is an
eight byte hexidecimal value, in the range of 00000000 to FFFFFFFF. Enter the
eight byte value in hexidecimal. Entering a value that exceeds the allowable range,
causes the minimum or maximum allowable value to be entered.
Loop Controls
Press Refresh to observe changes made to any of the control commands. The Loop
Controls are described in
Table 2-2
.
Loop Devices
The Loop Devices portion of the window has an entry for each device on the loop.
Each entry is described in
Table 2-3
. Press Refresh to update this portion of the
window.
Summary of Contents for SANbox-16
Page 1: ...P r e l i m i n a r y SANbox 8 16 SwitchManagement User sManual Publication No 59010 06 Rev A...
Page 16: ...SANbox 8 16 Switch Management List of Tables 59010 06 Rev A User s Manual Notes...
Page 148: ...show command type SANbox 8 16 Switch Management Telnet 59010 06 Rev A User s Manual Notes...
Page 160: ...Configuring SNMP SANbox 8 16 Switch Management SNMP 59010 06 Rev A User s Manual Notes...
Page 180: ...SANbox 8 16 Switch Management Index 59010 06 Rev A User s Manual Notes...