5 – Switch Configuration
Displaying Switch Information
5-8
59263-01 A
S
Hardware Information
Enter the
Show Chassis
command to display the status of the switch hardware
including fans, power supplies, internal temperature, and Heartbeat LED status.
SANbox #> show chassis
Chassis Information
-------------------
BoardTemp (1) - Degrees Celsius 36
FanStatus (1) Good
FanStatus (2) Good
FanDirection (1) BackToFront
FanDirection (2) BackToFront
PowerSupplyStatus (1) Good
PowerSupplyStatus (2) Good
HeartBeatCode 1
HeartBeatStatus Normal
The HeartBeatCode and HeartBeatStatus entries indicate the Power-on Self Test
(POST) results revealed by the Heartbeat LED blink patterns. The result is normal
operation or a blink pattern indicating a critical error as described in
Table 5-1
.
Refer to the
SANbox 5802V Fibre Channel Switch Installation Guide
for more
information about the Heartbeat LED and its blink patterns.
Table 5-1. Heartbeat LED Activity
HeartBeatCode–HeartBeatStatus
Description
1–Normal
One blink per second–Normal operation
2–AppDied
Two blink cluster–Internal firmware failure
3–PostFailed
Three blink cluster–Fatal POST error
4–CorruptFilesystem
Four blink cluster–Configuration file system
error
5–Overheating
Five blink cluster– Over temperature
Summary of Contents for SANbox 5802V
Page 14: ...Page xiv 59263 01 A SANbox 5802V Fibre Channel Switch Command Line Interface Guide S ...
Page 50: ...4 Network Configuration Managing IP Security 4 20 59263 01 A S Notes ...
Page 82: ...5 Switch Configuration Managing Idle Session Timers 5 32 59263 01 A S Notes ...
Page 98: ...6 Port Configuration Testing a Port 6 16 59263 01 A S Notes ...
Page 148: ...11 Event Log Configuration Creating and Downloading a Log File 11 8 59263 01 A S Notes ...
Page 166: ...12 Call Home Configuration Resetting the Call Home Database 12 18 59263 01 A S Notes ...
Page 398: ...14 Command Reference Zoning Save 14 224 59263 01 A S Notes ...
Page 412: ...SANbox 5802V Fibre Channel Switch Command Line Interface Guide Index 14 59263 01 A S ...