PROGRAMMING
SIREN AND ALARMS
Setting
Default
Description
Dialer Delay
:30
Amount of time (in seconds) before panel will attempt call to central station after an alarm
event is triggered
When SIA Limits enabled: :15 to :45 seconds
When SIA Limits disabled: :0 to :254 seconds
Siren Timeout
4 min
Determine how long before siren stops sounding during an alarm event (4 minutes to 15
minutes).
NOTE
: For EN Grade 2 the minimum bell time out shall be 90s & maximum bell time out shall not exceed
local regulations.
Water/Freeze Siren
Disabled
When enabled, siren will sound when a water or freeze detector is triggered. When
disabled, the panel emits a “water” tone
PowerG Smoke Detector Siren
Fire Alarms Only
When set to “Fire Alarms Only”, PowerG Smoke Detectors that are learned into the
system will only sound during fire alarm events. When set to “All Alarms”, PowerG Smoke
Detectors will act as additional wireless sirens and will sound during all alarm events.
Police Panic
Enabled
Allows Police Panic to be enabled or disabled
Fire Panic
Enabled
Allows Fire Panic to be enabled or disabled
Auxiliary Panic
Enabled
Allows Auxiliary Panic to be enabled or disabled
Allow Master Code To Access Siren
and Alarms
Disabled
Allow the master code to access these features and settings.
NOTE
: Shall not be used for EN Grade 2
Summary of Contents for Panel 2+
Page 8: ...INSTALLING THE PANEL...
Page 13: ...USER INTERFACE...
Page 17: ...PROGRAMMING...
Page 52: ...SECURITY SENSORS...
Page 84: ...WI FI DEVICES...
Page 91: ...Z WAVE DEVICES...
Page 102: ...BLUETOOTH DEVICES...
Page 110: ...SYSTEM TESTS...
Page 134: ...CUSTOMIZATION...
Page 147: ...MAINTENANCE...
Page 153: ...TROUBLESHOOTING...
Page 163: ...LEGAL...
Page 169: ...SPECIFICATIONS...