4 – Managing Switches
Configuring a Switch
4-22
59056-03 C
A
4.7.2.4
Fabric Device Management Interface
Fabric Device Management Interface (FDMI) provides a means to gather and
display device information from the fabric, and allows FDMI capable devices to
register certain information with the fabric, if FDMI is enabled. SANsurfer Switch
Manager will report any and all FDMI information reported by the entry switch, if
FDMI is enabled on the entry switch. To view FDMI data, FDMI must be enabled
on the entry switch and on all other switches in the fabric which are to report FDMI
data.
FDMI is comprised of the fabric-to-device interface and the application-to-fabric
interface. The fabric-to-device interface enables a device’s management
information to be registered. The application-to-fabric interface provides the
framework by which an application obtains device information from the fabric. Use
the
FDMI HBA Entry Limit
field on the Switch Properties dialog to configure the
maximum number of HBAs that can be registered with a switch. If the number of
HBAs exceeds the maximum number, the FDMI information for those HBAs can
not be registered.
Use the
FDMI Enabled
radio button on the Switch Properties dialog to enable or
disable FDMI. If FDMI is enabled on an HBA, the HBA forwards information about
itself to the switch when the HBA logs into the switch. If FDMI is enabled on a
switch, the switch stores the HBA information in its FDMI database. Disabling
FDMI on a switch clears the FDMI database. If you disable FDMI on a switch, then
re-enable it, you must reset the ports to cause the HBAs to log in again, and thus
forward HBA information to the switch.
To view detailed FDMI information for a device, open the topology display, click
the
Devices
tab, and click the
Information (i)
button in the Details column of the
Devices data window. The Detailed Devices Display dialog displays the specific
information for that device. Refer to
”Devices Data Window” on page 3-33
for
more information.
Summary of Contents for SANbox 5200 Series
Page 48: ...2 Using SANsurfer Switch Manager Using the Faceplate Display 2 30 59056 03 C A Notes...
Page 152: ...4 Managing Switches Displaying Hardware Status 4 46 59056 03 C A Notes...
Page 180: ...5 Managing Ports Graphing Port Performance 5 28 59056 03 C A...
Page 318: ...A Command Line Interface Zoning Command A 138 59056 03 C A Notes...