PROGRAMMING
INSTALLER/DEALER SETTINGS
Setting
Default
Description
EN Grade 2
Disabled
This setting is required for EN Grade 2 compliance on the Panel and must be Enabled for
EN Grade 2 installations. When Enabled, the following behaviors and/or settings are
changed automatically:
- Entry Procedure (EU) - follows entry procedures and alarm transmission delays
specified by EN 50131
- Disables the “Auto Bypass” setting so that the Panel will protest arming when sensor
and panel trouble conditions are present (i.e. Open, Tamper, Low Battery, etc)
- Trouble condition alerts can not be acknowledged until the condition is resolved
- Trouble beeps are expanded to include fault indications required by EN 50131
- “Screen Lock” setting is enabled automatically. Screen will lock 30 seconds after
Disarming
- A new icon called “EU Events” is added to the “Settings" page which records mandatory
history events specified by EN 50131.
- “Loss of Supervisory Signals for PowerG Non-Emergency Sensors” is set to 2 hours by
default.
- “LED Indicator” setting is Disabled automatically.
- “Partitions” setting is not available.
- “Dealer or Installer Access Requires User Permission” setting is Enabled automatically.
EU Event Swinger Shutdown Count
3
Determines the number of times a particular event will record to “EU Events” log before
shutdown. The count (3-10) will reset after and arm or disarm event.
NOTE:
This setting is
greyed out and not selectable unless EN Grade 2 is Enabled.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF
30
173
Summary of Contents for Panel 2+
Page 8: ...INSTALLING THE PANEL...
Page 13: ...USER INTERFACE...
Page 17: ...PROGRAMMING...
Page 52: ...SECURITY SENSORS...
Page 84: ...WI FI DEVICES...
Page 91: ...Z WAVE DEVICES...
Page 102: ...BLUETOOTH DEVICES...
Page 110: ...SYSTEM TESTS...
Page 134: ...CUSTOMIZATION...
Page 147: ...MAINTENANCE...
Page 153: ...TROUBLESHOOTING...
Page 163: ...LEGAL...
Page 169: ...SPECIFICATIONS...