background image

LED indication and configuration

Table 2: Device configuration state

#

Configuration

Definition

1

Activation LED enabled

Green LED appears when the load is on. Green LED

does not appear when the load is off.

2

Activation LED disabled

LED is always off.

Note: 

The PowerG signal strength test blinking

overrides the Activation LED disabled mode.

Note: 

 If the connection fails and the LED indicator turns off, reset the device to factory

default. For more information see, 

Resetting the device

.

Additional behavior of the device

Behavior

Corresponding behavior

Turn the socket on or off using the built-in

button

The IQ Panel updates the status within 10

seconds.

When enrolled

The IQ Panel registers the device as a PowerG

device.

When power is removed from the device

The IQ panel updates the device status to

unreachable within 14 minutes.

When power is restored to the device

The IQ panel automatically updates the device

status to normal within 5 minutes.

When communication is lost and then restored The IQ panel automatically updates the device

status to normal within 5 minutes.

Resetting the device

1. Press and hold both buttons for 2 seconds. The LED turns orange to indicate a long press.

2. Release briefly, then press and hold the button again for 5 seconds until the LED turns red

and flashes 3 times to indicate a reset to factory default.

Note:

- After the reset, the device does not start enrollment automatically. For more

information on device enrollment, see 

Resetting the device

.

- After a device is reset back to factory default, you must delete it from the panel and

re-enroll the device.

Troubleshooting

WARNING: 

The wiring should only be changed in accordance with applicable electrical codes

and regulations in your region.

WARNING: 

Only a qualified professional should attempt to change electrical wiring.

5

IQ Smart Socket-PG Installation Guide

D-308964 IQ Smart Socket-PG Install Guide

Summary of Contents for IQ Smart Socket-PG

Page 1: ...hat the combined current of all connected devices does not exceed 15 Amps Keep this manual as it contains important technical data testing and troubleshooting information which may be useful after ins...

Page 2: ...re that the electricity supply to the area is turned off Failure to do so may result in electric shock or serious injury 1 Turn the power off at the circuit breaker 2 Remove the existing socket and co...

Page 3: ...ce until the LED turns orange for 2 seconds 3 Release both buttons and the LED turns off The device enters enrollment mode and the panel is notified of the device initiating enrollment 4 When the devi...

Page 4: ...s successfully Considerations when you enroll a device The following considerations apply when you enroll a device with PowerG or when you enroll a device with Auto Learn enroll If the buttons remain...

Page 5: ...restored to the device The IQ panel automatically updates the device status to normal within 5 minutes When communication is lost and then restored The IQ panel automatically updates the device statu...

Page 6: ...rature 0 C to 40 C or 32 F to 104 F Storage temperature 20 C to 55 C or 4 F to 131 F Operating humidity 0 to 90 RH Non condensing Color White Dimensions 115 6 mm x 70 6 mm x 46 6 mm or 4 55 in x 2 78...

Page 7: ...on between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician...

Page 8: ...eryday waste Directive 2012 19 EU Waste Electrical and Electronic Equipment Warranty and EULA To access Warranty and EULA information access the following link https bit ly 3NuoY8o or scan the followi...

Reviews: