5 – Getting Started
Setting Up SANsurfer iSCSI HBA Manager
IS0054602-00 B
5-17
A
If something has changed and the SANsurfer iSCSI HBA Manager update
behavior configuration is set to update when the poll or host status alarms occur
(see
“Specifying Whether the Configuration Refreshes When Host and Target
Status Alarms Occur” on page 5-19
), theSANsurfer iSCSI HBA Manager user
interface then retrieves the latest information from the agent.
Specifying the HBA Polling Interval
The HBA polling interval is the length of elapsed time between polling events to
HBAs on a host.
To set the HBA polling interval:
1.
On the SANsurfer iSCSI HBA Manager main window HBA tree, select the
HBA port (or HBA, device, or LUN connected to the host).
2.
Do one of the following:
On the
Host
menu, click
HBA Poll Interval
.
Right-click the selected HBA port (or HBA, device, or LUN connected
to the host) in the HBA tree, and then on the shortcut menu, click
HBA
Poll Interval
.
The Polling Setting dialog box (
Figure 5-9
) opens, and shows the name of
the host in the title bar.
Figure 5-9 Polling Setting Dialog Box (HBA)
3.
In the
Interval
box, type the HBA polling interval. The range is 1 second to
3600 seconds (1 hour). The default is 30 seconds.
4.
To set the polling interval, click
OK
. To close the Polling Setting dialog box
without changing the polling interval, click
Cancel
.