Set CV 29, bit 5 to ‘1’ (or set CV 29 to 38
44
)
to allow operation with your new Extended Address.
Loco Number
CV 17
(Dec)
CV 18
(Dec)
CV 17
(Hex)
CV 18
(Hex)
CV 17
(Binary)
CV 18
(Binary)
61
192
61
C0
3D
11000000
00111101
64
192
64
C0
40
11000000
01000000
66
192
66
C0
42
11000000
01000010
71
192
71
C0
47
11000000
01000111
73
192
73
C0
49
11000000
01001001
75
192
75
C0
4B
11000000
01001011
Disable/Enable Verbal Announcements (CV 62)
In Ops Mode, the Quantum System will automatically speak out the value of the CV that you enter.
To disable set CV 62 to 0
45
; to enable set CV 62 to 1
46
. Default is “Enabled”.
CV Inquiry with Verbal Feedback in Ops Mode (CV 64)
47
To inquire about the current value of any CV through Verbal Feedback in Ops Mode:
Set CV 64 to the CV you wish to query. Hear the verbal message “CV ‘X’ equals ‘Y’”, where ‘X’ is the CV number and ‘Y’ is the value.
Note:
If the CV has a Primary Index such as QSI CV nn.pp (where nn is the CV number and pp is the Primary Index), set CV 49 to pp before you set CV
64 to nn. For example, if you want to inquire about the Diesel Motor Volume, which is CV 52.10, set CV 49 to 10 and set CV 64 to 52. You will hear, “CV
five two point one zero equals ‘Y’ (where ‘Y’ is the current volume setting). If the CV has both a Primary and Secondary Index, such as CV nn.pp.ss where
ss is the Secondary Index, set CV 50 to ss in addition to setting CV 49 to pp before you set CV 64 to nn. .
Note:
If you enter either ‘17’ or ‘18’ in CV 64, you will hear the full one to four digit Extended Address ID number spoken out.
Common NMRA Configuration Values (CV 29)
Each bit in CV 29 controls some basic operational setting for DCC decoders, including Extended Addressing, Speed Table Enable, Power
Source Conversion, Lighting Operation, Locomotive Direction, and others. Quantum default for CV 29 is 6.
The following table provides some of the more common values for CV 29 for the features indicated.
Extended
Addressing
Speed
Tables
Power
Conversion
28/128
Speed Steps
Reversed
Direction
Decimal
Value
Binary
Value
Hex Value
X
2
00000010
2
X
X
6
00000110
6
X
X
18
00010010
12
X
X
X
22
00010110
16
X
X
34
00100010
22
X
X
X
38
00100110
26
X
X
X
50
00110010
32
X
X
X
X
54
00110110
36
X
X
3
00000011
3
X
X
X
7
00000111
7
X
X
X
19
00010011
13
X
X
X
X
23
00010111
17
X
X
X
35
00100011
23
X
X
X
X
39
00100111
27
X
X
X
X
51
00110011
33
X
X
X
X
X
55
00110111
37
For more information, download the
Quantum DCC Reference Manual (Version 3) from http://www.qsindustries.com.
44
Entering “38” leaves the other configuration settings in CV 29 at factory default, but changes the ID to Extended Address type.
45
You will not hear “CV 62 equals 0”.
46
You will hear “CV 62 equals 1”.
47
This option is not affected by CV 62 (Disable/Enable Verbal Announcements).
Gas Turbine Locomotive Q1R Operation Manual Version 3.0
22/26
14 March 2006