SENSOR GROUPS
FREEZE
GROUP
NAME
SUPERVISED
SCENARIO
52
Freeze
Y
Triggers an alarm when sensor detects low temperatures.
NOTE:
Temperature sensor functionality has not been evaluated by CE/EN Grade 2.
25
Freeze Non-Reporting
Y
Used for local alerts. Will not report an alarm to the Central Station
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF
69
173
Please note:
When using the PG8905 with Group 52, Freeze, the Low threshold setting is set to 4°C by default. The
Low threshold can be customized between -40°C and 85°C.
HIGH TEMPERATURE
GROUP
NAME
SUPERVISED
SCENARIO
53
Temp Reporting
Y
Triggers an alarm when sensor detects high temperatures.
NOTE:
Temperature sensor functionality has not been evaluated by CE/EN Grade 2.
25
Temp Non-Reporting
Y
Used for local alerts. Will not report an alarm to the Central Station
Please note:
When using the PG8905 with Group 53, the High threshold setting is set to 38°C by default. The High
threshold can be customized between -40°C and 85°C.