![background image](http://html2.mh-extra.com/html/qlogic/sanbox-5200-series/sanbox-5200-series_user-manual_3279626242.webp)
A – Command Line Interface
Set Config Command
A-62
59056-03 C
A
PortType
Port type:
1-Gbps/2-Gbps Ports: GL, G, F, FL, Donor. The default
is GL.
10-Gbps Ports: G
SymbolicPortName
Descriptive name for the port. The name can be up to 32
characters excluding #, semicolon (;), and comma (,). The
default is Port n where n is the port number.
ALFairness
(1-Gbps/2-Gbps
ports only)
Arbitration loop fairness. Enables (True) or disables
(False) the switch’s priority to arbitrate on the loop. The
default is False.
DeviceScanEnabled
Enables (True) or disables (False) the scanning of the
connected device for FC-4 descriptor information during
login. The default is True.
ForceOfflineRSCN
Enables (False) or disables (True) the immediate
transmission of RSCN messages when communication
between a port and a device is interrupted. If enabled, the
RSCN message is delayed for 200 ms for locally attached
devices and 400 ms for devices connected through other
switches. The default is False. This parameter is ignored if
IOStreamGuard is enabled.
ARB_FF
(1-Gbps/2-Gbps
ports only)
Send ARB_FF (True) instead of IDLEs (False) on the loop.
The default is False.
InteropCredit
Interoperability credit. The number of buffer-to-buffer
credits per port. 0 means the default (16) is unchanged.
Changing interoperability credits is necessary only for
E_Ports that are connected to non-FC-SW-2-compliant
switches. Contact your authorized maintenance provider
for assistance in using this feature.
ExtCredit
(1-Gbps/2-Gbps
ports only)
Extended credits. The number of port buffer credits that
this port can acquire from donor ports. The default is 0.
FANEnable
(1-Gbps/2-Gbps
ports only)
Fabric address notification. Enables (True) or disables
(False) the communication of the FL_Port address, port
name, and node name to the logged-in NL_Port. The
default is True.
Table A-18. Set Config Port Parameters (Continued)
Parameter
Description
Summary of Contents for SANbox 5200 Series
Page 48: ...2 Using SANsurfer Switch Manager Using the Faceplate Display 2 30 59056 03 C A Notes...
Page 152: ...4 Managing Switches Displaying Hardware Status 4 46 59056 03 C A Notes...
Page 180: ...5 Managing Ports Graphing Port Performance 5 28 59056 03 C A...
Page 318: ...A Command Line Interface Zoning Command A 138 59056 03 C A Notes...