![background image](http://html2.mh-extra.com/html/qlogic/sanbox-5200-series/sanbox-5200-series_user-manual_3279626062.webp)
3 – Managing Fabrics
Securing a Fabric
3-14
59056-03 C
A
The conventions for Port security group members are listed below:
You can enter member world-wide name (WWN), which must be 16 hex
characters, or 23 characters with valid WWN format xx:xx:xx:xx:xx:xx:xx:xx.
The authentication choices are None and Chap.
The Secret field is disabled if authentication is set to None. If authentication
is Chap, the Secret field is enabled.
The
Generate
button is only enabled when authentication is set to Chap.
The conventions for MS security group members are listed below:
You can enter member world-wide name (WWN), which must be 16 hex
characters, or 23 characters with valid WWN format xx:xx:xx:xx:xx:xx:xx:xx.
The CT (common transport) authentication choices are None, MD5, and
SHA-1.
The Secret field is disabled if authentication is set to None, otherwise the
Secret field enabled.
The
Generate
button is only enabled when authentication is Chap.
Secret is 16 byte length for MD5 authentication, and 20 bytes if
authentication is SHA-1.