background image

1 – Introduction

Safety Notices

59096-02 C

1-3

A

1.3

Safety Notices

Warning

 notice indicates the presence of a hazard that has the potential of 

causing personal injury.

4-3

4-20

6-1

Caution

 notice indicates the presence of a hazard that has the potential of 

causing damage to the equipment.

4-4

5-15

6-2

1.4

Sicherheitshinweise

Ein 

Warnhinweis

 weist auf das Vorhandensein einer Gefahr hin, die 

möglicherweise Verletzungen zur Folge hat.

4-3

4-21

6-1

Ein 

Vorsichtshinweis

 weist auf das Vorhandensein einer Gefahr hin, die 

möglicherweise Geräteschäden zur Folge hat.

4-4

5-15

6-2

1.5

Notes informatives relatives à la sécurité

Une note informative 

Avertissement 

indique la présence d’un risque pouvant 

entraîner des blessures.

4-3

4-20

6-1

Une note informative 

Attention

 indique la présence d’un risque pouvant entraîner 

des dégâts matériels.

4-4

5-15

6-2

1.6

Communications Statements

The following statements apply to this product. The statements for other products 
intended for use with this product appear in their accompanying manuals.

Summary of Contents for SANbox 5600 Series

Page 1: ...S i m p l i f y R 59096 02 C Page i SANbox 5600 Series Fibre Channel Switch Installation Guide Firmware Version 5 0...

Page 2: ...ending QLogic SANbox SANblade SANsurfer SANsurfer Switch Manager SANsurfer Management Suite and Multistage are trademarks or registered trademarks of QLogic Corporation General Devices is trademark of...

Page 3: ...tement 1 5 1 6 5 VCCI Class A Statement 1 6 1 7 Laser Safety Information 1 6 1 8 Electrostatic Discharge Sensitivity ESDS Precautions 1 6 1 9 Accessible Parts 1 7 1 10 Pi ces Accessibles 1 7 1 11 Zug...

Page 4: ...ch Manager Web Applet 2 11 2 6 3 Command Line Interface 2 12 2 6 4 SANsurfer Switch Manager Application Programming Interface 2 12 2 6 5 Simple Network Management Protocol 2 12 2 6 6 File Transfer Pro...

Page 5: ...ation to the Switch 4 8 4 2 4 Configure the Workstation 4 9 4 2 4 1 Setting the Workstation IP Address for Ethernet Connections 4 9 4 2 4 2 Configuring the Workstation Serial Port 4 10 4 2 5 Install t...

Page 6: ...Reset User Accounts to Default 5 14 5 4 5 Maintenance Copy Log Files 5 14 5 4 6 Maintenance Remove Switch Config 5 14 5 4 7 Maintenance Remake Filesystem 5 15 5 4 8 Maintenance Reset Switch 5 15 5 4 9...

Page 7: ...d B 35 History Command B 36 Hotreset Command B 37 Image Command B 38 Lip Command B 41 Passwd Command B 42 Ping Command B 43 Ps Command B 44 Quit Command B 45 Reset Command B 46 Security Command B 54 S...

Page 8: ...Four Switch Stack 3 9 3 4 Cascade with a Loop Topology 3 10 3 5 Mesh Topology 3 11 3 6 Multistage Topology 3 12 3 7 Security Example Switches and HBAs 3 17 3 8 Security Example RADIUS Server 3 20 3 9...

Page 9: ...B 48 B 10 Port Configuration Defaults B 49 B 11 Port Threshold Alarm Configuration Defaults B 50 B 12 Zoning Configuration Defaults B 51 B 13 SNMP Configuration Defaults B 51 B 14 RADIUS Configuration...

Page 10: ...Page x 59096 02 C SANbox 5600 Series Fibre Channel Switch Installation Guide S...

Page 11: ...ction 3 describes the factors to consider when planning a fabric Section 4 explains how to install and configure the switch Section 5 describes the diagnostic methods and troubleshooting procedures Se...

Page 12: ...y Guide v3 0 This PDF document can be downloaded at http www qlogic com interopguide info asp inter Fibre Channel Arbitrated Loop FC AL 2 Rev 6 8 Fibre Channel 10 bit Interface Rev 2 3 Definitions of...

Page 13: ...zungen zur Folge hat 4 3 4 21 6 1 Ein Vorsichtshinweis weist auf das Vorhandensein einer Gefahr hin die m glicherweise Ger tesch den zur Folge hat 4 4 5 15 6 2 1 5 Notes informatives relatives la s cu...

Page 14: ...This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference and This device must accept any interference rece...

Page 15: ...compatibility Generic immunity standard Part 1 Residential commercial and light industry IEC1000 4 2 1995 Electrostatic Discharge Immunity Test IEC1000 4 3 1995 Radiated Radio Frequency Electromagneti...

Page 16: ...partment of Health and Human Services DHHS does not consider Class 1 lasers to be hazardous The International Electrotechnical Commission IEC 825 Laser Safety Standard requires labeling in English Ger...

Page 17: ...FRU du commutateur SANbox 5600 Series Fibre Channel Switch sont les suivantes Alimentations de courant 5602 Interfaces aux media d interconnexion appel s SFP transceivers Interfaces aux media d inter...

Page 18: ...our freedom to share and change it By contrast the GNU General Public License is intended to guarantee your freedom to share and change free software to make sure the software is free for all its user...

Page 19: ...on follow 1 12 2 Terms And Conditions For Copying Distribution And Modification 1 This License applies to any program or other work which contains a notice placed by the copyright holder saying it may...

Page 20: ...rmally print such an announcement your work based on the Program is not required to print an announcement These requirements apply to the modified work as a whole If identifiable sections of that work...

Page 21: ...er source or binary form with the major components compiler kernel and so on of the operating system on which the executable runs unless that component itself accompanies the executable If distributio...

Page 22: ...he balance of the section is intended to apply and the section as a whole is intended to apply in other circumstances It is not the purpose of this section to induce you to infringe any patents or oth...

Page 23: ...HE PROGRAM IS LICENSED FREE OF CHARGE THERE IS NO WARRANTY FOR THE PROGRAM TO THE EXTENT PERMITTED BY APPLICABLE LAW EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND OR OTHER PARTIES...

Page 24: ...r version This program is distributed in the hope that it will be useful but WITHOUT ANY WARRANTY without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE See the GNU G...

Page 25: ...nterest in the program Gnomovision which makes passes at compilers written by James Hacker signature of Ty Coon 1 April 1989 Ty Coon President of Vice This General Public License does not permit incor...

Page 26: ...r warranty is available during local standard working hours excluding QLogic Observed Holidays 1 13 2 Training QLogic offers certification training for the technical professional for both the SANblade...

Page 27: ...hone 1 952 932 4040 Fax 1 952 932 4018 Europe Middle East and Africa Region Email emeasupport qlogic com Phone Numbers by Language 353 1 6924960 English 353 1 6924961 Fran ais 353 1 6924962 Deutsch 35...

Page 28: ...1 Introduction Technical Support 1 18 59096 02 C S Notes...

Page 29: ...surfer Switch Manager switch management application version 5 0 and the Command Line Interface CLI Refer to the SANbox 5600 Series Switch Management User s Guide for information about using the SANsur...

Page 30: ...ed switch The chassis LEDs provide information about the switch s operational status These LEDS include the Input Power LED Heartbeat LED and the System Fault LED To apply power to the switch plug the...

Page 31: ...s LEDs will illuminate except the System Fault LED 2 After approximately 1 minute the power on self test POST begins extinguishing the Heartbeat LED 3 When the POST is complete the Input Power LED is...

Page 32: ...ndicate that the switch logic circuitry is receiving the proper DC voltages When the switch is in maintenance mode this LED is extinguished 2 1 2 2 Heartbeat LED Green The Heartbeat LED indicates the...

Page 33: ...ggable SFP transceiver and is capable of 1 Gbps 2 Gbps or 4 Gbps transmission SFPs are hot pluggable User ports can self discover both the port type and transmission speed when connected to public dev...

Page 34: ...alization status of the connected devices After successful completion of the POST the switch extinguishes all Logged In LEDs Following a successful loop initialization or port login the switch illumin...

Page 35: ...r install a transceiver while the switch is operating without harming the switch or the transceiver However communication with the connected device will be interrupted Refer to Install Transceivers on...

Page 36: ...rnet port on a model 5600 the model 5602 is similar A management workstation can be a Windows Solaris or a Linux workstation that is used to configure and manage the switch fabric You can manage the s...

Page 37: ...ctor requires a null modem F F DB9 cable The pins on the switch RS 232 connector are shown in Figure 2 7 and identified in Table 2 1 Refer to Connect the Workstation to the Switch on page 4 8 for info...

Page 38: ...that the power supply is receiving AC voltage and producing the proper DC voltages The Power Supply Fault LED amber illuminates to indicate that a power supply fault exists and requires attention Fig...

Page 39: ...through the Ethernet port of one or more switches and can provide in band management for all other switches in the fabric Refer to the SANbox 5600 Series Switch Management User s Guide for information...

Page 40: ...utor or authorized reseller for information about the SANsurfer Switch Manager API 2 6 5 Simple Network Management Protocol SNMP provides monitoring and trap functions for the fabric SANbox firmware s...

Page 41: ...s of switches are needed The switch uses SFP transceivers in the 1 2 4 Gbps ports but the device host bus adapters you are using may not Consider whether the device adapters use SFP or Gigabit Interfa...

Page 42: ...e defined for a fabric but only one zone set can be active at one time The active zone set determines the current fabric zoning A zoning database is maintained on each switch consisting of all inactiv...

Page 43: ...nd F_Ports 3 2 2 Access Control List Hard Zones Access Control List ACL zoning divides the fabric for purposes of controlling discovery and inbound traffic ACL zoning is a type of hard zoning that is...

Page 44: ...16 credit capacity that is 16 maximum sized frames For fibre optic cables this enables full bandwidth over the following approximate distances 26 kilometers at 1 Gbps 0 6 credits Km 13 kilometers at 2...

Page 45: ...Gbps destination port Similarly one source port can feed multiple destination ports if the combined destination bandwidth is greater than or equal to the source bandwidth In multiple chassis fabrics e...

Page 46: ...ANbox 5600 Series switches divide the 10 Gbps port buffer to balance traffic across the connection The 10 Gbps ports operate with any standard XPAK interface If the 10 Gbps ports are not licensed you...

Page 47: ...User s Guide for information about changing the domain ID and domain ID lock using SANsurfer Switch Manager Refer to the Set Config Command on page B 64 for information about changing the default doma...

Page 48: ...t performance and redundancy Each 10 Gbps port contributes 1 GB of bandwidth between chassis with one chassis hop between any two ports Figure 3 1 shows a two switch stack of model 5600 switches using...

Page 49: ...s Fabrics 59096 02 C 3 9 A Figure 3 3 shows a four switch stack of model 5600 switches using three 3 inch and three 9 inch XPAK switch stacking cables 64 1 2 4 Gbps ports are available for devices Fig...

Page 50: ...op reduces latency because any switch can route traffic in the shortest direction to any switch in the loop The loop also provides failover should a switch fail Using 16 port model 5600 switches the c...

Page 51: ...5600 switches the mesh fabric shown in Figure 3 5 has the following characteristics Each link contributes up to 212 MB of bandwidth between switches 425 MB in full duplex Because of multiple parallel...

Page 52: ...e fabric shown in Figure 3 6 has the following characteristics Each link contributes up to 212 MB of bandwidth between chassis Competition for this bandwidth is less than that of a cascade topology bu...

Page 53: ...her than a direct Ethernet or serial connection The default is enabled Secure Socket Layer SSL Provides for secure SSL connections for SANsurfer Switch Manager the SANsurfer Switch Manager web applet...

Page 54: ...t states the requirements A threat analysis is needed to define the plan of action followed by an implementation that meets the security policy requirements Internet portals such as remote access and...

Page 55: ...te and time to the switch certificate creation date and time For this reason it is important to synchronize the workstation and switch with the same date time and time zone The switch certificate is v...

Page 56: ...tch device or host Authentication can be performed locally using the switch s security database or remotely using a Remote Dial In User Service RADIUS server such as Microsoft RADIUS With a RADIUS ser...

Page 57: ...witch_1 a Create a port group Group_Port_1 in Security_Set_1 with Switch_1 and HBA_1 as members The JBOD is a loop device and is therefore excluded from the port group Port Group on Switch_1 Group_Por...

Page 58: ...1 secret must be shared with the Switch_2 security database 2 Configure security on HBA_1 using the appropriate management tool Logins between the Switch_1 and HBA_1 will be challenged for their respe...

Page 59: ...2 as members This is a replication of the entries in ISL group in the Switch_1 security database 5 Save Security_Set_2 on Switch_2 and activate it Port Group on Switch_2 Group_Port_2 HBA_2 Node WWN 10...

Page 60: ...s passed from the switch to Radius_1 in the following cases HBA_1 login to Switch_1 Switch_1 login to Switch_2 Switch_2 login to Switch_1 Figure 3 8 Security Example RADIUS Server Device Switch_1 WWN...

Page 61: ...and is therefore excluded from the port group Radius_1 Configuration on Switch_1 and Switch_2 Device Authentication Order RadiusLocal Authenticate devices using the RADIUS server security database fi...

Page 62: ...ecret must be shared with the Switch_2 security database 3 Configure security on HBA_1 using the appropriate management tool Logins between the Switch_1 and HBA_1 will be challenged CHAP for their res...

Page 63: ...ity Example Host Authentication Consider the fabric shown in Figure 3 9 In this fabric only Switch_2 and HBA_2 APP_2 support security where APP_2 is a host application The objective is to secure the m...

Page 64: ...The type of switch worldwide name you use in the switch security database must be the same as that in the HBA security database For example if you specify a switch with a port worldwide name in the sw...

Page 65: ...configured on HBA_2 or APP_2 4 Save Security_Set_2 and prepare to activate it Activating a security set does not affect currently logged in ports Therefore to apply the security policy that you design...

Page 66: ...using the switch s user account database or it can be done remotely using a RADIUS server such as Microsoft RADIUS Authenticating user logins on a RADIUS server requires a secure management connection...

Page 67: ...resident on the switch Consider how many fabrics will be managed how many management workstations are needed and whether the fabrics will be managed with the CLI SANsurfer Switch Manager or the SANsu...

Page 68: ...3 Planning Fabric Management 3 28 59096 02 C S Notes...

Page 69: ...ning SANsurfer Switch Manager are described in Table 4 1 Telnet workstations require an RJ 45 Ethernet port or an RS 232 serial port and an operating system with a Telnet client Table 4 1 Management W...

Page 70: ...witch and accessories The SANbox 5600 Series product is shipped with the components shown in Figure 4 1 SANbox 5600 Series Fibre Channel Switch 1 with firmware installed Power cord 1 model 5600 Power...

Page 71: ...model 5600 switch can be rack mounted without rails however rail kits are available from General Devices Company model number C 874 General Devices Company LTD P O Box 39100 Indianapolis IN 46239 010...

Page 72: ...ict chassis air flow Allow 16 cm 6 5 in minimum clearance at the front and rear of the switch surface mount or rack for service access and ventilation Multiple rack mounted units connected to the AC s...

Page 73: ...own in Figure 4 2 Choose the bracket screw holes to produce the setback you want Place the switch in the rack and fasten the bracket flanges to the rack with two screws on each side Figure 4 2 Mountin...

Page 74: ...iety of SFP and XPAK transceivers To install a transceiver insert the transceiver into the port and gently press until it snaps in place To remove a transceiver gently press the transceiver into the p...

Page 75: ...line of the respective switch faceplates as shown in Figure 4 5 When installing the 3 inch XPAK switch stacking cable insert the cable connectors into the 10 Gbps ports at the same time Figure 4 5 In...

Page 76: ...e switch RJ 45 Ethernet connector through an Ethernet switch or a hub This requires a 10 100 Base T straight cable as shown in Figure 4 6 Direct Ethernet connection from the management workstation to...

Page 77: ...rkstation IP Address for Ethernet Connections The default IP address of a new switch is 10 0 0 1 To ensure that your workstation is configured to communicate with the 10 0 0 subnet refer to the follow...

Page 78: ...and choose the OK button Bits per second 9600 Data Bits 8 Parity None Stop Bits 1 Flow Control None For Linux a Set up minicom to use the serial port Create or modify the etc minirc dfl file with the...

Page 79: ...Series Switch Management User s Guide for more information about using exiting and uninstalling SANsurfer Management Suite and SANsurfer Switch Manager 4 2 5 1 SANsurfer Switch Manager You can instal...

Page 80: ...ion instructions Linux_5 00 xx xx bin For a Solaris platform 1 Open a terminal window If the disk isn t already mounted enter the following command volcheck 2 Enter following command to move to the di...

Page 81: ...click the drive letter which contains the SANsurfer Management Suite Disk b Locate and double click the Start_Here htm file to open the SANsurfer Management Suite start page in your default browser 2...

Page 82: ...step 9 Otherwise no upgrade is needed and the SMS installation is complete 9 To start the installer open the zip file and run the SANsurferSwitchMgr_Windows_5 00 xx exe file 10 When prompted for an in...

Page 83: ...wser to view the Start_Here htm document using one of the following commands mozilla file mnt cdrom Start_Here htm or netscape file mnt cdrom Start_Here htm d The SANsurfer Management Suite start page...

Page 84: ...5 00 xx is greater than what is currently installed on your workstation down load the new version and proceed to step 11 Otherwise no upgrade is needed and the SMS installation is complete 11 From the...

Page 85: ...ment Suite start page click the SANbox Switch Software button 3 On the SANbox Switch Software page scroll to the SANbox Series area 4 In the Operating System column click the Solaris SPARC link 5 Clic...

Page 86: ..._5 00 xx 13 Change directories to the package location cd usr opt QLGCsol bin 14 Locate and execute the file sbm_over_sms sh sbm_over_sms sh 15 When prompted for the SMS installation directory enter d...

Page 87: ...button When you power up the switch the Configuration Wizard will recognize the switch and lead you through the configuration process To start SANsurfer Switch Manager from SANsurfer Management Suite...

Page 88: ...e must be rated at 10 Amps and be approved by UL and CSA For 250 Volt electrical service The cable must be rated at 10 Amps meet the requirements of H05VV F and be approved by VDE SEMKO and DEMKO AVER...

Page 89: ...Metallteilen des switch Geh uses verursachen Der Kunde tr gt die Verantwortung f r eine vorschriftsm ige Verdrahtung und Erdung der Steckdose zur Vermeidung eines elektrischen Schlages In manchen L nd...

Page 90: ...t license key 2 After a couple seconds the System Fault LED is extinguished while the Input Power LED and Heartbeat LED remain illuminated 3 After approximately one minute the POST executes and the He...

Page 91: ...do the following 1 Open a command window according to the type of workstation and connection Ethernet all platforms Open a Telnet session with the default switch IP address and log in to the switch w...

Page 92: ...Solaris Open a command window and enter the following command tip sanbox2 2 Open an admin session and enter the Set Setup System command Enter the values you want for switch IP address Eth0NetworkAddr...

Page 93: ...anagement workstation as new firmware becomes available You can use the SANsurfer Switch Manager application or the CLI to install new firmware NOTE You can load and activate version 5 0 firmware on a...

Page 94: ...and select the firmware file to be uploaded 3 Click the Start button to begin the firmware load process You will be shown a message warning you that the switch will be reset to activate the firmware 4...

Page 95: ...erminate all management sessions including any Telnet sessions When the firmware activation is complete you may log in to the switch again Do you want to continue y n y Press q and the ENTER key to ab...

Page 96: ...itch is not disruptive and does not require a switch reset To upgrade a switch using SANsurfer Switch Manager do the following 1 Add a fabric with the IP address of the switch you want to upgrade 2 Op...

Page 97: ...D indications Power On Self Test Diagnostics describe the Heartbeat LED and the port Logged In LED indications Power Supply Diagnostics describes Power Supply Status LED and Power Supply Fault LED ind...

Page 98: ...tinue No Make necessary repairs For a model 5600 switch if the condition remains contact your authorized maintenance provider For a model 5602 switch if the condition remains continue 3 Inspect the po...

Page 99: ...f a critical error occurs the Heartbeat LED will show an error blink pattern and the System Fault LED will illuminate If there are non critical errors the switch disables the failed ports and flashes...

Page 100: ...that a POST failure or a system error has left the switch inoperable If a system error occurs contact your authorized maintenance provider Momentarily press and release the Maintenance button to reset...

Page 101: ...Exit 1 Image Unpack 2 Reset Network Config 3 Reset User Accounts to Default 4 Copy Log Files 5 Remove Switch Config 6 Remake Filesystem 7 Reset Switch 8 Update Boot Loader Option 6 5 When the recreate...

Page 102: ...will reset SANbox admin config restore 5 2 1 4 Over Temperature Blink Pattern An over temperature blink pattern is 5 blinks followed by a two second pause The 5 blink error pattern indicates that the...

Page 103: ...mand then power down the switch Contact your authorized maintenance provider 5 2 2 Logged In LED Indications Port diagnostics are indicated by the Logged In LED for each port as shown in Figure 5 2 Fi...

Page 104: ...n isolated E_Port 1 Does the event browser show an alarm about an invalid attach on the affected port Yes Review the ISL group in the active security set to ensure that the membership includes the nec...

Page 105: ...ne membership between the two active zone sets Are they the same Yes Contact your authorized maintenance provider No Deactivate one of the active zone sets or edit the conflicting zones so that their...

Page 106: ...fer Switch Manager application Refer to the Show Config Command on page B 107 Refer to Table B 11 for a list of the alarm configuration defaults Are the thresholds and sample window correct Yes Contin...

Page 107: ...as failed Replace the power supply with another having the same air flow direction Air flow direction is indicated on the power supply part number label Refer to Power Supply Removal and Replacement o...

Page 108: ...me password to the default Copy the log file Restore factory defaults for all but user accounts and zoning Restore all switch configuration parameters to the factory default values Reset the switch Up...

Page 109: ...l operation momentarily press and release the Maintenance button or power cycle the switch 5 4 2 Maintenance Image Unpack This option unpacks and installs new firmware when the current firmware has be...

Page 110: ...configuration values 5 4 4 Maintenance Reset User Accounts to Default This option restores the password for the Admin account name to the default password and removes all other user accounts from the...

Page 111: ...elnet session exits maintenance mode and reboots the switch using the current switch configuration All unpacked firmware image files that reside on the switch are deleted 5 4 9 Maintenance Update Boot...

Page 112: ...5 Diagnostics Troubleshooting Recovering a Switch 5 16 59096 02 C S Notes...

Page 113: ...Replace only with the same or equivalent type recommended by the manufacturer Dispose of the used battery according to the manufacturer s instructions WARNUNG Bei unsachgem ausgetauschter Batterie be...

Page 114: ...left and right power supplies are the same unit When removing or replacing a power supply consider the following The left and right power supplies are interchangeable However you must orient the powe...

Page 115: ...power supply is compatible with the switch air flow direction The part number label on the power supply indicates the air flow direction as shown in Figure 6 2 3 With the AC receptacle on the right s...

Page 116: ...6 Removal Replacement Power Supply Removal and Replacement 6 4 59096 02 C S Notes...

Page 117: ...Protocols FC PH Rev 4 3 FC PH 2 FC PH 3 FC AL Rev 4 6 FC AL 2 Rev 7 0 FC FLA FC GS FC GS 2 FC GS 3 FC FG FC Tape FC VI FC SW 2 Fibre Channel Element MIB RFC 2837 Fibre Alliance MIB Version 4 0 Fibre C...

Page 118: ...edits per port ASIC embedded memory Media Type Ports 0 15 Ports 16 19 SFP optical transceiver XPAK switch stacking cables Fabric Port Speed Ports 0 15 Ports 16 19 1 0625 2 125 or 4 250 Gbps 12 750 Gbp...

Page 119: ...supplies model 5602 only Management Methods SANsurfer Switch Manager Graphical User Interface Application Programming Interface Command Line Interface GS 3 Management Server SNMP FTP Maintenance Conn...

Page 120: ...1 70 43 2 mm 1U 19 69 500 mm Weight 9 lbs 4 08 Kg 16 lbs 7 25 Kg Operating voltage 100 to 240 VAC 50 to 60 Hz Power source loading maximum 1 A at 120 VAC 0 5 A at 240 VAC Heat Output maximum 100 watt...

Page 121: ...48m 0 to 10 000 feet 0 to 15 240m 0 to 50 000 feet Vibration Operating Non operating IEC 68 2 5 500 Hz random 0 21 G rms 10 minutes 5 500 Hz random 2 09 G rms 10 minutes Shock Operating Non operating...

Page 122: ...nada EN60950 2000 EC CB Scheme IEC 60950 1999 Emissions Standards FCC Part 15B Class A ICES 03 Issue 3 VCCI Class A ITE CISPR 22 Class A EN 55022 Class A Voltage Fluctuations EN 61000 3 3 Harmonics EN...

Page 123: ...nfigurations Commands B 1 Logging On to a Switch To log on to a switch using Telnet open a command line window on the workstation and enter the Telnet command followed by the switch IP address telnet...

Page 124: ...Refer to Passwd Command on page B 42 for information about changing passwords B 3 Working with Switch Configurations Successful management of switches and fabrics with the command line interface depe...

Page 125: ...also open a Config Edit session with the Config Edit command and indicate which configuration you want to modify If you do not specify a configuration name the active configuration is assumed The Con...

Page 126: ...d switch configurations including the default configuration This includes port switch port threshold alarm and zoning configuration components All SNMP and network information defined with the Set Set...

Page 127: ...ftp put config_switch_169_10112003 configdata Local file config_switch_169_10112003 Remote file configdata ftp quit The restore process replaces all configuration information on the switch and afterwa...

Page 128: ...nitoring and configuration tasks Commands related to monitoring tasks are available to all account names Commands related to configuration tasks are available only within an admin session An account m...

Page 129: ...ommands Alias1 CIM1 CIMListener CIMSubscription Config1 Create Date1 Feature1 Firmware Install Group1 Hardreset Hotreset Image Lip Passwd Reset Security Securityset1 Set1 Set Config Set Log Set Port1...

Page 130: ...start or begin Opens the admin session end or stop Closes the admin session The Hardreset Hotreset Logout Shutdown and Reset Switch commands will also end an admin session cancel Terminates an Admin...

Page 131: ...ias can have a maximum of 2000 members A port device in member_list can have any of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs can be 1 239 port numbers can...

Page 132: ...This keyword does not require an admin session remove alias member_list Removes the ports devices given by member_list from the alias given by alias Use a space to delimit ports devices in member_list...

Page 133: ...ts save Keywords cancel Terminates the current CIM edit session without saving changes that were made clear Clears all CIM listener and subscription configurations from the switch edit Opens a CIM edi...

Page 134: ...nd Line Interface CIM Command B 12 59096 02 C S The following is an example of the CIM Limits command SANbox cim limits Cim Attribute Maximum MaxListeners 32 MaxSubscriptions 50 MaxSubscriptionsPerLis...

Page 135: ...ame Use a space to delimit subscription names in subscription_list create listener_name Prompts you in a line by line fashion to create a CIM listener with the name given by listener_name listener_nam...

Page 136: ...r create listener_1 A list of attributes with formatting and current values will follow Enter a new value or simply press the ENTER key to accept the current value If you wish to terminate this proces...

Page 137: ...subscription_name from the CIM database Table B 4 CIM Subscription Configuration Parameters Parameter Description Name Subscription name FilterID Event type for which the switch monitors and sends an...

Page 138: ...follow Enter a new value or simply press the ENTER key to accept the current value If you wish to terminate this process before reaching the end of the list press q or Q and the ENTER key to do so Fil...

Page 139: ...configuration can be active at a time backup Creates a file named configdata which contains the system configuration information To download this file open an FTP session log in with account name pas...

Page 140: ...ame If you omit config_name the value for config_name you chose for the most recent Config Edit command is used config_name can be up to 31 characters excluding semicolon and comma The switch supports...

Page 141: ...igdata from the workstation to the switch and then restore the configuration ftp symbolic_name or ip_address user images password images ftp bin ftp put configdata ftp quit SANbox admin start SANbox a...

Page 142: ...p file dump_support tgz on the switch If your workstation has an FTP server you can proceed with the command prompts to send the file from the switch to a remote host Otherwise you can use FTP to down...

Page 143: ...ocaldomain FTP server Version wu 2 6 1 18 ready 331 Password required for johndoe Password xxxxxxx 230 User johndoe logged in cd bin support 250 CWD command successful lcd itasca conf images Local dir...

Page 144: ...e in binary mode with the Get command SANbox admin create support Log Msg Creating the support file this will take several seconds FTP the dump support file to another machine y n n SANbox admin quit...

Page 145: ...date this requires an admin session If you omit MMDDhhmmCCYY the current date is displayed which does not require an admin session Notes Network Time Protocol NTP must be disabled to set the time wit...

Page 146: ...nsitive log Displays a list of installed license key features Notes SANbox 5600 Series switches can be upgraded to 12 16 or 20 port configurations Examples The following is an example of the Feature A...

Page 147: ...Firmware Install command SANbox admin firmware install Warning Installing new firmware requires a switch reset Continuing with this action will terminate all management sessions including any Telnet s...

Page 148: ...sion and a Security Edit session Refer to the Security Command on page B 54 for information about starting a Security Edit session The List Members Securitysets and Type keywords are available without...

Page 149: ...does not support the Primary Hash the switch will use the Secondary Hash Primary Secret Hexadecimal string that is encrypted by the Primary Hash for authentication with the ISL group member The strin...

Page 150: ...e Pri mary Hash the switch will use the Secondary Hash Primary Secret Hexadecimal string that is encrypted by the Primary Hash for authentication with the Port group member The string has the fol lowi...

Page 151: ...itches Port Configures security for attachments to N_Port devices MS Configures security for attachments to N_Port devices that are issuing management server commands Table B 7 MS Group Member Attribu...

Page 152: ...use to decipher the encrypted Secret sent by the MS group member Hash values are MD5 or SHA 1 Primary Secret ISL and Port Groups Hexadecimal string that is encrypted by the Primary Hash for authentica...

Page 153: ...e group given by group_new securitysets group Displays the list of security sets of which the group given by group is a member This keyword is available without an Admin session type group Displays th...

Page 154: ...ue Binding domain ID 1 239 0 None 0 Finished configuring attributes To discard this configuration use the security cancel command The following is an example of the Group Edit command SANbox admin sec...

Page 155: ...command SANbox group list Group SecuritySet group1 ISL alpha group2 Port alpha The following is an example of the Group Members command SANbox group members group1 Current list of members for Group g...

Page 156: ...tivates the pending firmware and clears the alarm log To save the alarm log before resetting refer to the Set Log Command on page B 76 Authority Admin session Syntax hardreset Notes To reset the switc...

Page 157: ...mand all Displays a list of all available commands including command variations Examples The following is an example of the Help Config command SANbox help config config CONFIG_OPTIONS The config comm...

Page 158: ...hes command_string Enter line number to re execute the corresponding command from the History display Enter partial command string to re execute a command that matches the command string Enter to re e...

Page 159: ...re initialize attached devices under the following conditions The current firmware version is a 4 0 4 1 4 2 or 5 x version that precedes the upgrade version No changes are being made to switches in th...

Page 160: ...ress given by ip_address and an account name given by account_name If an account name needs a password to access the FTP server the system will prompt you for it install Downloads firmware from a remo...

Page 161: ...with the IP address 4 Enter the following account name and password user images password images 5 Activate binary mode and copy the firmware image file on the switch ftp bin ftp put filename 6 Wait fo...

Page 162: ...lling new firmware requires a switch reset Continuing with this action will terminate all management sessions including any Telnet sessions When the firmware activation is complete you may log in to t...

Page 163: ...and Reinitializes the specified loop port Authority Admin session Syntax lip port_number Keywords port_number The number of the port to be reinitialized Ports are numbered beginning with 0 Examples Th...

Page 164: ...name The user account name To change the password for an account name other than your own you must open an admin session with the account name Admin If you omit account_name you will be prompted to ch...

Page 165: ...ess of the switch to query Broadcast IP addresses such as 255 255 255 255 are not valid Examples The following is an example of a successful Ping command SANbox ping 10 20 11 57 Ping command issued Wa...

Page 166: ...18 35 ds 342 327 0 2 00 11 29 3 01 18 35 mgmtApp 343 327 0 0 00 00 04 3 01 18 35 fc2 344 327 0 0 00 02 16 3 01 18 35 nserver 345 327 0 0 00 02 44 3 01 18 35 mserver 346 327 0 8 00 35 12 3 01 18 35 uti...

Page 167: ...B Command Line Interface Quit Command 59096 02 C B 45 A Quit Command Closes the Telnet session Authority None Syntax quit exit or logout Notes You can also enter Control D to close the Telnet session...

Page 168: ...name the active configuration is reset You must activate the configuration for the changes to take effect for switch port and port threshold alarm configuration default values factory Resets switch co...

Page 169: ...his reset disrupts traffic and does the following Activates the pending firmware Closes all management sessions Clears the event log To save the event log before resetting refer to the Set Log Command...

Page 170: ...h configuration values Table B 9 Switch Configuration Defaults Parameter Default Admin State Online Broadcast Enabled True InbandEnabled True FDMIEnabled True FDMIEntries 1000 DefaultDomain ID 1 0x He...

Page 171: ...ine Link Speed Auto 10 Gbps Port Type GL G Symbolic Name Portn where n is the port number 10G n where n is the port number ALFairness False N A DeviceScanEnabled True True ForceOfflineRSCN False False...

Page 172: ...MonitoringEnabled False CRCErrorsMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 25 1 10 DecodeErrorsMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 200 0 10 ISLMonit...

Page 173: ...alse Table B 13 SNMP Configuration Defaults Parameter Default SNMPEnabled True Contact syscontact undefined Location sysLocation undefined Description SANbox 5600 Series FC Switch Trap 1 5 Address Tra...

Page 174: ...ault DeviceAuthOrder Local UserAuthOrder Local TotalServers 1 DeviceAuthServer False UserAuthServer False AccountingServer False ServerIPAddress 10 0 0 1 ServerUDPPort 1812 Timeout 2 seconds Retries 0...

Page 175: ...rameter Default Ethernet Network Discovery Static Ethernet Network IP Address 10 0 0 1 Ethernet Network IP Mask 255 0 0 0 Ethernet Gateway Address 10 0 0 254 Admin Timeout 30 minutes InactivityTimeout...

Page 176: ...ecurity set its groups and group members This keyword does not require an Admin session cancel Closes a Security Edit session without saving changes Use the Edit keyword to open a Security Edit sessio...

Page 177: ...ere made This keyword does not require an Admin session limits Displays the current totals and the security database limits for the number of security sets groups members per group and total members T...

Page 178: ...Binding 0 10 00 00 00 00 10 21 17 Authentication Chap Primary Hash MD5 Primary Secret Secondary Hash SHA 1 Secondary Secret Binding 0 The following is an example of the Security History command SB211...

Page 179: ...ple of the Security List command SANbox admin security security list SB211 192 security list Active Security Information SecuritySet Group GroupMember No active securityset defined Configured Security...

Page 180: ...ity_set group rename security_set_old security_set_new Keywords activate security_set Activates the security set given by security_set This keyword deactivates the active security set Close the Securi...

Page 181: ...bers of the security set given by security_set This keyword is available without an Admin session list Displays a list of all security sets This keyword is available without an Admin session remove se...

Page 182: ...ng is an example of the Securityset Groups command SANbox securityset groups alpha Current list of Groups for SecuritySet alpha group1 ISL group2 Port The following is an example of the Securityset Li...

Page 183: ...or clears the alarm log option can be one of the following clear Clears the alarm log history This value requires an Admin session on Enables the display of alarms in the session output stream off Dis...

Page 184: ...ing Active List off Allows continuous display of information without a break port option Sets port state and speed for the specified port The previous Set Config Port settings are restored after a swi...

Page 185: ...orkstation The default is Universal Time UTC also known as Greenwich Mean Time GMT This keyword prompts you to choose a region then a subregion to specify the time zone Examples The following examples...

Page 186: ...Enter key to accept the current value shown in brackets Enter q to end the configuration for one port or qq to end the configuration for all ports Table B 18 describes the port parameters ports port_n...

Page 187: ...device is interrupted If enabled the RSCN mes sage is delayed for 200 ms for locally attached devices and 400 ms for devices connected through other switches The default is False This parameter is ign...

Page 188: ...arameter appears only if AutoPerfTuning is False Enables True or disables False VI preference routing The default is False Enabling VIEnable will disable MFSEnable MSEnable Management server enable En...

Page 189: ...rameters PDISCPingEnable 1 2 4 Gbps ports only Enables True or disables False the transmission of ping messages from the switch to all devices on a loop port The default is True Table B 19 Security Co...

Page 190: ...illiseconds the switch waits to allow two ports to allocate enough resources to establish a link The default is 10000 E_D_TOV Error Detect Timeout Value The number of millisec onds a port is to wait f...

Page 191: ...shold Parameters Parameter Description Threshold Monitoring Enabled Master enable disable parameter for all events Enables True or disables False the generation of all enabled event alarms The default...

Page 192: ...ent memory Refer to InteropMode on page B 68 The default is True Disabling the Autosave parameter can be useful to prevent the propagation of zoning information when experimenting with dif ferent zoni...

Page 193: ...s A Auto Auto PortType GL G F FL Donor GL SymPortName string max 32 chars Port1 ALFairness True False False DeviceScanEnable True False True ForceOfflineRSCN True False False ARB_FF True False False I...

Page 194: ...ER key to do so Configuring Port Number 16 AdminState 1 Online 2 Offline 3 Diagnostics 4 Down Online LinkSpeed 10 10Gb s 10Gb s PortType G F G SymPortName string max 32 chars 10G 16 DeviceScanEnable T...

Page 195: ...g cancel command The following is an example of the Set Config Switch command SANbox admin start SANbox admin config edit SANbox admin config set config switch A list of attributes with formatting and...

Page 196: ...imal value 1 1000 200 FallingTrigger decimal value 0 1000 0 SampleWindow decimal value 1 1000 sec 10 ISLMonitoringEnabled True False True RisingTrigger decimal value 1 1000 2 FallingTrigger decimal va...

Page 197: ...ue or simply press the ENTER key to accept the current value If you wish to terminate this process before reaching the end of the list press q or Q and the ENTER key to do so InteropAutoSave True Fals...

Page 198: ...l log entries and stores the result in new file named logfile that is maintained in switch memory where it can be downloaded using FTP To download logfile open an FTP session log in with account name...

Page 199: ...automatically display on the screen according to the event severity levels given by filter filter can be one of the following values Critical Critical severity level events The critical level describe...

Page 200: ...ibes events that are generally not disruptive to the administration or operation of the fabric but are more important than the informative level events Info Monitors informative warning and critical e...

Page 201: ...and start Starts the logging of events based on the Port Component and Level keywords assigned to the current configuration The logging continues until you enter the Set Log Stop command stop Stops lo...

Page 202: ...PB to a specific Arbitrated Loop Physical Address ALPA or to all ALPAs on the arbitrated loop alpa can be a specific ALPA or the keyword ALL to choose all ALPAs clear Clears the counters on the port T...

Page 203: ...s for the specified port Online Places the port online This activates and prepares the port to send data Offline Places the port offline This prevents the port from receiving signal and accepting a de...

Page 204: ...e default Radius Authenticate devices using only the security database on the RADIUS server RadiusLocal Authenticate devices using the RADIUS server security database first If the RADIUS server is una...

Page 205: ...en enabled user activity is audited whether UserAuthServer is enabled or not The default is False The accounting server UDP port number is the ServerUDPPort value plus 1 default 1813 Timeout Number of...

Page 206: ...tion your workstation must use an SSH client The default is False GUIMgmtEnabled Enables True or disables False out of band manage ment of the switch with SANsurfer Switch Manager the SANsurfer Switc...

Page 207: ...synchronizing of switch and workstation dates and times with an NTP server This helps to prevent invalid SSL certificates and timestamp confusion in the event log The default is False This parameter i...

Page 208: ...0 Addresses other than 0 0 0 0 for all traps must be unique Trap 1 5 Port Specifies the workstation port to which SNMP traps are sent Valid workstation port numbers are 1 65535 The default is 162 Trap...

Page 209: ...es True or disables False SNMP communication with other switches in the fabric The default is True NOTE Changing the IP address will terminate all Ethernet management sessions Table B 26 System Config...

Page 210: ...tocol NTP client on the switch This client enables the switch to synchronize its time with an NTP server This feature supports NTP version 4 and is compatible with version 3 An Ethernet connection to...

Page 211: ...ver True False True AccountingServer True False False Timeout decimal value 10 30 secs 10 Retries decimal value 1 3 0 None 0 SignPackets True False False Secret 32 hex or 16 ASCII char value Do you wa...

Page 212: ...lowed options above warning Trap1Version 1 2 2 Trap1Enabled True False False Trap2Address dot notated IP Address 0 0 0 0 Trap2Port decimal value 162 Trap2Severity see allowed options above warning Tra...

Page 213: ...d the ENTER key to do so Eth0NetworkDiscovery 1 Static 2 Bootp 3 Dhcp 4 Rarp Static Eth0NetworkAddress dot notated IP Address 10 0 0 1 Eth0NetworkMask dot notated IP Address 255 255 255 0 Eth0GatewayA...

Page 214: ...r_name cimsubscription subscription_name config option domains donor fabric fdmi port_wwn interface log option lsdb mem count ns option pagebreak perf option port port_number post log setup option ste...

Page 215: ...s the broadcast tree information and all ports that are currently transmitting and receiving broadcast frames chassis Displays chassis component status and temperature cimlistener listener_name Displa...

Page 216: ...t Displays information about memory activity for the number of seconds given by count If you omit count the value 1 is used Displayed memory values are in 1K block units ns option Displays name server...

Page 217: ...on failed Bad Frames Number of frames that have framing errors ClassXFramesIn Number of class x frames received by this port ClassXFramesOut Number of class x frames sent by this port ClassXWordsIn Nu...

Page 218: ...ignal causes the switch to attempt to re establish the link If the link is not re established a link failure is counted A link reset is performed after a link failure Login Number of device logins Log...

Page 219: ...rom the screen and used for diagnosing problems This keyword is intended for use at the request of your authorized maintenance provider The commands that are executed include the following Alias List...

Page 220: ...B 28 Switch Operational Parameters Parameter Description SymbolicName Descriptive name for the switch SwitchWWN Switch world wide name SwitchType Switch model BootVersion PROM boot version CreditPool...

Page 221: ...me active at the next reset or power cycle ActiveConfiguration Name of the switch configuration that is in use AdminState Switch administrative state AdminModeActive Admin session status BeaconOnStatu...

Page 222: ...WWN 10 00 00 c0 dd 00 72 45 Domain 100 0x64 WWN 10 00 00 c0 dd 00 ba 68 Domain 101 0x65 WWN 10 00 00 60 df 22 2e 06 Domain 102 0x66 WWN 10 00 00 c0 dd 00 90 ef Domain 103 0x67 WWN 10 00 00 60 69 50 0...

Page 223: ...wareVersion 03 02 13 OperatingSystem SunOS 5 8 MaximumCTPayload 2040 NumberOfPorts 1 Port 21 01 00 e0 8b 27 aa bc SupportedFC4Types FCP SupportedSpeed 2Gb s CurrentSpeed 2Gb s MaximumFrameSize 2048 OS...

Page 224: ...C4Type FCP FC4Desc NULL The following is an example of the Show Interface command SANbox show interface eth0 Link encap Ethernet HWaddr 00 C0 DD 00 BD ED inet addr 10 20 68 107 Bcast 10 20 68 255 Mask...

Page 225: ...mbolicName Port8 MaxCredit 16 SyncStatus SyncAcquired MediaSpeeds 1Gb s 2Gb s 4Gb s XmitterEnabled True ALInit 5 LIP_F8_AL_PS 0 ALInitError 0 LIP_F8_F7 0 BadFrames 0 LinkFailures 2 Class2FramesIn 0 Lo...

Page 226: ...x x x 0 2 day month date time year PendingImageVersion build date Vx x x 0 17 day month date time year ActiveConfiguration default AdminState Online AdminModeActive False BeaconOnStatus False Operatio...

Page 227: ...rtID 650100 PortWWN 20 01 00 c0 dd 00 91 11 PortType F Remote Link Information Device 0 NodeWWN 50 80 02 00 00 06 d5 38 PortType NL Description NULL IPAddress 0 0 0 0 Device 1 NodeWWN 20 00 00 20 37 2...

Page 228: ...SHell CLISH SystemDescription SANbox 5600 Series FC Switch Eth0NetworkAddress 10 20 11 192 use set setup system to update MACAddress 00 c0 dd 00 71 ee WorldWideName 10 00 00 c0 dd 00 71 ed ChassisSeri...

Page 229: ...hold zoning Keywords port port_number Displays configuration parameters for the port number given by port_number Ports are numbered beginning with 0 If port_number is omitted all ports are specified s...

Page 230: ...nabled True AutoPerfTuning False LCFEnabled False MFSEnabled True MSEnabled True NoClose False IOStreamGuard Disabled VIEnabled False PDISCPingEnable True The following is an example of the Show Confi...

Page 231: ...default Switch Configuration Information AdminState Online BroadcastEnabled False InbandEnabled True FDMIEnabled False FDMIEntries 10 DomainID 19 0x13 DomainIDLock True SymbolicName sw108 R_A_TOV 100...

Page 232: ...RisingTrigger 25 FallingTrigger 0 SampleWindow 10 ISLMonitoringEnabled True RisingTrigger 2 FallingTrigger 0 SampleWindow 10 LoginMonitoringEnabled True RisingTrigger 5 FallingTrigger 1 SampleWindow...

Page 233: ...r_of_events component display filter level options port settings Keywords number_of_events Specifies the number of the most recent events to display from the event log number_of_events must be a posit...

Page 234: ...to the component or severity level filter given by filter filter can be one of the following Info Displays all informative events Warning Displays all warning events Critical Displays all critical eve...

Page 235: ...settings Displays the current filter settings for component severity level port and display level This command is equivalent to executing the following commands separately Show Log Component Show Log...

Page 236: ...o 330 day month date time year I Eport Port 0 8 Processing EFP oxid 0x8 331 day month date time year I Eport Port 0 8 Eport State E_A2_IDLE 332 day month date time year I Eport Port 0 8 EFP WWN 0x1000...

Page 237: ...tinuous performance data in bytes second received for the port group 0 15 or 16 19 that includes port_number If you omit port_number ports 0 15 are displayed Type q and press the Enter key to stop the...

Page 238: ...mber ports 0 15 are displayed Type q and press the Enter key to stop the display Examples The following is an example of the Show Perf command SANbox show perf Port Bytes s Bytes s Bytes s Frames s Fr...

Page 239: ...to stop display 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 0 0 0 0 0 0 0 137M 58K 0 0 0 0 8K 137M 0 0 0 0 0 0 0 0 136M 58K 0 0 0 0 8K 136M 0 0 0 0 0 0 0 0 135M 58K 0 0 0 0 7K 135M 0 0 0 0 0 0 0 0 137M 58...

Page 240: ...service status information snmp Displays the current SNMP settings system Displays the current system settings Examples The following is an example of the Show Setup Mfg command SANbox show setup mfg...

Page 241: ...edGUIEnabled True SNMPEnabled True NTPEnabled True CIMEnabled True FTPEnabled True ManagementServerEnabled True The following is an example of the Show Setup RADIUS command SANbox show setup radius Ra...

Page 242: ...ort 162 Trap1Severity warning Trap1Version 2 Trap1Enabled False Trap2Address 0 0 0 0 Trap2Port 162 Trap2Severity warning Trap2Version 2 Trap2Enabled False Trap3Address 0 0 0 0 Trap3Port 162 Trap3Sever...

Page 243: ...tup system System Information Eth0NetworkDiscovery Static Eth0NetworkAddress 10 20 11 32 Eth0NetworkMask 255 255 252 0 Eth0GatewayAddress 10 20 8 254 AdminTimeout 30 InactivityTimeout 0 LocalLogEnable...

Page 244: ...itch at convenient points and closes the Telnet session Always power cycle the switch after entering this command Authority Admin session Syntax shutdown Notes Always use this command to perform an or...

Page 245: ...or all port speeds independent of the capabilities of the transceiver This is the default The port must be in diagnostics mode to perform this test external Tests both the SerDes and transceiver for a...

Page 246: ...loopback plug must be installed for this test to pass test port x external 4 A series of test parameters are displayed on the screen Press the Enter key to accept each default parameter value or type...

Page 247: ...in some cases parameter is the number of bytes in each frame and the DataPattern parameter is the pattern in the payload Before running the test make sure that the device attached to the port can hand...

Page 248: ...s last reset and reset method A hot reset or non disruptive firmware activation does not reset the elapsed up time reported by this command Authority None Syntax uptime Examples The following is an ex...

Page 249: ...swords must be 8 20 characters Admin authority grants permission to use the Admin command to open an admin session from which all commands can be entered Without Admin authority you are limited to vie...

Page 250: ...lowing is an example of the User Add command SANbox admin user add Press q and the ENTER key to abort this command account name 1 15 chars user1 account password 8 20 chars please confirm account pass...

Page 251: ...n y The following is an example of the User List command SANbox admin user list User Ethernet Addr Port Logged in Since admin OB session1 10 20 68 108 1031 day month date time year admin OB session2 1...

Page 252: ...Command Displays the account name session number and switch domain ID for the Telnet session Authority None Syntax whoami Examples The following is an example of the Whoami command SANbox whoami User...

Page 253: ...aliases and ports devices in member_list A zone can have a maximum of 2000 members member_list can have any of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs can...

Page 254: ...ember_list member_list can have any of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs can be 1 239 port numbers can be 0 255 6 character hexadecimal device Fibre...

Page 255: ...23bd31 zone_set_1 wwn_221416 zone_set_1 wwn_2215c3 zone_set_1 wwn_0160ed zone_set_1 wwn_c001b0 zone_set_1 wwn_401248 zone_set_1 wwn_02402f zone_set_1 wwn_22412f zone_set_1 The following is an example...

Page 256: ...B Command Line Interface Zone Command B 134 59096 02 C S The following is an example of the Zone Zonesets command SANbox zone zonesets zone1 Current List of ZoneSets for Zone zone1 zone_set_1...

Page 257: ...ew zones zone_set Keywords activate zone_set Activates the zone set given by zone_set This keyword deactivates the active zone set Close the Zoning Edit session before using this keyword active Displa...

Page 258: ...e removed until the zone set has been deactivated rename zone_set_old zone_set_new Renames the zone set given by zone_set_old to the name given by zone_set_new You can rename the active zone set zones...

Page 259: ...B Command Line Interface Zoneset Command 59096 02 C B 137 A The following is an example of the Zoneset Zones command SANbox zoneset zones ssss Current List of Zones for ZoneSet ssss zone1 zone2 zone3...

Page 260: ...ion for the active zone set including component zones and zone members This keyword does not require an Admin session cancel Closes the current Zoning Edit session Any unsaved changes are lost clear C...

Page 261: ...Admin session list Lists all zoning definitions This keyword does not require an Admin session restore Reverts the changes to the zoning database that have been made during the current Zoning Edit ses...

Page 262: ...dmin zoning zoning cancel Zoning edit mode will be canceled Please confirm y n n y SANbox admin admin end The following is an example of the Zoning Limits command SANbox zoning limits Zoning Attribute...

Page 263: ...wwn_221416 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 10 00 00 00 c9 22 14 16 wwn_2215c3 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 10 00 00 00 c9 22 15 c3 Configured Zoning Information Zon...

Page 264: ...B Command Line Interface Zoning Command B 142 59096 02 C S Notes...

Page 265: ...gured Alias A named set of ports or devices An alias is not a zone and can not have a zone or another alias as a member AL_PA Arbitrated Loop Physical Address Arbitrated Loop A Fibre Channel topology...

Page 266: ...itch through the use of groups and security sets Domain ID User defined number that identifies the switch in the fabric Event Log Log of messages describing events that occur in the fabric Expansion P...

Page 267: ...nge with a target device In Order Delivery A feature that requires that frames be received in the same order in which they were sent Input Power LED A chassis LED that indicates that the switch logic...

Page 268: ...ments SANsurfer Switch Manager Switch management application Simple Network Management Protocol An application protocol that manages and monitors network communications and functions It also controls...

Page 269: ...associations that have established voluntary standards for controlling electromagnetic interference EMI Worldwide Name WWN A unique 64 bit address assigned to a device by the device manufacturer WWN W...

Page 270: ...SANbox 5600 Series Fibre Channel Switch Installation Guide Glossary 6 59096 02 C S Notes...

Page 271: ...B 9 create B 9 delete B 10 delete members B 10 display list B 10 display members B 10 rename B 10 Alias command B 9 altitude A 5 Arbitrated Loop Physical Address B 80 authentication B 28 authority B...

Page 272: ...ts 3 4 A 2 critical error 5 3 D Date command B 23 defaults alarm configuration B 50 port configuration B 49 RADIUS configuration B 52 security configuration B 53 services configuration B 52 Simple Net...

Page 273: ...Unit 6 1 A 3 File Transfer Protocol description 2 12 example 5 5 B 39 service 3 14 B 85 firmware failure 5 4 image file B 38 install with CLI 4 27 B 25 install with SANsurfer Switch Manager 4 26 list...

Page 274: ...tivity 2 7 2 8 Heartbeat 2 4 5 3 Input Power 2 4 5 2 Link Status 2 8 Logged In 2 6 5 7 power supply 2 10 System Fault 2 5 5 2 license key 2 6 3 6 4 28 B 24 Link control frame preference routing B 66 l...

Page 275: ...eset B 47 discovery B 87 gateway address B 87 interfaces B 94 IP address B 87 mask B 87 Network Time Protocol client B 88 interaction with Date command B 23 server address B 88 service 3 14 B 85 non c...

Page 276: ...urce loading A 4 supply 2 10 6 2 supply diagnostics 5 11 power on self test description 4 22 5 3 log B 97 Power Supply Fault LED 2 10 5 11 Power Supply Status LED 2 10 5 11 principal priority 3 7 swit...

Page 277: ...ges B 55 security set activate B 58 add member group B 58 copy B 58 create B 59 deactivate B 59 delete B 59 delete member group B 59 display B 59 display active B 54 B 58 display members B 59 rename B...

Page 278: ...5 4 processor A 2 system configuration change B 87 defaults B 53 display B 118 System Fault LED 2 5 5 2 T table mount 4 3 Telnet service 3 13 B 84 session timeout B 87 temperature error 5 6 operating...

Page 279: ...member port B 132 list B 132 list members B 132 name server 3 3 rename B 132 type B 132 Zone command B 131 zone set activate B 135 active B 138 add member zone B 135 copy B 135 create B 135 deactivat...

Page 280: ...SANbox 5600 Series Fibre Channel Switch Installation Guide Index 10 59096 02 C S Notes...

Reviews: