background image

S i m p l i f y

59021-05 A

Page i

SANbox2-16 Fibre Channel Switch

Installation Guide

Summary of Contents for SANbox2-16 Fibre Channel

Page 1: ...S i m p l i f y 59021 05 A Page i SANbox2 16 Fibre Channel Switch Installation Guide ...

Page 2: ...r any errors that may appear in this document QLogic SANbox SANbox2 SANblade and SANsurfer are trademarks or registered trademarks of QLogic Corporation Solaris is a registered trademarks of Sun Microsystems Inc Pentium is a registered trademark of Intel Corporation Linux is a registered trademark of Linus Torvalds Microsoft Windows NT and Windows 2000 and Internet Explorer are registered trademar...

Page 3: ... 6 5 VCCI Class A Statement 1 6 1 6 6 BSMI Class A Statement 1 6 1 7 Laser Safety Information 1 7 1 8 Electrostatic Discharge Sensitivity ESDS Precautions 1 7 1 9 Accessible Parts 1 8 1 10 Pièces Accessibles 1 8 1 11 Zugängliche Teile 1 8 1 12 Technical Support 1 9 1 12 1 Availability 1 9 1 12 2 Training 1 9 1 12 3 Contact Information 1 9 Section 2 General Description 2 1 Chassis Controls and LEDs...

Page 4: ...ority and Domain ID Lock 3 2 3 2 2 Common Topologies 3 3 3 2 2 1 Cascade Topology 3 3 3 2 2 2 Mesh Topology 3 4 3 2 2 3 Multistage Topology 3 5 3 3 Performance 3 6 3 3 1 Distance 3 6 3 3 2 Bandwidth 3 7 3 3 3 Latency 3 7 3 4 Device Access 3 8 3 4 1 Soft Zones 3 9 3 4 2 Access Control List Hard Zones 3 9 3 4 3 Virtual Private Fabric Hard Zones 3 10 3 5 Fabric Management 3 10 3 6 Fabric Security 3 1...

Page 5: ...7 4 3 1 Using SANbox Manager to Install Firmware 4 17 4 3 2 Using the CLI to Install Firmware 4 18 4 3 3 Using FTP and the CLI to Install Firmware 4 19 4 4 Powering Down a Switch 4 20 Section 5 Diagnostics Troubleshooting 5 1 POST Diagnostics 5 1 5 1 1 Heartbeat LED Blink Patterns 5 1 5 1 1 1 Normal all pass 5 1 5 1 1 2 Maintenance Mode Pattern 5 2 5 1 1 3 Internal Firmware Failure Blink Pattern 5...

Page 6: ...witch Specifications A 1 A 2 Switch Maintainability A 2 A 3 Fabric Management A 3 A 4 Switch Dimensions A 3 A 5 Switch Electrical A 3 A 6 Switch Environmental A 4 A 7 Switch Regulatory Certifications A 4 A 8 Shortwave Laser SFP 1G 2G multi mode A 5 A 9 Longwave Laser SFP 1G 2G single mode A 6 Appendix B Command Line Interface B 1 Logging On to a Switch B 1 B 2 Command Syntax B 2 B 3 Commands B 3 A...

Page 7: ...73 Zoneset Command B 77 Zoning Command B 80 Glossary Index Figures Figure Page 2 1 SANbox2 16 Fibre Channel Switch 2 1 2 2 Chassis Controls and LEDS 2 2 2 3 Chassis LEDs 2 3 2 4 Fibre Channel Ports 2 4 2 5 SFP Transceiver 2 5 2 6 Port LEDs 2 5 2 7 Ethernet Port 2 8 2 8 Serial Port 2 8 2 9 Power Supply Components 2 9 2 10 Fans 2 10 3 1 Cascade with a Loop Topology 3 3 3 2 Mesh Topology 3 4 3 3 Mult...

Page 8: ...ort Latency 3 7 4 1 Management Workstation Requirements 4 1 B 1 Commands Listed by Authority Level B 3 B 2 Switch Configuration Defaults B 19 B 3 Port Configuration Defaults B 19 B 4 Alarm Threshold Configuration Defaults B 20 B 5 SNMP Configuration Defaults B 21 B 6 System Configuration Defaults B 22 B 7 Set Config Port Parameters B 25 B 8 Set Config Switch Parameters B 27 B 9 Set Config Threshol...

Page 9: ...s to consider when planning a fabric Section 4 explains how to install and configure the switch Section 5 describes the diagnostic methods and troubleshooting procedures Section 6 describes the removal replacement procedures for all field replaceable units FRUs Appendix A lists the switch specifications Appendix B describes the Telnet command line interface Please read the communications statement...

Page 10: ...re Channel Arbitrated Loop FC AL 2 Rev 6 8 Fibre Channel Private Loop SCSI Direct Attach FC PLDA NCITS TR 19 1998 Fibre Channel 10 bit Interface Rev 2 3 Definitions of Managed Objects for the Fabric Element in Fibre Channel Standard draft ietf ipfc fabric element mib 04 txt The Fibre Channel Standards are available from Global Engineering Documents 15 Inverness Way East Englewood CO 80112 5776 Pho...

Page 11: ...nweise Ein Warnhinweis weist auf das Vorhandensein einer Gefahr hin die möglicherweise Verletzungen zur Folge hat 4 3 4 6 6 1 Ein Vorsichtshinweis weist auf das Vorhandensein einer Gefahr hin die möglicherweise Geräteschäden zur Folge hat 4 3 6 4 1 5 Notes informatives relatives à la sécurité Une note informative Avertissement indique la présence d un risque pouvant entraîner des blessures 4 3 4 5...

Page 12: ...erference in which case the user will be required to correct the interference at their own expense Neither the provider nor the manufacturer is responsible for any radio or television interference caused by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15 of the F...

Page 13: ...1 1997 Safety of Information Technology Equipment Including Electrical Business Equipment EN60825 1 A11 1996 Safety of Laser Products Part 1 EN55022 1998 Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment EN55024 1 1998 Electromagnetic compatibility Generic immunity standard Part 1 Residential commercial and light industry IEC1000 4 2 1995 E...

Page 14: ...formation Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions 1 6 6 BSMI Class A Statement Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user will be required to take adequate measures ...

Page 15: ...ardous The International Electrotechnical Commission IEC 825 Laser Safety Standard requires labeling in English German Finnish and French stating that the product uses Class 1 lasers Because it is impractical to label the transceivers the following label is provided in this manual 1 8 Electrostatic Discharge Sensitivity ESDS Precautions The assemblies used in the switch chassis are ESD sensitive O...

Page 16: ...ommutateur SANbox2 16 Fibre Channel Switch sont les suivantes Interfaces aux media d interconnexion appelés SFP transceivers Alimentation s de courant Ventilateurs Se reporter à la Section 6 Procédures de retrait et remplacement pour plus de renseignements 1 11 Zugängliche Teile Nur die folgenden Teile im SANbox2 16 Fibre Channel Switch können kundenseitig ersetzt werden Schnittstellen für die Zwi...

Page 17: ...Logic offers the following technical training courses Switch Certification HBA Certification Each course is available at the training facility in Eden Prairie MN or at your local facility All courses include a Fibre Channel overview and sections on installation maintenance and topology solutions Each student receives a set of manuals and a CD ROM containing course training materials Upon successfu...

Page 18: ...1 Introduction Technical Support 1 10 59021 05 A Notes ...

Page 19: ...orts Ethernet port Serial port Power supplies Fans Fabric management Fabrics are managed with the SANbox Manager switch management application version 1 05 and the Command Line Interface CLI Refer to the SANbox2 8c 16 Switch Management User s Guide for information about using the SANbox Manager application Refer to Appendix B Command Line Interface for more information Figure 2 1 SANbox2 16 Fibre ...

Page 20: ...switch for maintenance purposes when flash memory or the resident configuration file is corrupted Refer to Recovering a Switch on page 5 12 for information about maintenance mode To place the switch in maintenance mode do the following 1 Isolate the switch from the fabric Open a Telnet session and enter the Shutdown command Refer to Shutdown Command on page B 65 2 Place both power supply switches ...

Page 21: ...temperature inside the switch This LED illuminates to indicate that the switch logic circuitry is overheating Refer to Section 5 Diagnostics Troubleshooting for information about troubleshooting over temperature conditions 2 1 3 2 Fan Fail LED Amber The Fan Fail LED indicates operational status of both fans This LED illuminates if the speed of either fan falls below the normal range Removing a fan...

Page 22: ...blink patterns 2 1 3 4 Input Power LED Green The Input Power LED indicates the voltage status at the switch logic circuitry This LED illuminates when the switch logic circuitry is receiving the proper DC voltages 2 2 Fibre Channel Ports Each SANbox2 16 switch has 16 Fibre Channel ports numbered 0 15 as shown in Figure 2 4 Each of these ports is served by a Small Form Factor Pluggable SFP transceiv...

Page 23: ...able This means that you can remove or install an SFP transceiver while the switch is operating without harming the switch or the transceiver However communication with the connected device will be interrupted Refer to Section 6 Removal Replacement for information about installing and removing SFP optical transceivers Figure 2 5 SFP Transceiver 2 2 2 Port LEDs Each data port has its own Logged In ...

Page 24: ...es that data is passing through the port Each frame that the port transmits or receives causes this LED to illuminate for 50 milliseconds This makes it possible to observe the transmission of a single frame When extending credits an Activity LED for a donor port will reflect the traffic of the recipient port Refer to Distance on page 3 6 for more information about extended credits and donor ports ...

Page 25: ...s as a proxy for the off loop device translating private frames into and from public frames Each TL_Port can proxy up to 63 off loop initiator devices or up to 64 off loop target and initiator devices The set of off loop devices are maintained in the TL_Port s translation entries list For a TL_Port connected to private target devices the switch firmware automatically creates an entry in the transl...

Page 26: ...ge the switch over an Ethernet connection using SANbox Manager the Command Line Interface CLI or SNMP The switch through which the fabric is managed is called the fabric management switch Figure 2 7 Ethernet Port 2 4 Serial Port The SANbox2 16 switch is equipped with an RS 232 serial port for maintenance purposes The serial port is located on the back of the switch under a small cover as shown in ...

Page 27: ...ptacle an On Off switch and two status LEDs as shown in Figure 2 9 After connecting a power supply to an AC voltage source and placing the power switch in the On position the power supply is energized and DC voltage is delivered to the switch logic circuitry Refer to Section 6 Removal Replacement for information about replacing a power supply Figure 2 9 Power Supply Components Table 2 1 Serial Por...

Page 28: ...to indicate that the power supply is producing DC voltage at the proper levels The Over Temperature LED illuminates to indicate that the power supply is overheating When a power supply overheats the switch extinguishes the Output Power LED and shuts down the power supply Refer to Section 5 Diagnostics Troubleshooting for information about troubleshooting over temperature conditions 2 6 Fans The sw...

Page 29: ...ts the following management tools Command Line Interface File Transfer Protocol FTP Simple Network Management Protocol SNMP The command line interface provides monitoring and configuration functions by which the administrator can manage the fabric and its switches Refer to Appendix B Command Line Interface for more information FTP provides the command line interface for exchanging files between th...

Page 30: ...2 General Description Switch Management 2 12 59021 05 A Notes ...

Page 31: ...full Fibre Channel addressing capability only the Arbitrated Loop Physical Address ALPA portion A TL_Port provides a proxy for a loop of private initiator or target devices allowing communication with off loop public and private devices Consider the number of private devices in the fabric and the number of off loop devices with which the private devices must communicate A TL_Port can support up to...

Page 32: ...signment of the domain ID on that switch Switches come from the factory with the domain ID set to 1 the domain ID lock set to FALSE and the principal priority set to 254 Refer to the SANbox2 8c 16 Switch Management User s Guide for information about changing the domain ID using SANbox Manager Refer to Set Config Command on page B 25 for information about changing the default domain ID domain ID lo...

Page 33: ...p reduces latency because any switch can route traffic in the shortest direction to any switch in the loop The loop also provides failover should a switch fail The cascade fabric shown in Figure 3 1 has the following characteristics Each chassis link contributes up to 200 MB s of bandwidth between chassis 400 MB s in full duplex However because of the sequential structure that bandwidth will be sh...

Page 34: ...sh fabric shown in Figure 3 2 has the following characteristics Each link contributes up to 200 MB s of bandwidth between switches 400 MB s in full duplex Because of multiple parallel paths there is less competition for this bandwidth than with a cascade or a Multistage topology Latency between any two device ports is no more than two chassis hops 40 Fibre Channel ports are available for devices F...

Page 35: ...witch by 200 MB s The Multistage fabric shown in Figure 3 3 has the following characteristics Each link contributes up to 200 MB s of bandwidth between chassis Competition for this bandwidth is less than that of a cascade topology but greater than that of the mesh topology Latency between any two device ports is three chassis hops 52 Fibre Channel ports are available for devices Figure 3 3 Multist...

Page 36: ...pes and SFP transceivers Each port is supported by a data buffer with a 12 credit capacity that is 12 maximum sized frames For fibre optic cables this enables full bandwidth over a distance of 20 kilometers at 1 Gbps 0 6 credits Km or 10 kilometers at 2 Gbps Gbps 1 2 credits Km Beyond this distance however there is some loss of efficiency because the transmitting port must wait for an acknowledgem...

Page 37: ...s between the connecting switches The switch guarantees in order delivery with any number of links between chassis 3 3 3 Latency Latency is a measure of how fast a frame travels from one port to another The factors that affect latency include transmission rate and the source destination port relationship as shown in Table 3 2 Table 3 1 Port to Port Transmission Combinations Source Port Rate Destin...

Page 38: ...ip in a zone can be defined by switch port number port Fibre Channel address or by device worldwide name WWN Devices can communicate only with devices that are members of the same zone A zone can be a member of more than one zone set Several zone sets can be defined for a fabric but only one zone set can be active at one time The active zone set determines the current fabric zoning A zoning databa...

Page 39: ...l port modes 3 4 2 Access Control List Hard Zones Access Control List ACL zoning divides the fabric for purposes of controlling discovery and inbound traffic ACL zoning is a type of hard zoning that is hardware enforced This type of zoning is useful for controlling access to certain devices without totally isolating them from the fabric Members can communicate with each other and transmit outside ...

Page 40: ...r of only one VPF zone VPF zone boundaries supersede both soft and ACL zone boundaries Membership can be defined only by domain ID and port ID VPF zoning supports all port modes 3 5 Fabric Management The SANbox Manager application and CLI execute on a management workstation that provides for the configuration control maintenance of the fabric Supported platforms include Windows Windows NT Solaris ...

Page 41: ...uthority permits only monitoring and display tasks Admin authority permits all management tasks including user administration Consider your fabric security needs who the system administrators will be and authority levels they should have Refer to Commands on page B 3 for more information about authority levels Refer to the User Command on page B 70 for information about creating user accounts Refe...

Page 42: ...3 Planning Fabric Security 3 12 59021 05 A Notes ...

Page 43: ...t workstations running SANbox Manager are described in Table 4 1 Telnet workstations require an RJ 45 Ethernet port or an RS 232 serial port and an operating system with a Telnet client 4 1 2 Switch Power Requirements Operating voltage requirements are as follows 90 to 137 Vac 47 to 63 Hz 180 to 265 Vac 47 to 63 Hz Table 4 1 Management Workstation Requirements Operating System Windows NT 2000 95 9...

Page 44: ...ng temperature range 10 to 40 C 50 104 F Relative humidity 25 80 non condensing 4 2 Installing a Switch Unpack the switch and accessories The SANbox2 16 product is shipped with the components shown in Figure 4 1 SANbox2 16 Fibre Channel Switch 1 with firmware installed Power cords 2 Rubber feet 4 Rack mount brackets 2 CD containing the SANbox Manager switch management application release notes and...

Page 45: ...nevenly loaded rack can become unstable possibly resulting in equipment damage or personal injury CAUTION If the switch is mounted in a closed or multi unit rack assembly make sure that the operating temperature inside the rack enclosure does not exceed the maximum rated ambient temperature Refer to Switch Environmental on page A 4 The switch must rest on rails or a shelf in the rack or cabinet Al...

Page 46: ... Racks Electrical Equipment 19 Inch and Associated Panels 2 Mount the brackets on the front or rear corners of the chassis as shown in Figure 4 2 3 Place the switch in the rack and secure it with four 10 32 x 625 machine screws not supplied Figure 4 2 Installing Rack Mount Brackets 4 2 2 Install SFP Transceivers The switch will support a variety of interconnection media Refer to SFP Transceivers o...

Page 47: ...rated at 10 Amps and be approved by UL and CSA For 250 Volt electrical service The cable must be rated at 10 Amps meet the requirements of H05VV F and be approved by VDE SEMKO and DEMKO AVERTISSEMENT Pour la sécurité de l utilisateur l appareil est livré avec un câble d alimentation trifilaire et une fiche Pour éviter toute secousse électrique enficher ce câble à une prise correctement mise à la t...

Page 48: ...itsanforderungen und sollte an einer vorschriftsmäßigen Schukosteckdose angeschlossen werden um die Gefahr eines elektrischen Schlages zu vermeiden Elektrosteckdosen die nicht richtig verdrahtet sind können gefährliche Hochspannung an den Metallteilen des switch Gehäuses verursachen Der Kunde trägt die Verantwortung für eine vorschriftsmäßige Verdrahtung und Erdung der Steckdose zur Vermeidung ein...

Page 49: ...e the results of the Power On Self Test POST The POST tests the condition of firmware memories data paths and switch logic circuitry and passes a blink code to the Heartbeat LED If the Heartbeat LED blinks steadily about once per second the POST was successful and you can continue with the installation process Any other blink pattern appears indicates that an error has occurred Refer to Heartbeat ...

Page 50: ...agement workstation to the switch RJ 45 Ethernet connector This requires a 10 100 Base T cross over cable as shown in Figure 4 3 With this method you can manage the switch with the SANbox Manager application or Command Line Interface Serial port connection from the management workstation to the switch RS 232 serial port connector This requires a null modem F F DB9 cable as shown in Figure 4 3 With...

Page 51: ...bric security The default account name and password are admin password SANbox2 Login admin Password 4 2 4 2 Serial Connection To establish a serial port connection do the following 1 Connect a null modem F F DB9 cable from a COM port on the management workstation to the RS 232 serial port on the switch 2 Configure the connection according to your platform For Windows a Open the HyperTerminal appli...

Page 52: ...box2 3 Log in to the switch If fabric security is disabled account names and passwords are not enforced Refer to the Set Setup Command on page B 38 for information about setting fabric security The default account name and password are admin password SANbox2 Login admin Password 4 2 5 Install SANbox Manager You can install SANbox Manager on the Windows Linux and Solaris platforms Your switch was s...

Page 53: ...htm file to open the SANsurfer Management Suite start page in your default browser 2 On the SANsurfer Management Suite start page choose the SANbox Switch Software button 3 On the SANbox Switch Software page scroll to the SANbox2 2Gb Series area 4 In the Windows column choose the SANbox Manager link to open the File Download window 5 You have a choice of running the installation file from the CD R...

Page 54: ...ng command mount mnt cdrom c Execute your web browser to view the Start_Here htm document using one of the following commands mozilla file mnt cdrom Start_Here htm or netscape file mnt cdrom Start_Here htm d The SANsurfer Management Suite start page opens in your default browser 2 On the SANsurfer Management Suite start page choose the SANbox Switch Software button 3 On the SANbox Switch Software ...

Page 55: ...e Start_Here htm file to open the SANsurfer Management Suite start page in your default browser 2 On the SANsurfer Management Suite start page choose the SANbox Switch Software button 3 On the SANbox Switch Software page scroll to the SANbox2 2Gb Series area 4 In the Solaris column choose the SANbox Manager link to open the Save As window 5 Enter a path name to save the sansurfer_solaris_install p...

Page 56: ...programs currently running and insert the SANbox2 Installation Disk into the management workstation CD ROM drive 2 Open the File Manager and double click on the CD ROM icon 3 Double click the SANbox_Manager folder then double click the Linux folder 4 Double click the executable file and follow the SANbox Manager installation instructions 4 2 11 SANbox2 Installation Disk Solaris Installation To ins...

Page 57: ...efault fabric security is disabled and therefore account names and passwords are not enforced Refer to the Set Setup Command on page B 38 for information about setting fabric security 4 Open the Switch menu and select Switch Properties In the Switch Properties window enter a chassis name Accept the default domain ID and choose the OK button 5 Open the Switch menu and select Network Properties In t...

Page 58: ... switch The default port mode is GL_Port Refer to the SANbox2 8c 16 Switch Management User s Guide for more information about configuring ports You can also configure ports using the CLI Refer to Appendix B Command Line Interface for more information 4 2 14 Cable Devices to the Switch Connect cables to the SFP transceivers and their corresponding devices and then energize the devices Device host b...

Page 59: ...an FTP server you can open a Telnet session and load and unpack the firmware image file using the CLI Image command Refer to Using the CLI to Install Firmware on page 4 18 When using the CLI on a workstation without an FTP server you must open an FTP session through the switch to load the image file then open a Telnet session to unpack it with the CLI Image command Refer to Using FTP and the CLI t...

Page 60: ... running an FTP server Enter the following command to retrieve the firmware file from the specified IP address cli admin image fetch username 10 0 0 254 firmwarefilenametoload firmwarefilenameonswitch Connected to 10 0 0 254 331 Password required for username Password 230 User username logged in bin 200 Type set to I verbose Verbose mode off 5 Enter the following command to display the list of fir...

Page 61: ...address and switchname is the switch name associated with the IP address 4 Enter the following account name and password user images password images 5 Activate binary mode and copy the firmware image file on the switch ftp bin ftp put filename 6 Close the FTP session ftp quit 7 Establish communications with the switch using the CLI Enter one of the following on the command line telnet xxx xxx xxx ...

Page 62: ...lash memory cli admin image unpack filename 12 Reset the switch to activate the new firmware This will close the Telnet session by default cli admin reset 4 4 Powering Down a Switch Simply unplugging the switch from the power source does not allow the switch to complete executing tasks and could lead to flash memory corruption For this reason open a Telnet session and use the Shutdown command to i...

Page 63: ...ternal data loopback test on all ports Access and integrity test on the ASIC During the POST the switch logs any errors encountered Some POST errors are fatal others are non fatal The switch uses the Heartbeat LED and the Logged In LED to indicate switch and port status A fatal error disables the switch so that it will not operate A non fatal error allows the switch to operate but disables the por...

Page 64: ...tal error blink pattern is 3 blinks per second followed by a two second pause The 3 blink error pattern indicates that a fatal error has left the switch inoperable If a fatal error occurs contact your authorized maintenance provider 5 1 1 5 Configuration File System Error Blink Pattern A configuration file system error blink pattern is 4 blinks per second followed by a two second pause The 4 blink...

Page 65: ...er 6 Remake Filesystem and press the Enter key to recreate the configuration file 0 Exit 1 Image Unpack 2 Reset Network Config 3 Reset Password File 4 Copy Log Files 5 Remove Switch Config 6 Remake Filesystem 7 Reset Switch Option 6 6 When the recreate process is complete select option 7 to reset the switch and exit maintenance mode 7 If a previously saved configuration file is available for the s...

Page 66: ... the following on the command line telnet xxx xxx xxx xxx or telnet switchname where xxx xxx xxx xxx is the switch IP address and switchname is the switch name associated with the IP address f A Telnet window opens prompting you for a login Enter an account name and password The default account name and password are admin password g Open an admin session to acquire the necessary authority cli admi...

Page 67: ... per second as shown in Figure 5 2 Error Flashes at roughly twice per second as shown in Figure 5 2 Figure 5 2 Logged In LED Indications If a Logged In LED shows an error indication review the alarm log for messages regarding the affected port You can inspect the alarm log using the Alarm data tab in SANbox Manager faceplate display or the Show Alarm command Pertinent alarm log messages will point...

Page 68: ... Switch Properties window Reset the port If the condition remains continue 2 Compare the RA_TOV ED_TOV RT_TOV timeout values for all switches in the fabric using the Show Config Switch command or the Switch data tab of the SANbox Manager topology display Is each timeout value the same on every switch Yes Continue No Correct the timeout values on the offending switches using the Set Config Switch c...

Page 69: ...ng its operational state to down Port errors can be caused by the following Thresholds are too low or the sample interval is too small Faulty Fibre Channel port cable Faulty SFP Faulty port Fault device or HBA Review the alarm log to determine if excessive port errors are responsible for disabling the port Look for a message that mentions one of the monitored error types indicating that the port h...

Page 70: ...e port pass the test Yes Continue No Replace the SFP and repeat the test If the port does not pass the test contact your authorized maintenance provider Otherwise continue 3 Replace the Fibre Channel port cable Is the problem corrected Yes Complete No Continue 4 Inspect the device to which the affected port is connected and confirm that the device and its HBA are working properly Make repairs and ...

Page 71: ...lluminated Input Power LED is extinguished Fan Fail LED is illuminated Output Power LED is extinguished Power supply Over Temperature LED is illuminated Note The chassis and power supply Over Temperature LEDs are different The chassis LED indicates an over temperature condition in the switch logic circuitry the power supply LED indicates an over temperature condition in the power supply Output Pow...

Page 72: ...Input Power LED Is Extinguished The Input Power LED illuminates to indicate that the switch logic circuitry is receiving proper voltages If the Input Power LED is extinguished inspect the Output Power LED Is the Output Power LED illuminated Yes Contact your authorized maintenance provider No Refer to Output Power LED Is Extinguished on page 5 11 5 2 3 Fan Fail LED is Illuminated The Fan Fail LED i...

Page 73: ...s If the condition remains continue 4 Replace the power supply Refer to Section 6 Removal Replacement If the condition remains contact your authorized maintenance provider 5 2 5 Power Supply Over Temperature LED is Illuminated The power supply Over Temperature LED illuminates to indicate that the power supply is overheating If the power supply Over Temperature LED illuminates do the following 1 In...

Page 74: ...witch configuration parameters to the factory default values Reset the switch To recover a switch do the following 1 Place the switch in maintenance mode Do the following a Power down the switch b Press and hold the Maintenance button with a pointed tool then power up the switch All chassis LEDs will illuminate then extinguish leaving only the Input Power LED illuminated Release the button 2 Allow...

Page 75: ... Maintenance Image Unpack This option unpacks and installs new firmware when the current firmware has become corrupt Before using this option you must load the new firmware image file onto the switch The steps to install new firmware using this option are as follows 1 Place the switch in maintenance mode Refer to the procedure for maintenance mode in Recovering a Switch on page 5 12 2 Use FTP to l...

Page 76: ...tion parameters to the factory defaults except for user accounts and zoning Refer to Table B 2 though Table B 6 for the factory default values 5 3 7 Maintenance Remake Filesystem In the event of sudden loss of power it is possible that the switch configuration may become corrupt The file system on which the configuration is stored must be re created This option resets the switch to the factory def...

Page 77: ...y with the same or equivalent type recommended by the manufacturer Dispose of the used battery according to the manufacturer s instructions WARNUNG Bei unsachgemäß ausgetauschter Batterie besteht Explosionsgefahr Die Batterie nur mit der gleichen Batterie oder mit einem äquivalenten vom Hersteller empfohlenen Batterietyp ersetzen Die gebrauchte Batterie gemäß den Herstelleranweisungen entsorgen AV...

Page 78: ...ently press the transceiver into the port to release the tension then pull on the release tab or lever and remove the transceiver Different transceiver manufacturers have different release mechanisms Consult the documentation for your transceiver To install insert the transceiver into the port and gently press until it snaps in place as shown in Figure 6 1 Figure 6 1 SFP Transceiver Installation N...

Page 79: ... supplies are the same unit To remove the power supply grasp the power supply latch handle and pull firmly to release the latches and disengage the modular connector Slide the power supply out of its bay as shown in Figure 6 2 To install a power supply slide the power supply into the bay with the latch handle on top Press the power supply firmly into place until it is fully seated then push the la...

Page 80: ...de the fan out of its bay as shown in Figure 6 2 Figure 6 3 Fan Removal When replacing a fan consider the following The left and right fans are interchangeable However you must orient the fan so that the modular connector aligns with the mating connector in the switch as shown in Figure 6 4 Replacement fans must be compatible with the switch air flow direction Air flow direction for switch model S...

Page 81: ...th the switch air flow direction 2 Align the modular connector toward the inside of the switch as shown in Figure 6 4 3 Slide the fan into the bay until it is firmly seated and confirm that the air flow is correct Fasten the screws Figure 6 4 Fan Installation for Switch Model SB2A 16B Modular Connector Part Number Label ...

Page 82: ...6 Removal Replacement Fans 6 6 59021 05 A Notes ...

Page 83: ...PH 3 FC AL Rev 4 5 FC AL 2 Rev 7 0 FC FLA FC GS 3 FC FG FC PLDA FC Tape FC VI FC SW 2 Fibre Channel Element MIB RFC 2837 Fibre Alliance MIB Version 3 0 Fibre Channel Classes of Service Classes 2 and 3 Modes of Operation Fibre Channel Classes 2 and 3 connectionless Port Types F_Port FL_Port TL_Port E_Port G_Port GL_Port Port Characteristics All ports are auto discovering and self configuring Number...

Page 84: ...peed 1 0625 or 2 125 Gigabits second Maximum Frame Size 2148 bytes 2112 byte payload System Processor 266 MHz Pentium processor Fabric Latency best case 0 5 µsec Fabric Point to Point Bandwidth 212 or 424 MB s full duplex Fabric Aggregate Bandwidth 64 Gb s for a single switch Maintenance Strategy Field Replaceable Units SFP transceivers Power supplies Fans Diagnostics Power On Self Test POST tests...

Page 85: ...nnector 10 100BASE T cable Switch Agent Allows a network management station to obtain configuration values traffic information and failure data pertaining to the Fibre Channels via SNMP through the Ethernet interface Width Height Depth 17 0 19 inch rack mount 1 75 18 0 Weight 18 lbs Power source loading 1 9 Amps maximum at 90 to 137 Vac 0 95 Amps maximum at 180 to 265 Vac Heat Output maximum 170 w...

Page 86: ...ting Non operating Magnitude during after along any axis 2 54 mm 1 5 14 Hz 0 1G 14 300 Hz 5 500 Hz random 2 09 G rms 10 minutes Shock Operating Non operating Magnitude during after along any axis 1 g for 15 msec 8 g for 15 msec Air flow Two fans front to back or back to front depending on the switch model Safety Standards UL1950 CSA 22 2 No 950 EN60950 Emissions Standards FCC Part 15B Class A VCCI...

Page 87: ...ibre Channel 100 M6 SN I 50 µm multimode Fibre Channel 200 M5 SN I or 200 M6 SN I 62 5 µm multimode Wavelength 830 860 nm Transmit Power 10 dBm minimum Receiver Sensitivity 16 dBm average Distance 500 meters maximum using 50 micron fiber 300 meters maximum using 62 5 micron fiber Safety DHHS 21 CFR J IEC 825 1 CENELEC EN 60825 1 VDE Standard Small Form Factor Pluggable Multisource Agreement ...

Page 88: ... Color coding Blue exposed connector surfaces Cable Fibre Channel 100SM LC L 9 µm single mode Wavelength 1270 13 5 nm Transmit Power 10 dBm minimum Receiver Sensitivity 20 dBm average Distance 2 meters to 10 kilometers Safety DHHS 21 CFR J IEC 825 1 CENELEC EN 60825 1 VDE Standard Small Form Factor Pluggable Multisource Agreement ...

Page 89: ...er an account name and password Switches come from the factory with the following user account already defined Account name admin Password password Authority Admin This user account provides full access to the switch and its configuration After planning your fabric management needs and creating your own user accounts consider changing the password for this account Refer to Commands on page B 3 for...

Page 90: ... Consider the following rules and conventions Commands and keywords are lowercase and case sensitive Commands with keywords require one of those keywords Required keyword values appear in standard font value Optional values are shown in italics value Underlined portions of the keyword in the command format indicate the abbreviated form that can be used For example the Delete keyword can be abbrevi...

Page 91: ...evel in Table B 1 Note Admin authority is enforced only if fabric security is enabled By default fabric security is disabled Refer to Set Setup Command on page B 38 System keyword for more about setting fabric security Table B 1 Commands Listed by Authority Level User Authority Commands Admin Authority Command Help History Ps Quit Show Show Config Show Log Show Perf Show Setup Uptime Whoami B 11 B...

Page 92: ...el Keywords start Opens the admin session end Closes the admin session The Logout Shutdown and Reset Switch commands will also end an admin session cancel Terminates an Admin session opened by another user Use this keyword with care because it terminates the Admin session without warning the other user and without saving pending changes Notes Closing a Telnet window during an admin session does no...

Page 93: ...ce Fibre Channel address hex 16 character hexadecimal worldwide port name WWPN with the format xx xx xx xx xx xx xx xx The application verifies that the alias format is correct but does not validate that such a port device exists copy alias_source alias_destination Creates a new alias named alias_destination and copies the membership into it from the alias given by alias_source create alias Create...

Page 94: ... members from the alias given by alias members can have one of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs and port numbers are in decimal Ports are numbered beginning with 0 6 character hexadecimal device Fibre Channel address hex 16 character hexadecimal worldwide port name WWPN for the device with the format xx xx xx xx xx xx xx xx rename alias_old alia...

Page 95: ...ed configdata which contains the system configuration information To download this file open an FTP session log in with account name password of images for both and type get configdata cancel Terminates the current configuration edit session without saving changes that were made copy config_source config_destination Copies the configuration given by config_source to the configuration given by conf...

Page 96: ...ame value the configuration you chose for the Config Edit command is used The switch supports up to 10 configurations including the default configuration Notes If you edit the active configuration changes will be held in suspense until you reactivate the configuration or activate another configuration Examples The following shows an example of how to open and close a Config Edit session SANbox2 ad...

Page 97: ...mmCCYY You must reset the switch for the new date to take effect Authority Admin to change the date User to display the date Syntax date MMDDhhmmCCYY Keywords MMDDhhmmCCYY Specifies the date this requires an admin session If you omit MMDDhhmmCCYY the current date is displayed this is available with User authority Examples The following is an example of the Date command SANbox2 date Thu Mar 13 07 5...

Page 98: ...two versions Authority Admin Syntax fallback Notes The Show Switch command displays the available firmware versions and the currently active version After executing the Fallback command reset the switch for the firmware to be placed in effect Examples The following is an example of the Fallback command SANbox2 admin start SANbox2 admin fallback Reverting to previous software image Please confirm y...

Page 99: ...fied command all Displays a list of all available commands including command variations Examples The following is an example of the Help Set command SANbox2 help set set SET_OPTIONS There are many attributes that can be set Type help with one of the following to get more information set alarm set beacon set blade set config blade set config port set config ports set config switch set config thresh...

Page 100: ... History display Enter partial command string to re execute a command that matches the command string Enter to re execute the most recent command Examples The following is an example of the History command SANbox2 history 1 show switch 2 date 3 help set 4 history SANbox2 3 help set set SET_OPTIONS There are many attributes that can be set Type help with one of the following to get more information...

Page 101: ...nd stores it on the switch with the file name given by file_destination The image file is retrieved from the device with the IP address given by ip_address and an account name given by account_name If an account name needs a password to access the device the system will prompt you for it list Displays the list of image files that reside on the switch unpack file Installs the firmware file given by...

Page 102: ...4 59021 05 A Lip Command Reinitializes the specified loop port Authority Admin Syntax lip port_number Keywords port_number The number of the port to be reinitialized Examples The following is an example of the Lip command SANbox2 admin lip 2 ...

Page 103: ...t name You must open an admin session to change the password for an account name other than your own If you omit account_name you will be prompted to change the password for the current account name Examples The following is an example of the Passwd command SANbox2 admin passwd user2 Press q and the ENTER key to abort this command account OLD password account NEW password 4 20 chars please confirm...

Page 104: ...E ELAPSED COMMAND 298 292 0 0 00 00 00 59 42 cns 299 292 0 0 00 00 00 59 42 ens 300 292 0 0 00 00 00 59 42 dlog 301 292 0 3 00 00 53 59 42 ds 302 292 0 2 00 00 29 59 42 mgmtApp 303 292 0 0 00 00 02 59 42 nserver 304 292 0 0 00 00 00 59 42 mserver 305 292 0 1 00 00 15 59 42 util 306 292 0 0 00 00 04 59 42 eport 307 292 1 2 00 02 53 59 41 PortApp 308 292 0 0 00 00 01 59 41 zoning 309 292 0 0 00 00 0...

Page 105: ...B Command Line Interface Quit Command 59021 05 A B 17 Quit Command Closes the Telnet session Authority User Syntax quit exit or logout ...

Page 106: ...hold configuration default values factory Resets switch alarm threshold zoning SNMP zoning configuration and system configuration settings to the factory default values The switch configuration is activated automatically Refer to Table B 2 through Table B 6 port port_number Reinitializes the port given by port_number Ports are numbered beginning with 0 snmp Resets the SNMP configuration settings t...

Page 107: ...c Name SANbox2 R_T_TOV 100 R_A_TOV 10000 E_D_TOV 2000 FS_TOV 5000 DS_TOV 5000 Principal Priority 254 System Description Undefined Configuration Last Saved By Initial Configuration Last Saved On Initial Table B 3 Port Configuration Defaults Parameter Default Admin State Online Link Speed Auto Port Type GL TL_Port Mode TLTargetMode ISL Security Any Symbolic Name Port ALFairness False ARB_FF False In...

Page 108: ...n Defaults Parameter Default ThresholdMonitoringEnabled False CRCErrorsMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 25 1 10 DecodeErrorsMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 25 0 10 ISLMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 2 0 10 LoginMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 5 1 10 Table B 3 Port Conf...

Page 109: ...dow True 100 5 10 Table B 5 SNMP Configuration Defaults Parameter Default Contact Undefined Location Undefined Description Undefined Trap 1 5 Address Trap 1 10 0 0 254 Traps 2 5 0 0 0 0 Trap 1 5 Port Undefined Trap 1 5 Severity Warning Trap 1 5 Enabled False ObjectID 1 3 6 1 4 1 1663 1 1 1 1 11 AuthFailureTrap False Table B 4 Alarm Threshold Configuration Defaults Continued Parameter Default ...

Page 110: ...faults Parameter Default Ethernet Network IP Address 10 0 0 1 Ethernet Network IP Mask 255 0 0 0 Ethernet Gateway Address 10 0 0 254 Ethernet Network Discovery Static Admin Timeout 30 minutes SecurityEnabled False LocalLogEnabled True RemotelogEnabled False RemoteLogHostIPAddress Undefined ...

Page 111: ... following on Enables the flashing beacon off Disables the flashing beacon config option Sets switch port alarm threshold and zoning configuration parameters Refer to the Set Config Command on page B 25 log option Specifies the type of entries to be entered in the event log Refer to the Set Log Command on page B 34 pagebreak state Specifies how much information is displayed on the screen at a time...

Page 112: ...age B 38 switch state Temporarily changes the administrative state for all ports on the switch to the state given by state The previous Set Config Switch settings are restored after a switch reset or a reactivation of a switch configuration state can be one of the following online Places all ports online offline Places all ports offline diagnostics Prepares all ports for testing Examples The follo...

Page 113: ...7 describes the port parameters ports port_number Initiates an editing session in which to change configuration parameters for all ports based on the configuration for the port given by port_number If you omit port_number port 0 is used For each parameter enter a new value or press the Enter key to accept the current value shown in brackets Enter q to cancel the configuration Table B 7 describes t...

Page 114: ... acquire from donor ports FANEnable Fabric address notification Enables True or disables False the communication of the FL_Port address port name and node name to the logged in NL_Port LCFEnable Link control frame preference R_CTL 0xC MFSEnable Multi Frame Sequence bundling MFS_TOV MFS limit for camp on MSEnable Management Server enable on this port NoClose Don t close unless another device arbitr...

Page 115: ... to manage the switch over an ISL DefaultDomainID Default domain ID setting DomainIDLock Prevents True or allows False dynamic reassignment of the domain ID SymbolicName Descriptive name R_T_TOV Receiver Transmitter Timeout Value Specifies the number of milliseconds a port is to wait to receive a response from another port The default is 100 R_A_TOV Resource Allocation Timeout Value The number of ...

Page 116: ...rm is cleared when the threshold monitoring detects that the error rate has fallen below the falling threshold PrincipalPriority The priority used in the FC SW 2 principal switch selection algorithm 1 is high 255 is low ConfigDescription The name for the configuration The default is undefined Table B 9 Set Config Threshold Parameters Parameter Description Threshold Monitoring Enabled Master enable...

Page 117: ...hreshold Falling Trigger The event count below which a falling threshold alarm is logged The switch will not generate another falling threshold alarm for that event until the count exceeds the rising threshold and descends again below the falling threshold Sample Window The period of time in seconds in which to count events Table B 10 Set Config Zoning Parameters Parameter Description AutoSave Ena...

Page 118: ...Auto Auto PortType TL GL G F FL Donor GL TLPortMode 1 TLTargetMode 2 TLInitiatorMode TLInitiatorMode ISLSecurity Any Ours None Any SymPortName string max 32 chars Port2 ALFairness True False False ARB_FF True False False InteropCredit decimal value 0 255 0 ExtCredit decimal value 0 65535 0 FANEnable True False True LCFEnable True False False MFSEnable True False False MFS_TOV decimal value 10 2048...

Page 119: ...1000 msec 100 R_A_TOV decimal value 100 100000 msec 10000 E_D_TOV decimal value 10 20000 msec 2000 FS_TOV decimal value 100 100000 msec 5000 DS_TOV decimal value 100 100000 msec 5000 PrincipalPriority decimal value 1 255 254 ConfigDescription string max 32 chars The following is an example of the Set Config Threshold command SANbox2 admin start SANbox2 admin config edit SANbox2 admin config set co...

Page 120: ...llingTrigger decimal value 0 1000 1 SampleWindow decimal value 1 1000 sec 10 LogoutMonitoringEnabled True False True RisingTrigger decimal value 1 1000 5 FallingTrigger decimal value 0 1000 1 SampleWindow decimal value 1 1000 sec 10 LOSMonitoringEnabled True False True RisingTrigger decimal value 1 1000 100 FallingTrigger decimal value 0 1000 5 SampleWindow decimal value 1 1000 sec 10 Finished con...

Page 121: ...will follow Enter a new value or simply press the ENTER key to accept the current value If you wish to terminate this process before reaching the end of the list press q or Q and the ENTER key to do so AutoSave True False True Default All None All Finished configuring attributes This configuration must be saved see config save command and activated see config activate command before it can take ef...

Page 122: ...e Archives the log entries to a file on the switch named logfile that can be downloaded from the switch using FTP To download the log file open an FTP session log in with account name password of images for both and type get logfile clear Clears all log entries component list Specifies one or more components to monitor for events Use spaces to delimit values in the list Choose one or more of the f...

Page 123: ... do not use this setting with the Component keyword set to All None Monitors none of the severity levels port port_list Specifies one or more ports to monitor for events Choose one of the following values port_list Specifies port or ports to monitor Use spaces to delimit values in the list Ports are numbered beginning with 0 All Specifies all ports None Disables monitoring on all ports restore Ret...

Page 124: ...n the Port Component and Level keywords assigned to the current configuration The logging continues until you enter the Set Log Stop command stop Stops logging of events Notes To maintain optimal switch performance do not set the Component keyword to All and the Level keyword to Info at the same time ...

Page 125: ...ysical Address ALPA or to all ALPAs on the arbitrated loop alpa can be a specific ALPA or the keyword ALL to choose all ALPAs clear Clears the counters on the specified port enable Sends a Loop Port Enable LPE to all ALPAs on the arbitrated loop speed transmission_speed Specifies the transmission speed for the specified port Choose one of the following port speed values 1Gb s One gigabit per secon...

Page 126: ...s undefined Trap 1 5 Address Specifies the workstation IP address to which SNMP traps are sent The default address for trap 1 is 10 0 0 254 The default address for traps 2 5 is 0 0 0 0 Trap 1 5 Port Specifies the workstation port to which SNMP traps are sent Trap 1 5 Severity Specifies the severity level to use when monitoring trap events The default is Warning Trap 1 5 Enabled Specifies whether t...

Page 127: ...ss Internet Protocol IP address for the Ethernet port Eth0NetworkMask Subnet mask address for the Ethernet port Eth0GatewayAddress IP address gateway Eth0NetworkDiscovery Boot Method 1 Static 2 Bootp 3 DHCP 4 RARP AdminTimeout Specifies the amount of time in minutes the switch waits before terminating an idle Admin session Zero 0 disables the time out threshold The default is 30 the maximum is 144...

Page 128: ...s with formatting and current values will follow Enter a new value or simply press the ENTER key to accept the current value If you wish to terminate this process before reaching the end of the list press q or Q and the ENTER key to do so Trap Severity Options unknown emergency alert critical error warning notify info debug mark Contact string max 32 chars sysContact undefinted Location string max...

Page 129: ...tes with formatting and current values will follow Enter a new value or simply press the ENTER key to accept the current value If you wish to terminate this process before reaching the end of the list press q or Q and the ENTER key to do so Eth0NetworkAddress dot notated IP Address 10 0 0 1 Eth0NetworkMask dot notated IP Address 255 255 255 0 Eth0GatewayAddress dot notated IP Address 10 0 0 254 Et...

Page 130: ...main_id support switch topology users version Keywords about Displays an introductory set of information about operational attributes of the switch This keyword is equivalent to the Version keyword alarm Displays the last 200 alarm entries broadcast Displays the broadcast tree information and all ports that are currently transmitting and receiving broadcast frames chassis Displays chassis componen...

Page 131: ...es are in 1K block units ns option Displays name server information for the specified option If you omit option name server information for the local domain ID is displayed option can have the following values all Displays name server information for all switches and ports domain_id Displays name server information for the switch given by domain_id domain_id is a switch domain ID port_id Displays ...

Page 132: ...y this port ClassXWordsOut Number of class x words sent by this port DecodeError Decoding error detected FBusy Number of times the switch sent a F_BSY because Class 2 frame could not be delivered within ED_TOV time Number of class 2 and class 3 fabric busy F_BSY frames generated by this port in response to incoming frames This usually indicates a busy condition on the fabric or N_port that is prev...

Page 133: ...mber of synchronization losses 100 ms detected by this port A loss of synchronization is detected by receipt of an invalid transmission word PrimSeqErrors Primitive sequence errors detected EportConnects Shows the count of the number of times an E_Port connected through ISL negotiation RxLinkResets Number of link reset primitives received from an attached device RxOfflineSeq Number of offline sequ...

Page 134: ...d from the screen and used for diagnosing problems This keyword is intended for use at the request of your authorized maintenance provider The commands that are executed include the following Date Alias List Config List Date History Ps Show About Alarm Backtrace Chassis Config Port Config Switch Dev Dev Settings Domains Donor Fabric Log Log Settings Lsdb Mem Ns Perf Port Setup Mfg Setup Snmp Setup...

Page 135: ...he following is an example of the Show Chassis command SANbox2 show chassis Chassis Information BoardTemp 1 Degrees Celsius 32 BoardTemp 2 Degrees Celsius 36 FanStatus 1 Good FanStatus 2 Good PowerSupplyStatus 1 Good PowerSupplyStatus 2 Good The following is an example of the Show Domains command SANbox2 show domains Principal switch is local 10 00 00 c0 dd 00 90 6b Domain ID List Domain 22 0x16 W...

Page 136: ...Trap3Port 162 Trap3Severity warning Trap3Enabled False Trap4Address 0 0 0 0 Trap4Port 162 Trap4Severity warning Trap4Enabled False Trap5Address 0 0 0 0 Trap5Port 162 Trap5Severity warning Trap5Enabled False ObjectID 1 3 6 1 4 1 1663 1 1 1 1 11 AuthFailureTrap False The following is an example of the Show NS local domain command SANbox2 show ns Seq Domain Port Port No ID ID Type COS PortWWN NodeWWN...

Page 137: ...2 show interface eth0 Link encap Ethernet HWaddr 00 C0 DD 00 BD ED inet addr 10 20 68 107 Bcast 10 20 68 255 Mask 255 255 255 0 UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 4712 errors 0 dropped 0 overruns 0 frame 0 TX packets 3000 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 100 RX bytes 415313 405 5 Kb TX bytes 716751 699 9 Kb Interrupt 11 Base address 0xfcc0 lo...

Page 138: ...cStatus SyncLost MaxCredit 0 XmitterEnabled False OperationalState Online ALInit 0 FlowErrors 0 PrimSeqErrors 0 ALInitError 0 FReject 0 RxLinkResets 0 Class2FramesIn 0 InvalidCRC 0 RxOfflineSeq 0 Class2FramesOut 0 InvalidDestAddr 0 TotalErrors 0 Class2WordsIn 0 LIP_AL_PD_AL_PS 0 TotalLIPsRecvd 0 Class2WordsOut 0 LIP_F7_AL_PS 0 TotalLinkResets 0 Class3FramesIn 0 LIP_F7_F7 0 TotalOfflineSeq 0 Class3...

Page 139: ... System command SANbox2 admin show setup system System Information Eth0NetworkAddress 10 20 11 112 Eth0NetworkMask 255 255 252 0 Eth0GatewayAddress 10 20 8 254 Eth0NetworkDiscovery Static AdminTimeout 30 SecurityEnabled True LocalLogEnabled True RemoteLogEnabled True RemoteLogHostAddress 10 20 11 106 ...

Page 140: ... 42 2001 SWImageVersion 2 build date V0 4 6 18 Fri Jun 15 10 22 09 2001 ActiveConfiguration default ActiveSWImage 2 AdminState Online AdminModeActive False BeaconOnStatus False OperationalState Online PrincipalSwitchRole False BoardTemp 1 Degrees Celsius 32 BoardTemp 2 Degrees Celsius 36 SwitchDiagnosticsStatus Passed SwitchTemperatureStatus Normal The following is an example of the Show Topology ...

Page 141: ...rtID 650100 PortWWN 20 01 00 c0 dd 00 91 11 PortType F Remote Link Information Device 0 NodeWWN 50 80 02 00 00 06 d5 38 PortType NL Description NULL IPAddress 0 0 0 0 Device 1 NodeWWN 20 00 00 20 37 2b 08 c9 PortType NL Description NULL IPAddress 0 0 0 0 Device 2 Description NULL IPAddress 0 0 0 0 Device 3 NodeWWN 20 00 00 20 37 2b 05 c9 PortType NL Description NULL IPAddress 0 0 0 0 ...

Page 142: ...on QLogic SANbox2 FC Switch Eth0NetworkAddress 10 0 0 1 use set setup system to update FCNetworkAddress 0 0 0 0 use set setup system to update MACAddress 12 34 56 78 ab cd WorldWideName 10 00 00 c0 dd 00 90 a4 SymbolicName SANbox2 SWImageVersion V255 4 1 121 SWImageBuiltDate Mon Jul 29 19 42 47 2002 DiagnosticsStatus Passed SecurityEnabled False ...

Page 143: ... omitted all ports are specified switch Displays configuration parameters for the switch threshold Displays alarm threshold parameters for the switch zoning Displays zoning configuration parameters for the switch Examples The following is an example of the Show Config Port command SANbox2 show config port 3 Configuration Name default Port Number 3 AdminState Online LinkSpeed Auto PortType GL TLPor...

Page 144: ...lse SymbolicName SANbox2 16 N_11 107 R_T_TOV 100 R_A_TOV 10000 E_D_TOV 2000 FS_TOV 5000 DS_TOV 5000 PrincipalPriority 254 ConfigDescription QLogic SANbox2 FC Switch ConfigLastSavedBy guest IB session10 ConfigLastSavedOn Mon Nov 18 15 10 03 2002 The following is an example of the Show Config Threshold command SANbox2 show config threshold Configuration Name default Threshold Configuration Informati...

Page 145: ...bled True RisingTrigger 5 FallingTrigger 1 SampleWindow 10 LogoutMonitoringEnabled True RisingTrigger 5 FallingTrigger 1 SampleWindow 10 LOSMonitoringEnabled True RisingTrigger 100 FallingTrigger 5 SampleWindow 10 The following is an example of the Show Config Zoning command SANbox2 show config zoning Configuration Name default Zoning Configuration Information AutoSave True Default All ...

Page 146: ...or on a component which is not defined no entry is made in the log options Displays the options used to set the component and log level attributes port Displays the ports being monitored for events If an event occurs which is of the defined level and on a defined component but not on a defined port no entry is made in the log settings Displays the current settings for component level and port This...

Page 147: ... 09 36 54 861 1989 I Eport 0xdd00b8b6 304 4 Port 0 8 Send ing init hello 330 Wed Jan 25 09 36 54 861 1989 I Eport 0xdd00b8b6 304 4 Port 0 8 Proc essing EFP oxid 0x8 331 Wed Jan 25 09 36 54 861 1989 I Eport 0xdd00b8b6 304 4 Port 0 8 Epor t State E_A2_IDLE 332 Wed Jan 25 09 36 54 861 1989 I Eport 0xdd00b8b6 304 4 Port 0 8 EFP WWN 0x100000c0dd00b845 len 0x30 333 Wed Jan 25 09 36 54 864 1989 I Eport 0...

Page 148: ...mber Displays continuous performance data in bytes second transmitted for the set of 16 ports that include port_number Type q and press the Enter key to stop the display frame port_number Displays continuous performance data in total frames second transmitted and received for the set of 16 ports that include port_number Type q and press the Enter key to stop the display inframe port_number Display...

Page 149: ...0 0 0 0 0 0 12 0 0 0 0 0 0 13 0 0 0 0 0 0 14 0 7K 7K 0 245 245 15 136M 58K 136M 68K 1K 70K The following is an example of the Show Perf Byte command SANbox2 show perf byte Displaying bytes sec total Press q and the ENTER key to stop display 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 0 0 0 0 0 0 0 137M 58K 0 0 0 0 8K 137M 0 0 0 0 0 0 0 0 136M 58K 0 0 0 0 8K 136M 0 0 0 0 0 0 0 0 135M 58K 0 0 0 0 7K 135...

Page 150: ... system Displays the current system settings Examples The following is an example of the Show Setup Mfg command SANbox2 show setup mfg Manufacturing Information BoardSerialNumber 000781428 BrandName QLogic BuildDate Unknown ChassisPartNumber Unknown ChassisSerialNumber S01450034 MACAddress 00 c0 dd 00 bc 09 PlanarPartNumber Unknown SwitchSymbolicName SANbox2 SwitchWWN 10 00 00 c0 dd 00 bc 08 Syste...

Page 151: ...C Switch Trap1Address 10 0 0 254 Trap1Port 162 Trap1Severity warning Trap1Enabled False Trap2Address 0 0 0 0 Trap2Port 162 Trap2Severity warning Trap2Enabled False Trap3Address 0 0 0 0 Trap3Port 162 Trap3Severity warning Trap3Enabled False Trap4Address 0 0 0 0 Trap4Port 162 Trap4Severity warning Trap4Enabled False Trap5Address 0 0 0 0 Trap5Port 162 Trap5Severity warning Trap5Enabled False ObjectID...

Page 152: ...ow Setup System command SANbox2 show setup system System Information Eth0NetworkAddress 10 0 0 1 Eth0NetworkMask 255 255 255 0 Eth0GatewayAddress 10 0 0 254 Eth0NetworkDiscovery Static AdminTimeout 30 SecurityEnabled False LocalLogEnabled True RemoteLogEnabled False RemoteLogHostAddress 10 0 0 254 ...

Page 153: ...h at convenient points and closes the Telnet session Always power cycle the switch after entering this command Authority Admin Syntax shutdown Notes Always use this command to effect an orderly shut down before removing power from the switch Failure to do so could corrupt the flash memory and the switch configuration ...

Page 154: ...is the default The port must be in diagnostics mode to perform this test external Tests both the SerDes and SFP The port must be in diagnostics mode to perform this test and a loopback plug must be installed in the SFP online Tests one online port cancel Cancels the online test in progress status Displays the status of a test in progress or if there is no test in progress the status of the test th...

Page 155: ... has been chosen and the command executed a message on the screen will appear detailing the test results 7 After the test is run put the port back into online state by entering the following command x port number and pressing the Enter key set port x state online 8 To verify port is back online enter the following command and press the Enter key The contents of the AdminState field should display ...

Page 156: ...unning the test make sure that the device attached to the port can handle the test parameters SANbox2N107 admin test x online A list of attributes with formatting and current values will follow Enter a new value or simply press the ENTER key to accept the default value If you wish to terminate this process before reaching the end of the list press q or Q and the ENTER key to do so TestLength decim...

Page 157: ...ommand Displays the elapsed time since the switch was last reset and reset method Authority User Syntax uptime Examples The following is an example of the Uptime command SANbox2 uptime Elapsed up time 0 day s 2 hour s 28 min s 44 sec s Reason last reset NormalReset ...

Page 158: ...switch can have a maximum of 15 user accounts Account names are limited to 15 characters passwords are limited to 31 characters delete account_name Deletes the account name given by account_name from the switch list Displays the list of users currently logged in and their session numbers Provides the same function as the Show Users command This keyword is valid for User authority and does not requ...

Page 159: ...count password should this account have admin authority y n n y OK to add user account user3 with admin authority Please confirm y n n y The following is an example of the User Delete command SANbox2 admin user del user3 The user account will be deleted Please confirm y n n y The following is an example of the User List command SANbox2 admin user list Current list of users logged in admin OB sessi...

Page 160: ...mi Command Displays the account name session number and switch domain ID for the Telnet session Authority User Syntax whoami Examples The following is an example of the Whoami command SANbox2 whoami User name admin session2 Switch name SANbox2 Switch domain ID 1 ...

Page 161: ...n have one of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs and port numbers are in decimal Ports are numbered beginning with 0 6 character hexadecimal device Fibre Channel address hex 16 character hexadecimal worldwide port name WWPN with the format xx xx xx xx xx xx xx xx Alias name The application verifies that the members format is correct but does not v...

Page 162: ...ing with 0 6 character hexadecimal device Fibre Channel address hex 16 character hexadecimal worldwide port name WWPN with the format xx xx xx xx xx xx xx xx Alias name rename zone_old zone_new Renames the zone given by zone_old to the zone given by zone_new type zone zone_type Specifies the zone type given by zone_type to be assigned to the zone name given by zone If you omit the zone_type the sy...

Page 163: ...23bd31 zone_set_1 wwn_221416 zone_set_1 wwn_2215c3 zone_set_1 wwn_0160ed zone_set_1 wwn_c001b0 zone_set_1 wwn_401248 zone_set_1 wwn_02402f zone_set_1 wwn_22412f zone_set_1 The following is an example of the Zone Members command SANbox2 zone members wwn_b0241f Current List of Members for Zone wwn_b0241f 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 21 00 00 e0 8b 02 41 2f ...

Page 164: ...B Command Line Interface Zone Command B 76 59021 05 A The following is an example of the Zone Zonesets command SANbox2 zone zonesets zone1 Current List of ZoneSets for Zone wwn_b0241f zone_set_1 ...

Page 165: ...oning Edit session before using this keyword active Displays the name of the active zone set This keyword is available with User authority and does not require a Zoning Edit session add zone_set zone_list Adds a list of zones and aliases given by zone_list to the zone set given by zone_set Zone and alias names are delimited by spaces in zone_list This keyword requires a Zoning Edit session copy zo...

Page 166: ...en deactivated This keyword requires a Zoning Edit session rename zone_set_old zone_set_new Renames the zone set given by zone_set_old to the name given by zone_set_new You can rename the active zone set This keyword requires a Zoning Edit session zones zone_set Displays all zones that are members of the zone set given by zone_set This keyword is available with User authority and does not need a Z...

Page 167: ...B Command Line Interface Zoneset Command 59021 05 A B 79 The following is an example of the Zoneset Zones command SANbox2 zoneset zones ssss Current List of Zones for ZoneSet ssss zone1 zone2 zone3 ...

Page 168: ...py of the zoning database This keyword does not affect the non volatile zoning database However if you enter the Zoning Clear command followed by the Zoning Save command the non volatile zoning database will be cleared from the switch The preferred method for clearing the zoning database from the switch is the Reset Zoning command edit Opens a Zoning Edit session history Displays a history of zoni...

Page 169: ...ges This does not apply if you entered the Zoning Clear command during the Zoning Edit session Examples The following is an example of the Zoning Edit command SANbox2 admin start SANbox2 admin zoning edit SANbox2 admin zoning SANbox2 admin zoning zoning cancel Zoning edit mode will be canceled Please confirm y n n y SANbox2 admin admin end The following is an example of the Zoning List command SAN...

Page 170: ...c9 22 15 c3 Configured Zoning Information ZoneSet Zone ZoneMember wwn wwn_b0241f 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 21 00 00 e0 8b 02 41 2f wwn_23bd31 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 10 00 00 00 c9 23 bd 31 wwn_221416 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 10 00 00 00 c9 22 14 16 wwn_2215c3 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 10 00 00 00 c9 22 15 c...

Page 171: ...sical Address AL_PA A unique one byte valid value assigned during loop initialization to each NL_Port on a Loop ARB_FF When ARB_FF is enabled it causes the switch to send the ARB_FF primitive when it is in monitoring mode rather than idles The only reason to do this is since the ARB_FF has less bit transitions than does an idle it produces less EMI It has no other effect True False ASIC Applicatio...

Page 172: ...ternal switch processor and the results of the Power On Self Test Initiator The device that initiates a data exchange with a target device In Order Delivery A feature that requires that frames be received in the same order in which they were sent Input Power LED A chassis LED that indicates that the switch logic circuitry is receiving proper DC voltages InteropCredit This variable determines the n...

Page 173: ...formance when there is a single L_Port device connected to the switch True False Output Power LED A power supply LED that indicates that the power supply is providing DC voltage to the switch Over Temperature LED A chassis LED or a power supply LED that indicates that the switch or power supply is overheating POST Power On Self Test Power On Self Test POST Diagnostics that the switch chassis perfo...

Page 174: ...or Interference VIEnable FC VI When enabled VI preference frames will be transmitted ahead of other frames True False Worldwide Name WWN A unique 64 bit address assigned to a device by the device manufacturer WWN Worldwide Name Zone A set of ports or devices grouped together to control the exchange of information Zone Set A set of zones grouped together The active zone set defines the zoning for a...

Page 175: ...Alias command B 5 altitude A 4 Arbitrated Loop Physical Address 3 1 B 37 authority 3 11 B bandwidth 3 7 beacon B 23 brackets 4 2 4 4 broadcast B 42 buffer credit 3 6 A 2 C cable 10 100 Base T 4 8 10 100 Base T crossover cable 4 8 fibre optic 3 1 null modem F F DB9 4 8 cascade topology 3 3 chassis air flow A 4 diagnostics 5 9 LEDs 2 3 marking A 4 shock A 4 status B 42 vibration A 4 classes of servi...

Page 176: ...agement 3 10 A 3 management switch 2 8 management workstation 4 1 point to point bandwidth A 2 ports 2 7 security 3 11 4 10 factory defaults 5 14 B 18 Fallback command B 10 Fan Fail LED 2 3 5 10 fans 2 10 6 4 fatal error 5 1 5 2 fiber optic cable 3 1 Fibre Channel ports 2 4 protocols A 1 field replaceable unit 6 1 File Transfer Protocol 4 19 5 3 firmware failure 5 2 fallback version B 10 install w...

Page 177: ...B 34 clear B 34 copy 5 14 event B 34 power on self test B 46 logged in users B 47 Logged In LED 2 6 5 5 login limit B 1 loop port B 14 Loop Port Bypass B 37 Loop Port Enable B 37 M maintainability A 2 maintenance blink pattern 5 2 exit 5 13 interface A 3 menu 5 13 mode 2 2 5 2 5 12 strategy A 2 Maintenance button 2 2 5 12 management workstation 2 8 4 8 manufacturer information B 62 marking A 4 med...

Page 178: ...ower on self test description 5 1 log B 46 results 4 7 principal priority 3 2 switch 3 2 Ps command B 16 Q Quit command B 17 R rack mount 4 3 recovering a switch 5 12 regulatory certifications A 4 remake filesystem 5 14 removal replacement 6 1 Reset command B 18 RS 232 port 2 8 rubber feet 4 2 S safety standards A 4 SANbox Manager 2 11 SANbox Manager installation Linux 4 12 4 14 Solaris 4 13 4 14 ...

Page 179: ...7 private initiators 2 7 private targets 2 7 topology cascade 3 3 mesh 3 4 Multistage 3 5 transceiver 2 5 4 4 6 2 translated loop port 2 7 translation entries list 2 7 transmission rate 3 6 3 7 U Uptime command B 69 user account 3 11 B 1 authority 3 11 B 3 interface A 2 logged in B 47 User command B 70 V ventilation 2 10 vibration A 4 Virtual Private Fabric zone 3 10 voltage fluctuations A 4 opera...

Page 180: ...delete member zone B 78 display B 78 display active B 77 display members B 78 display zones B 74 rename B 78 Zoneset command B 77 zoning configuration B 29 configuration display B 55 database 3 8 B 18 edit B 80 history B 80 limits 3 8 B 80 list definitions B 81 revert changes B 81 save edits B 81 Zoning command B 80 ...