3–Managing Switches
Using the Switch Data Window
3-4
59264-02 B
Configured Admin State
Switch administrative state that is stored in the switch
configuration
Beacon Status
Beacon status. Switch LEDs are blinking (On) or not
(off).
Status Group
Operational State
Switch operational state: Online, Offline, Diagnostic,
Down
Administrative State
Current switch administrative state
Configured Admin State
Switch administrative state that is stored in the switch
configuration
Beacon Status
Beacon status. Switch LEDs are blinking (On) or not
(off).
Reason for Status
The reason for the operational state.
Temperature
Internal switch temperature °C
Fan 1 Status
Fan 1 status
Fan 2 Status
Fan 2 status
Power Supply 1 Status
Power supply 1 status
Power Supply 2 Status
Power supply 2 status
Temperature Failure Port
Shutdown
Non configurable (always enabled for this switch). All
ports are downed when the switch temperature
exceeds the Failure Temperature.
Warning Temperature
Non configurable temperature threshold (65° Celsius)
above which a warning condition alarm is generated.
Failure Temperature
Non configurable temperature threshold (70° Celsius)
above which a failure condition alarm is generated.
POST Status
Status from the most recent Power On Self Test
POST Fault Code
Fault code from the most recent Power On Self Test
Test Status
The current diagnostic test status of switch.
Test Fault Code
The code value for the last recorded diagnostic test
status recorded on the switch.
Network Group
Table 3-1. Switch Data Window Entries (Continued)
Entry
Description