QME700P v1.0
QMAXZ 2009
- 7 -
Power requirements:
QME700P
180V ~ 260V AC - 50Hz ~ 60Hz - 725Watts
Power lead Connection.
Wire Colour
Pin connection
Symbol
Yellow / Green
AC Earth (ground)
╧
Blue AC
Neutral
N
Brown AC
Live
L
6.2 Fuse replacement
When the fixtures main fuse is blown it can be replaced with a new 31x 6.35mm fuse, 15A/250v.
1. Disconnect the fixture from the mains supply.
2. Open the fuse holder on the fixture power panel by turning the cap counter clockwise using a
Philips head screwdriver.
3. Replace the defective fuse and close the fuse holder by putting the cap back in and turning it
clockwise until it is locked tightly.
4. Connect the mains power again and turn on the fixture to check proper operation.
There are also two fuses on the main PCB board inside the fixture, for how to replace this please contact
your dealer.
6.3 Signal Connections
The QMAXZ QME700P fixtures have both 5 pin XLR and Ethercon RJ45 sockets. For the pin-layout see
the following table.
Pin-Layout
Pin
5 pin XLR
1 Earth
2
Signal – (Cold)
3
(Hot)
4 No
connection
5 No
connection
Summary of Contents for QME700P
Page 1: ...USER MANUAL ENGLISH Version 1 0 ME700P Q QMAXZ Lighting 2009 all rights reserved www qmaxz com...
Page 2: ...QME700P v1 0 QMAXZ 2009 1...
Page 12: ...QME700P v1 0 QMAXZ 2009 11 7 2 Function Menu QME700P...
Page 13: ...QME700P v1 0 QMAXZ 2009 12...
Page 14: ...QME700P v1 0 QMAXZ 2009 13...
Page 15: ...QME700P v1 0 QMAXZ 2009 14...
Page 16: ...QME700P v1 0 QMAXZ 2009 15...
Page 17: ...QME700P v1 0 QMAXZ 2009 16...
Page 18: ...QME700P v1 0 QMAXZ 2009 17...
Page 19: ...QME700P v1 0 QMAXZ 2009 18...
Page 26: ...QME700P v1 0 QMAXZ 2009 25 10 2 Photometric Data QME700P...
Page 29: ...QME700P v1 0 QMAXZ 2009 26 10 3 Dimensional Drawings...