background image

User Guide 

QRS Music Technologies, Inc. 

Item # 79317 

Manual # OM79217 

Manual Rev. 20170301 

PNOscan

PNOscan

PNOscan

 

 

 

III

III

III

 

 

 

If the PNOscan system is part of a PNO

3

 playback system you don’t need the box shown above.  

Summary of Contents for PNOscan III

Page 1: ... Guide QRS Music Technologies Inc Item 79317 Manual OM79217 Manual Rev 20170301 PNOscan PNOscan PNOscan III III III If the PNOscan system is part of a PNO3 playback system you don t need the box shown above ...

Page 2: ...esigns Benefits such as absolute high resolution key sampling with no mechanical contact with keys or action highly accurate DSP algorithms for outstanding performance After the initial installation the PNOscan III system was electronically setup to the piano action As your piano action wears it may be necessary to repeat this setup procedure periodically If the piano action is regulated or repair...

Page 3: ...le plug into your computer s USB socket and the 5 Pin MINI B Male plug into the connector that is attached to the piano See page 4 for this cable location Your computer will supply power to PNOscan III and should recognize PNOscan III as a USB device The PWR button will illuminate to indicate that the system is ON The Function button will blink when a key is pressed The PNOscan III is a MIDI Outpu...

Page 4: ...dj button to select one of the following Patch Changes The voices below are not internal to the PNOscan III PNOscan III is sending patch change messages to the device connected to the MIDI OUT port of the TUSB 1 Preset 1 Patch Change 1 Grand Piano Light blinks once then a pause 2 Preset 2 Patch Change 5 Electric Piano Light blinks twice then a pause 3 Preset 3 Patch Change 20 Church Organ Light bl...

Page 5: ...ibbon cable is disconnected or plugged in upside down at either the TUSB interface or the cable coupler At the TUSB the silver contact side is toward the bottom of the TUSB box At the cable coupler the silver contact side of the cables should face the circuit board B D Alternately Flashing Press and hold for about 2 5 seconds to power the system off Pressing when the system is off powers the syste...

Page 6: ...Pianomation or other MIDI device MIDI OUT H Standard MIDI input connection Normally not connected Used in more complex setups when communication to QRS diagnostic programs are needed MIDI IN I Connect a host computer to this port for convenient use of the PNOscan III system and computer software USB 2 0 compliant An extension cable 7921754 is provided and may already be connected to this port On a...

Page 7: ...l Setup Use the following sequence to setup the pedals The standard configuration includes a soft shift pedal and a sustain pedal The Sostenuto sensor is optional If used this pedal adjusts in the same way as the soft shift The pedal press sequence is Sustain Sostenuto and then Soft Shift 1 While holding the Pedal Adj button press and hold the Function button Hold both buttons until the Pedal Adj ...

Page 8: ...tend from the treble end of the keyboard TUSB 79210 Soft Pedal Circuit Board 79209 Sustain Pedal Circuit Board 79208 Key Scan Assembly Flex Cable Coupler 79206 12 6 pin 7921704 12 6 pin 7921704 20 6 pin 7921718 38 10 pin 7921706 Connection Diagram Upright Piano 20 6 pin 7921718 12 6 pin 7921704 38 10 pin 7921706 60 6 pin 790185 Optional AC Power Adapter 7921701 Not required when TUSB is connected ...

Page 9: ...nal Piano Software Go to http www epiano com qrs index php Troubleshooting No MIDI Output from TUSB Interface The Function and Key Adj lights are alternately flashing Alternately flashing Function and Key Adj lights indicate that a ribbon cable is disconnected or plugged in upside down at either the TUSB interface or the cable coupler At the TUSB the silver contact side is toward the bottom of the...

Page 10: ... are found to be defective in material or workmanship and the original purchaser provides Purchase Documents to QRS then QRS or its authorized dealer will provide replacement parts without charge We may at our discretion provide reconditioned parts or assemblies as warranty replacements You as the original purchaser will be responsible to pay labor costs incurred in connection with any repair LIMI...

Page 11: ...ter discovery and provide a detailed explanation of the problem General If any provision herein shall be unlawful void or for any reason unenforceable then that provision shall be deemed severable from this warranty certificate and shall not affect the validity of and enforceability of the remaining provisions QRS reserves the right to make changes in design and or improvements to its products wit...

Page 12: ...hi 110 Bag pipe 15 Tubular Bells 47 Orchestral Harp 79 Whistle 111 Fiddle 16 Dulcimer 48 Timpani 80 Ocarina 112 Shanai 17 Draw bar Organ 49 String Ensemble 1 81 Lead 1 square 113 Tinkle Bell 18 Percussive Organ 50 String Ensemble 2 82 Lead 2 saw tooth 114 Agogo 19 Rock Organ 51 SynthStrings 1 83 Lead 3 calliope 115 Steel Drums 20 Church Organ 52 SynthStrings 2 84 Lead 4 chiff 116 Woodblock 21 Reed...