background image

7.

Power on the NAS.

Replacing Memory Modules

The TS-hx77XU-RP has four memory slots. You can increase the memory capacity of the NAS by upgrading
the memory module.

Use only QNAP modules of the same type and capacity to maintain system performance and stability. You
can purchase QNAP memory modules from authorized resellers.

Replacing Memory Modules on the TS-h977XU-RP

Important

QNAP recommends installing modules in pairs to run dual-channel mode.

• Ensure that each memory channel uses identical modules. See table below for details:

Channel name

Slot numbering

Channel A

Slots 1, 2

Channel B

Slots 3, 4

• Install the pairs in sequence and follow the assigned slots for each pair.

• When installing one module use the slot furthest from the CPU (slot 4).

• Install memory modules in groups of two or four. When installing two memory modules,

install the memory in memory slots 2 and 4. When installing four modules, install the
memory in slots 2,4 and then slots 1, and 3.

For details on slot numbering, see 

System Board

.

Warning

TS-hx77XU-RP User Guide

Installation and Configuration   

27

Summary of Contents for TS-h1277XURP

Page 1: ...TS hx77XU RP TS h977XU RP TS h1277XU RP TS h1677XU RP TS h2477XU RP User Guide Document Version 2 01 06 2021 ...

Page 2: ...ules 27 Replacing Expansion Cards 34 Hot Swapping Redundant Power Supply Units 42 Installing Handles on the TS h977XU RP 44 Rail Kits 45 Expansion Unit Installation 45 QuTS hero Installation 51 Installing QuTS hero Using Qfinder Pro 52 Installing QuTS hero Using the Cloud Key 54 4 Basic Operations Power Button 57 Reset Button 57 LEDs 58 Audio Alert 59 5 Troubleshooting Forcing Qfinder Pro or myQNA...

Page 3: ...7 Notices Limited Warranty 64 Disclaimer 64 GNU Public License 64 CE Notice 72 UKCA Notice 72 FCC Notice 72 VCCI Notice 73 BSMI Notice 73 SJ T 11364 2006 73 2 ...

Page 4: ... the user has a basic understanding of storage and backup concepts Document Conventions Symbol Description Notes provide default configuration settings and other supplementary information Important notes provide information on required configuration settings and other critical information Tips provide recommendations or alternative methods of performing tasks or configuring settings Warnings provi...

Page 5: ...nce of encrypted file transfers Hardware Specifications Tip Model specifications are subject to change without prior notice To see the latest specifications go to https www qnap com Ordering P N Drive bays Memory Power supply TS h977XU RP 3700X 32G 9 AMD Ryzen 7 3700X Redundant TS h1277XU RP 3700X 32G 12 AMD Ryzen 7 3700X Redundant TS h1277XU RP 3700X 128G 12 AMD Ryzen 7 3700X Redundant TS h1677XU...

Page 6: ... SATA 6 Gbps TS h1677XU RP 16 x 3 5 inch SATA 6 Gbps TS h2477XU RP 24 x 3 5 inch SATA 6 Gbps Note The drive bays are backward compatible with SATA 3 Gbps drives Drive compatibility 3 5 inch bays 3 5 inch SATA hard disk drives 2 5 inch SATA hard disk drives 2 5 inch SATA solid state drives 2 5 inch bays 2 5 inch SATA hard disk drives 2 5 inch SATA solid state drives Important 2 5 inch drive trays o...

Page 7: ...y USB ports 4 x USB 3 2 Gen 1 Type A 1 x USB 3 2 Gen 2 10Gbps 5V 1A Type A 4 x USB 3 2 Gen 1 Type A 1 x USB 3 2 Gen 2 10Gbps 5V 3A Type C 1 x USB 3 2 Gen 2 10Gbps 5V 1A Type A Interface Buttons Power Reset Dimensions Form factor 1U Rackmount 2U Rackmount TS h1677XU RP 3U Rackmount TS h2477XU RP 4U Rackmount Dimensions H x W x D 43 3 x 482 6 x 505 54 mm 1 70 x 19 00 x 19 90 in 88 3 x 482 x 562 mm 3...

Page 8: ...W 100 240V AC 50 60 Hz TS h2477XU RP 2 x 800W 100 240V AC 50 60 Hz System battery CR2032 lithium battery 3V 225 mAh Important Dispose of used batteries according to local regulations or the instructions of the battery manufacturer Sound level 43 8 db A 37 2 db A TS h1677XU RP 46 6 db A TS h2477XU RP 27 5 db A Note The sound level was tested at a bystander position which is within one meter of the ...

Page 9: ...rives TS h977XU RP 32 TS h1277XU RP 36 TS h1677XU RP 64 TS h2477XU RP 96 Screws for 3 5 inch drives TS h977XU RP 16 TS h1277XU RP 48 TS h1677XU RP 64 TS h2477XU RP 96 Quick Installation Guide QIG 1 Components Front Panel TS h977XU RP No Component No Component 1 Status LED 3 Drive LEDs 2 LAN LED 4 Power button TS hx77XU RP User Guide Product Overview 8 ...

Page 10: ... 1 Drive LEDs 4 LAN LED 2 Power button 5 Expansion unit LED 3 Status LED TS h1677XU RP TS h2477XU RP No Component No Component 1 Power button 4 Expansion unit LED 2 Status LED 5 Drive LEDs 3 LAN LED TS hx77XU RP User Guide Product Overview 9 ...

Page 11: ...2 USB 3 2 Gen 2 Type A port 8 Ethernet port 2 GbE RJ45 3 Ethernet port 1 GbE RJ45 9 USB 3 2 Gen 1 Type A ports 4 Ethernet port 6 10GBase T RJ45 10 Ethernet port 4 10GbE SFP 5 Ethernet port 5 10GBase T RJ45 11 Reset button 6 Power supply unit 1 TS h1277XU RP TS hx77XU RP User Guide Product Overview 10 ...

Page 12: ...w profile covers 12 Ethernet port 4 10GbE SFP 6 Power supply unit 1 13 Reset button 7 Power supply unit 2 TS h1677XU RP No Component No Component 1 Power supply unit 1 7 USB 3 2 Gen 2 Type C port 2 Power supply unit 2 8 USB 3 2 Gen 1 Type A ports 3 PCIe full height covers 9 Ethernet port 3 10GbE SFP 4 Ethernet port 1 GbE RJ45 10 Ethernet port 4 10GbE SFP 5 Ethernet port 2 GbE RJ45 11 Reset button ...

Page 13: ...r supply unit 2 8 USB 3 2 Gen 2 Type A port 3 PCIe full height covers 9 USB 3 2 Gen 2 Type C port 4 Ethernet port 4 10GbE SFP 10 USB 3 2 Gen 1 Type A ports 5 Ethernet port 3 10GbE SFP 11 Reset button 6 Ethernet port 1 GbE RJ45 System Board TS h977XU RP TS hx77XU RP User Guide Product Overview 12 ...

Page 14: ... 3 Memory slot 3 Channel B DIMM 3 TS h1277XU RP No Component No Component 1 PCIe slot 1 PCIe 3 0 x4 5 Memory slot 4 Channel B DIMM 4 2 PCIe slot 2 PCIe 3 0 x8 6 Memory slot 3 Channel B DIMM 3 3 PCIe slot 3 PCIe 3 0 x4 7 Memory slot 2 Channel A DIMM 2 4 PCIe slot 4 PCIe 3 0 x8 Note A dual port 10Base T expansion card is installed on this PCIe slot 8 Memory slot 1 Channel A DIMM 1 TS hx77XU RP User ...

Page 15: ... 3 Channel B DIMM 3 3 PCIe slot 3 PCIe 3 0 x4 7 Memory slot 2 Channel A DIMM 2 4 PCIe slot 4 PCIe 3 0 x8 8 Memory slot 1 Channel A DIMM 1 TS h2477XU RP No Component No Component 1 PCIe slot 1 PCIe 3 0 x4 5 Memory slot 4 Channel B DIMM 4 2 PCIe slot 2 PCIe 3 0 x8 6 Memory slot 3 Channel B DIMM 3 TS hx77XU RP User Guide Product Overview 14 ...

Page 16: ... 2 Channel A DIMM 2 4 PCIe slot 4 PCIe 3 0 x4 Note A dual port 10GbE SFP expansion card is installed on this PCIe slot 8 Memory slot 1 Channel A DIMM 1 Drive Numbering TS h977XU RP 3 5 inch Trays TS h977XU RP 2 5 inch Trays TS hx77XU RP User Guide Product Overview 15 ...

Page 17: ...TS h1277XU RP TS h1677XU RP TS hx77XU RP User Guide Product Overview 16 ...

Page 18: ...ips 1 or 2 screwdriver Anti static wrist strap Safety Information The following instructions help ensure personal safety and environmental safety Read these instructions carefully before performing any operations General Instructions The device should be stored in a secure location with restricted access controlled through the use of a tool lock and key or any means of security Only qualified skil...

Page 19: ...mage to components ensure that you replace the existing battery with a battery of the same type Dispose of used batteries properly according to local regulations or the instructions of the battery manufacturer Moving Parts Moving fan blades Keep your body parts away from moving fan blades while the device is connected to a power source Moving components Keep your body parts away from other moving ...

Page 20: ...ch Hard Drives or Solid State Drives on 3 5 inch Trays Installing 2 5 inch Solid State Drives on 2 5 inch Trays on the TS h977XU RP 6 Connect the power cord and all applicable cables 7 Power on the NAS 8 Install QuTS hero For details see QuTS hero Installation 9 Log on to QuTS hero TS hx77XU RP User Guide Product Overview 19 ...

Page 21: ...nch hard drives and 2 5 inch solid state drives Installing 3 5 inch Hard Drives on 3 5 inch Trays Warning Installing a drive and installing QuTS hero deletes all data on the drive Moving fan blades Keep your hands and other body parts away from moving fan blades Other moving components Keep your hands and other body parts away from other moving components 1 Power off the NAS 2 Remove the drive tra...

Page 22: ... on the tray so that the holes on the bottom of the drive are aligned with the holes on the bottom of the tray b Attach the screws 4 Load the tray into the bay a Insert the tray into the bay TS hx77XU RP User Guide Installation and Configuration 21 ...

Page 23: ...letes all data on the drive Moving fan blades Keep your hands and other body parts away from moving fan blades Other moving components Keep your hands and other body parts away from other moving components 1 Power off the NAS 2 Remove the drive tray a Pull the handle to release the tray b Pull the tray out TS hx77XU RP User Guide Installation and Configuration 22 ...

Page 24: ... on the tray so that the holes on the bottom of the drive are aligned with the holes on the bottom of the tray b Attach the screws 4 Load the tray into the bay a Insert the tray into the bay TS hx77XU RP User Guide Installation and Configuration 23 ...

Page 25: ...uTS hero deletes all data on the drive Moving fan blades Keep your hands and other body parts away from moving fan blades Other moving components Keep your hands and other body parts away from other moving components 1 Power off the NAS 2 Remove the case cover a Remove the screws b Lift the cover up TS hx77XU RP User Guide Installation and Configuration 24 ...

Page 26: ...l the tray out 4 Install a drive on the tray a Place the drive on the tray so that the holes on the bottom of the drive are aligned with the holes on the bottom of the tray b Attach the screws TS hx77XU RP User Guide Installation and Configuration 25 ...

Page 27: ...ad the tray into the bay a Insert the tray into the bay b Attach the screws 6 Attach the case cover a Place the cover on the NAS b Attach the screws TS hx77XU RP User Guide Installation and Configuration 26 ...

Page 28: ...al channel mode Ensure that each memory channel uses identical modules See table below for details Channel name Slot numbering Channel A Slots 1 2 Channel B Slots 3 4 Install the pairs in sequence and follow the assigned slots for each pair When installing one module use the slot furthest from the CPU slot 4 Install memory modules in groups of two or four When installing two memory modules install...

Page 29: ...ectrical outlet 3 Disconnect all cables and external attachments 4 Remove the front cover a Remove the screws b Lift the cover off the device 5 Remove an existing module a Push the retention clips outward simultaneously to release the module Warning Attempting to remove a module that is not completely released may damage the module and the motherboard b Hold the module by the edges TS hx77XU RP Us...

Page 30: ...lot c Verify that the metal connectors are completely inserted into the slot d Carefully press down on the module until the retention clips lock the module into place 7 Attach the case cover a Place the cover on the device b Attach the screws TS hx77XU RP User Guide Installation and Configuration 29 ...

Page 31: ... Ensure that each memory channel uses identical modules See table below for details Channel name Slot numbering Channel A Slots 1 2 Channel B Slots 3 4 When installing one module use the slot furthest from the CPU slot 4 Install the pairs in sequence and follow the assigned slots for each pair Install memory modules in groups of two or four When installing two memory modules install the memory in ...

Page 32: ...her body parts away from other moving components 1 Power off the device 2 Disconnect the power cord from the electrical outlet 3 Disconnect all cables and external attachments 4 Remove the case cover a Loosen the screws b Slide the cover back c Lift the cover off the device TS hx77XU RP User Guide Installation and Configuration 31 ...

Page 33: ...Warning Attempting to remove a module that is not completely released may damage the module and the motherboard b Hold the module by the edges 6 Install a new module a Align the notch with the ridge in the slot b Insert the module into the slot TS hx77XU RP User Guide Installation and Configuration 32 ...

Page 34: ...to the slot d Carefully press down on the module until the retention clips lock the module into place 7 Attach the case cover a Place the cover on the device b Slide the cover forward c Tighten the screws TS hx77XU RP User Guide Installation and Configuration 33 ...

Page 35: ...XU RP supports selected expansion cards some of which require QNAP PCIe brackets QNAP branded expansion cards purchased from the company website are shipped with the brackets necessary to fit all QNAP NAS models Replacing Expansion Cards on the TS h977XU RP Note A dual port 10GBase T network expansion card is pre installed on the PCIe 3 0 x16 slot Warning Moving fan blades Keep your hands and othe...

Page 36: ...external attachments 4 Remove the case cover a Remove the screws b Lift the cover off the device Warning To avoid potential injury or damage to components ensure that the drives and other internal system components have cooled before touching them 5 Remove the PCIe module a Remove the screws from the module b Remove the module from the chassis TS hx77XU RP User Guide Installation and Configuration...

Page 37: ...res the cover to the chassis b Hold the card by the edges c Carefully pull the card out of the slot 7 Install the expansion card a Hold the card by the edges b Insert the card into the slot c Attach the screw TS hx77XU RP User Guide Installation and Configuration 36 ...

Page 38: ...module with the system board b Insert the PCIe module connector into the system board slot c Attach the screws 9 Attach the case cover a Place the cover on the device b Attach the screws TS hx77XU RP User Guide Installation and Configuration 37 ...

Page 39: ... x8 to x4 if an expansion card is installed in slot 1 Slot 4 will reduce its speed from x8 to x4 if an expansion card is installed in slot 3 Note The following note is applicable to TS h2477XU RP A dual port 10GbE SFP network expansion card is pre installed on PCIe 3 0 x8 slot 4 Slot 2 will reduce its speed from x8 to x4 if an expansion card is installed in slot 1 Slot 3 will reduce its speed from...

Page 40: ...onents 1 Power off the device 2 Disconnect the power cord from the electrical outlet 3 Disconnect all cables and external attachments 4 Remove the case cover a Loosen the screws b Slide the cover back c Lift the cover off the device TS hx77XU RP User Guide Installation and Configuration 39 ...

Page 41: ...res the cover to the chassis b Hold the card by the edges c Carefully pull the card out of the slot 6 Install the expansion card a Hold the card by the edges b Insert the card into the slot c Attach the screw TS hx77XU RP User Guide Installation and Configuration 40 ...

Page 42: ...7 Attach the case cover a Place the cover on the device b Slide the cover forward c Tighten the screws TS hx77XU RP User Guide Installation and Configuration 41 ...

Page 43: ...re power supply unit PSU cords To avoid serious injuries a trained service technician must disconnect all PSU cords before installing or replacing system components 1 Power off the NAS 2 Disconnect the power cord from the electrical outlet and the power supply unit PSU that you are replacing 3 Firmly press the latch toward the handle and then pull the PSU out TS hx77XU RP User Guide Installation a...

Page 44: ...rical outlet 6 Power on the device 7 Enable alerts for PSU failures a Log on to QuTS hero as administrator b Go to Control Panel System Hardware General c Select Enable Redundant Power Supply Mode d Click Apply All TS hx77XU RP User Guide Installation and Configuration 43 ...

Page 45: ...n angle bracket a Align the openings on the handle with the two round screw holes on the angle bracket b Attach the screws to lock the handle to the angle bracket 3 Install the angle bracket on the device a Align the holes on the angle bracket with the holes on the chassis Note Ensure that the handle faces the same direction as the front panel b Attach the screws TS hx77XU RP User Guide Installati...

Page 46: ...A03 57 TS h2477XU RP RAIL A02 90 You can find installation information in the rail kit package Expansion Unit Installation The TS hx77XU RP supports SAS expansion units USB expansion units and SATA JBOD expansion units For details please see table below You can purchase storage expansion accessories from QNAP or an authorized reseller For details go to https shop qnap com For the list of compatibl...

Page 47: ...ce Supports SAS SATA HDD SSD One of the following storage expansion cards SAS 12G2E QXP 820S B3408 QXP 1620S B3616W mini SAS SFF 8644 cable RAIL B02 TL R1220Sep RP TL D400S Uses a SATA 6 Gbps SFF 8088 interface Supports SATA HDD SSD 1 x SFF 8088 connector cable QXP 400eS A1164 host bus adapter TL D800S 2 x SFF 8088 connector cables QXP 800eS A1164 host bus adapter TL D1600S 4 x SFF 8088 to SFF 864...

Page 48: ...SB 3 2 Gen 2 Type C interface Supports SATA drives USB 3 2 Gen 2 Type A to Type C cable USB 3 2 Gen 2 Type C to Type C cable TL R1200C RP USB 3 2 Gen 2 Type A to Type C cable USB 3 2 Gen 2 Type C to Type C cable RAIL B02 Connecting SAS Expansion Units To connect the device to SAS expansion units a storage expansion card must be installed in the device For required accessories details see Expansion...

Page 49: ...TS h977XU RP TS hx77XU RP User Guide Installation and Configuration 48 ...

Page 50: ...ministrator b Go to Main Menu Storage Snapshots Overview System c Verify that the expansion units are listed Connecting SATA JBOD Expansion Units To connect the device to SATA JBOD expansion units a host bus adapter must be installed on the NAS For required accesssories details see Expansion Unit Installation TS hx77XU RP User Guide Installation and Configuration 49 ...

Page 51: ...pansion units TL R400S and TL R1200S RP 4 Power on the SATA JBOD expansion units 5 Power on the NAS 6 Verify that the expansion units are recognized by the NAS a Log on to QuTS hero as administrator b Go to Main Menu Storage Snapshots Overview System c Verify that the expansion units are listed Connecting USB Expansion Units To connect the device to USB expansion units USB Type A to USB Type C cab...

Page 52: ...erify that the expansion units are listed QuTS hero Installation The TS hx77XU RP uses the QNAP QuTS hero operating system You can install QuTS hero using any of the following methods Method Description Requirements Qfinder Pro installation Recommended If the NAS is connected to your local area network you can do the following Locate the NAS using Qfinder Pro Complete the steps in the Smart Instal...

Page 53: ...nt file systems Switching operating systems will reset the NAS and delete all data Installing QuTS hero Using Qfinder Pro Warning Installing QuTS hero deletes all data on the drives Back up your data before proceeding 1 Power on the device 2 Connect the device to your local area network 3 Run Qfinder Pro on a computer that is connected to the same local area network Note To download Qfinder Pro go...

Page 54: ...ne date and time Tip QNAP recommends connecting to an NTP server to ensure that the NAS follows the Coordinated Universal Time UTC standard 10 Click Next The Configure the network settings screen appears 11 Select Obtain an IP address automatically DHCP 12 Click Next The Cross platform file transfer service screen appears 13 Select the types of devices that you will use to access shared folders on...

Page 55: ... wizard opens in the default web browser 5 Create an account or sign in to myQNAPcloud Note You must return to this page to complete the installation after creating an account 6 Specify the myQNAPcloud device name for the NAS Note The myQNAPcloud device name is used when remotely accessing the NAS For security purposes the myQNAPCloud Link remote connection service will be disabled on your NAS aft...

Page 56: ...yphens but cannot end with a hyphen Password Specify an administrator password with 1 to 64 characters The password supports all ASCII characters 12 Click Next 13 Specify the time zone date and time Tip QNAP recommends connecting to an NTP server to ensure that the NAS follows the Coordinated Universal Time UTC standard 14 Click Next The Configure the network settings screen appears 15 Select Obta...

Page 57: ... 22 Optional Click Go to NAS Management Tip Click Go to NAS Management to set more advanced QuTS hero configurations and settings For details see QuTS hero User Guide TS hx77XU RP User Guide Installation and Configuration 56 ...

Page 58: ...without special characters For example if the first MAC address is 00 08 9B F6 15 75 then the admin password will be 00089BF61575 Tip You can find the first MAC address using Qfinder Pro A label attached to the device also lists the address as MAC1 TCP IP configuration Obtain IP address settings automatically via DHCP Disable jumbo frames If port trunking is enabled multi LAN models only the port ...

Page 59: ...he firmware do not remove the power cord or USB cable and do not force exit the application Red The drive is invalid The shared folder has reached its full capacity The shared folder is about to reach its full capacity The system fan is not functioning An error occurred when accessing read write the data A bad sector is detected on the hard drive The device is in degraded read only mode two member...

Page 60: ...pansion unit is connected Off No expansion unit has been detected Audio Alert Duration Frequency Description Short beep 0 5 seconds 1 The NAS is starting up When the reset button is pressed for 3 seconds the NAS resets configurations When the reset button is pressed for 10 seconds the NAS resets configurations and reboots The operating system was updated The device is starting USB One Touch Copy 2...

Page 61: ... occurred The shared folder is about to reach its full capacity The shared folder has reached its full capacity The drives are in degraded mode The drive is rebuilding The USB device is being removed USB one touch copy button A shared folder status error occurred A drive is plugged in or out The iSCSI is about to reach full capacity 1 The NAS was powered off by force shutdown hardware shutdown The...

Page 62: ...mber drive fails RAID 6 4 One or two member drives fail RAID 10 6 One disk per subgroup fails RAID 60 8 Two disks per subgroup fail Triple Mirror Multiple of 3 For example 3 6 9 12 disks and so forth One or two member drives fail RAID TP 5 One two or three member drives fail 1 Log on to QuTS hero 2 Go to Main Menu Storage Snapshots Storage Disks VJBOD 3 Locate the failed drive 4 Prepare a new hard...

Page 63: ...y List https www qnap com compatibility NAS Migration Compatibility https www qnap com en nas migration Expansion Unit Compatibility http www qnap com go compatibility expansion Service Portal https service qnap com Product Support Status https www qnap com en product eol php Downloads https download qnap com Community Forum https forum qnap com QNAP Accessories Store https shop qnap com TS hx77XU...

Page 64: ...o access QNAP devices over the internet without configuring complex port forwarding settings QNAP ID User account that enables you to use myQNAPcloud remote access and other QNAP services Qfinder Pro QNAP utility that lets you locate and access QNAP NAS devices in your local area network QuTS hero QNAP NAS operating system featuring ZFS file system TS hx77XU RP User Guide Glossary 63 ...

Page 65: ...QNAP makes no warranty or representation expressed implied or statutory with respect to its products or the contents or use of this documentation and all accompanying software and specifically disclaims its quality performance merchantability or fitness for any particular purpose QNAP reserves the right to revise or update its products software or documentation without obligation to notify any ind...

Page 66: ...his version of the GPL to prohibit the practice for those products If such problems arise substantially in other domains we stand ready to extend this provision to those domains in future versions of the GPL as needed to protect the freedom of users Finally every program is threatened constantly by software patents States should not allow patents to restrict development and use of software on gene...

Page 67: ...e work The Corresponding Source need not include anything that users can regenerate automatically from other parts of the Corresponding Source The Corresponding Source for a work in source code form is that same work 3 Basic Permissions All rights granted under this License are granted for the term of copyright on the Program and are irrevocable provided the stated conditions are met This License ...

Page 68: ...not combined with it such as to form a larger program in or on a volume of a storage or distribution medium is called an aggregate if the compilation and its resulting copyright are not used to limit the access or legal rights of the compilation s users beyond what the individual works permit Inclusion of a covered work in an aggregate does not cause this License to apply to the other parts of the...

Page 69: ...urs as part of a transaction in which the right of possession and use of the User Product is transferred to the recipient in perpetuity or for a fixed term regardless of how the transaction is characterized the Corresponding Source conveyed under this section must be accompanied by the Installation Information But this requirement does not apply if neither you nor any third party retains the abili...

Page 70: ...vered work except as expressly provided under this License Any attempt otherwise to propagate or modify it is void and will automatically terminate your rights under this License including any patent licenses granted under the third paragraph of section 11 However if you cease all violation of this License then your license from a particular copyright holder is reinstated a provisionally unless an...

Page 71: ...uch an agreement or commitment not to enforce a patent against the party If you convey a covered work knowingly relying on a patent license and the Corresponding Source of the work is not available for anyone to copy free of charge and under the terms of this License through a publicly available network server or other readily accessible means then you must either 1 cause the Corresponding Source ...

Page 72: ...ublished by the Free Software Foundation If the Program specifies that a proxy can decide which future versions of the GNU General Public License can be used that proxy s public statement of acceptance of a version permanently authorizes you to choose that version for the Program Later license versions may give you additional or different permissions However no additional obligations are imposed o...

Page 73: ... device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of...

Page 74: ...當的對策 SJ T 11364 2006 本产品符合中国 RoHS 标准 以下表格标示此产品中某有毒物质的含量符合中国 RoHS 标准规定的限量要求 本产品上会附有 环境友好使用期限 的标签 此期限是估算这些物质 不会有泄漏或突变 的年限 本产品 可能包含有较短的环境友好使用期限的可替换元件 像是电池或灯管 这些元件将会单独标示出来 部件名称 有毒有害物质或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 CR VI 多溴联苯 PBB 多溴二苯醚 PBDE 壳体 0 0 0 0 0 0 显示 0 0 0 0 0 0 印刷电路板 0 0 0 0 0 0 金属螺帽 0 0 0 0 0 0 电缆组装 0 0 0 0 0 0 风扇组装 0 0 0 0 0 0 电力供应组装 0 0 0 0 0 0 TS hx77XU RP User Guide Notices 73 ...

Page 75: ...物质或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 CR VI 多溴联苯 PBB 多溴二苯醚 PBDE 电池 0 0 0 0 0 0 O 表示该有毒有害物质在该部件所有物质材料中的含量均在 SJ T11363 2006 标准规定的限量要求以下 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T11363 2006 标准规定的限量要求 TS hx77XU RP User Guide Notices 74 ...