B – Command Line Interface
Set Config Command
59021-05 A
B-29
zoning
Initiates an editing session in which to change switch zoning attributes. The
system displays each parameter one line at a time and prompts you for a value.
For each parameter, enter a new value or press the Enter key to accept the
current value shown in brackets.
Rising Trigger
The event count above which a rising
threshold alarm is logged. The switch will
not generate another rising threshold
alarm for that event until the count
descends below the falling threshold and
again exceeds the rising threshold.
Falling Trigger
The event count below which a falling
threshold alarm is logged. The switch will
not generate another falling threshold
alarm for that event until the count
exceeds the rising threshold and
descends again below the falling
threshold.
Sample Window
The period of time in seconds in which to
count events.
Table B-10. Set Config Zoning Parameters
Parameter
Description
AutoSave
Enables (On) or disables (Off) the
saving of changes to active zone set in
the switch’s permanent memory.
Changes are always saved in the
switch’s temporary memory.
Default
Enables (All) or disables (None)
communication among the switch’s
ports/devices and the fabric in the
absence of an active zone set.
Table B-9. Set Config Threshold Parameters (Continued)
Parameter
Description
Summary of Contents for SANbox2-16 Fibre Channel
Page 1: ...S i m p l i f y 59021 05 A Page i SANbox2 16 Fibre Channel Switch Installation Guide ...
Page 18: ...1 Introduction Technical Support 1 10 59021 05 A Notes ...
Page 30: ...2 General Description Switch Management 2 12 59021 05 A Notes ...
Page 42: ...3 Planning Fabric Security 3 12 59021 05 A Notes ...
Page 82: ...6 Removal Replacement Fans 6 6 59021 05 A Notes ...