Individual Sound Volumes
Primary Index entered into CV 49
Sound
Default
0
Horn
11
8
Bell
13
10
Diesel Motor
7
13
Turbine Whoosh
12
15
Turbine Whine
8
16
Air Pump
10
19
Diesel Motor Cooling Fans and Vents
8
21
Long Air Let-off
11
22
Short Air Let-off
11
24
Squealing Brakes
11
28
Dynamic Brakes
10
34
Coupler Sounds
11
Standard Throttle Control (STC), Speed Control (SC) and Regulated Throttle Control (RTC) Options (CV 56.4)
Set CV 49 to 4.
Set CV 56 to: 0 for Standard Throttle Control, 1 for Speed Control and 2 for Regulated Throttle Control.
Note: CV 2, CV 5 and speed tables are available for Standard and Regulated Throttle Control
41
but inactive for Speed Control. See DCC
Quantum Reference Manual (Version 3).
Reset all
42
CV’s to Factory Default Values (CV 56.128.255)
Note:
This does not affect Analog settings, except for volumes.
Set CV 49 to 128.
Set CV 50 to 255.
Set CV 56 to 113
43
. In Ops mode, you will hear 3 hoots when reset is completed.
Special Procedure for Short or Extended Address Programming (CV 56.129)
If you cannot program your Short or Extended ID number in Service Mode and your DCC command station prevents you from setting either of
these addresses in Ops Mode (using CV 1, or CV 17 and CV 18) use the following alternative procedures to program your locomotive’s ID’s.
Alternate Procedure for Entering Short (Primary) Address in CV 56.129.1 in Ops Mode
Set CV 49 to 129.
Set CV 50 to 1.
Set CV 56 to your Short Address (1 or 2 digits). Hear the address spoken back.
If necessary, set CV 29, bit 5 to ‘0’ (or set CV 29 to 6 which is factory default) to enable your new Primary Address.
Procedure for Entering Long (Extended) Address in CV 56.129.17 in Ops Mode.
Determine the value of CV 17 and CV 18 for your Extended Address from the ID Table in your
Diesel Model Specification Sheet or
follow instructions in CV 17 and CV 18 in the
Quantum DCC Reference Manual (Version 3) to calculate a different ID number.
Set CV 49 to 129.
Set CV 50 to 17.
Set CV 56 to the value of CV 17 from the table. There will be no verbal response.
Set CV 50 to 18.
Set CV 56 to the value of CV 18 from the table. Hear the new full Extended Address spoken out.
41
Regardless of the value of CV 2, RTC has a minimum speed of 1 smph at speed step 1.
42
Consult the Quantum DCC Reference Manual (Version 3) to learn how to reset different groups of CV’s.
43
“113” is QSI’s Manufacturer’s ID Number assigned by the NMRA.
Gas Turbine Locomotive Q1R Operation Manual Version 3.0
21/26
14 March 2006