B – Command Line Interface
Set Config Command
B-68
59096-02 C
S
InbandEnabled
Inband management. Enables (True) or disables
(False) the ability to manage the switch over an ISL.
The default is True.
FDMIEnabled
Fabric Device Monitoring Interface. Enables (True) or
disables (False) the monitoring of target and initiator
device information. The default is True.
FDMIEntries
The number of device entries to maintain in the FDMI
database. Enter a number from 0–1000. The default
is 1000.
DefaultDomainID
Default domain ID. The default is 1.
DomainIDLock
Prevents (True) or allows (False) dynamic reassign-
ment of the domain ID. The default is False.
SymbolicName
Descriptive name for the switch. The name can be up
to 32 characters excluding #, semicolon (;), and
comma (,). The default is SANbox.
R_A_TOV
Resource Allocation Timeout Value. The number of
milliseconds the switch waits to allow two ports to
allocate enough resources to establish a link. The
default is 10000.
E_D_TOV
Error Detect Timeout Value. The number of millisec-
onds a port is to wait for errors to clear. The default is
2000.
PrincipalPriority
The priority used in the FC-SW-2 principal switch
selection algorithm. 1 is high, 255 is low. The default
is 254.
ConfigDescription
Switch configuration description. The configuration
description can be up to 32 characters excluding #,
semicolon (;), and comma (,). The default is
Config Default.
InteropMode
Propagates just the active zone set throughout the
fabric (Standard, FC-SW-2 compliant) or the entire
zoning database (Interop-1, non-compliant). The
default is Standard.
LegacyAddressFormat
Available only when the InteropMode parameter is
Interop-1, this parameter enables (True) or disables
(False) the use of legacy address formatting for inter-
operating with non-FC-SW-2 switches. The default is
False.
Table B-20. Set Config Switch Parameters (Continued)
Parameter
Description
Summary of Contents for SANbox 5600 Series
Page 10: ...Page x 59096 02 C SANbox 5600 Series Fibre Channel Switch Installation Guide S...
Page 28: ...1 Introduction Technical Support 1 18 59096 02 C S Notes...
Page 68: ...3 Planning Fabric Management 3 28 59096 02 C S Notes...
Page 112: ...5 Diagnostics Troubleshooting Recovering a Switch 5 16 59096 02 C S Notes...
Page 116: ...6 Removal Replacement Power Supply Removal and Replacement 6 4 59096 02 C S Notes...
Page 264: ...B Command Line Interface Zoning Command B 142 59096 02 C S Notes...
Page 270: ...SANbox 5600 Series Fibre Channel Switch Installation Guide Glossary 6 59096 02 C S Notes...
Page 280: ...SANbox 5600 Series Fibre Channel Switch Installation Guide Index 10 59096 02 C S Notes...