- 17 -
Press
to show D-1, D-2, D-3, D-4 in order. Press up and down button to regulate the value
of specification, If the buttons are not pressed in 1 minute, the specification setting state will
be automatically ended.
Mode
Description
Range
Default
D-1
Temp Unit
0-°C, 1-°F
0-°C
D-2
Temp Adjustment
-100---100°C (-148°F --- 212°F)
0
D-3
Temp Alarm
10-170°C (50°F - 338°F)
150°C (302°F)
D-4
Temp max
10-150°C (50°F - 302°F)
120°C (248°F)
Set End Exit
Notes:
The specificat ions are set when shipped from the factory. Do not change the
specifications at random.
It normally takes 20 minutes for the top roller to reach the temperature of 50
℃
(122
℉
).
It is normal that the temperature display differs the room temperature when start heating.
V. USAGE OF MACHINE
Power Connection
Power cable:
It was installed the standard power supply plug, before plug in, please
check your power supply voltage is same as the machine's rated operating voltage, also
should verify the access to the socket is in requirements, and have a good grounding,
and the capacity is large enough.
Main switch:
It is installed in the rear of machine (Cold series is the rocker switch, and
Warm series is the air brake switch), the switch has two positions, up to open, down to
close.
Foot pedal
Foot pedal is another way to control the start and stop roller rotating. Step on the foot pedal,
press the direction button to adjust the speed, then the roller runs, roller stops when loose.
Plug in and lock the screw before using
Note: The protect sensor can’t be used with foot pedal together.