LUN
Enabled
The LUN is active for connection
and is visible to authenticated
initiators.
Disabled
The LUN is inactive and is invisible
to the initiators.
B utto
n
Na m e
De s c ription
Deactiva
te
Deactivate a ready or connected target. Note that the
connection from the initiators will be removed.
Activate
Activate an offline target.
Modify
Modify the target settings: target alias, CHAP information,
and checksum settings.
Modify the LUN settings: LUN allocation, name, disk volume
directory, etc.
Delete
Delete an iSCSI target. All the connections will be removed.
Disable
Disable an LUN. All the connections will be removed.
Enable
Enable an LUN.
Unmap
Unmap the LUN from the target. You must disable the LUN
before unmapping it. When you click this button, the LUN
will be moved to "Un-Mapped iSCSI LUN List".
Map
Map the LUN to an iSCSI target. This option is only available
on the "Un-Mapped iSCSI LUN List".
View
View the connection status of an iSCSI target.