The ECS scale 

does not 

need to be calibrated for normal use. Calibration is required 

only for ISO certification.  
  

Procedure: 

 
Turn the scale on. Press the UNITS key repeatedly until scale displays, “lbs.” 
 
Turn the scale off and turn it upside down. You will see a small black switch in a hole on the 
underside of the scale. Move the switch to the left from “LOCK” to “ADJ”. Turn the scale right 
side up. 
 
Press and hold down the TARE key. While continuing to hold the TARE key down, use another 
finger to press and hold down ON/ZERO key. Both keys should now be held down. In exact 
sequence, first release the ON/ZERO key, and then the TARE key. The scale will display 
“01C5P” (the top stroke of the “5” will be missing). If it does not display exactly, repeat this 
process. 
 
Next, select from the following instructions based on the capacity of your scale: 

CALIBRATION:  

 Calibration Instructions 

Procedure for the ECS 5 (5 lb. Capacity): 

 
Press the ON/ZERO key once. The scale will read “02CAL”. 
 
Press the TARE key once. The scale will display “2500” (with last “0” blinking). 
 
Press the ON/ZERO key once. 
  
Press the TARE key. The scale will first display “CEntr”, and then, “2500”. 
 
Place 2500 grams on the scale in the form of a certified test weight, allow the display to 
stabilize, and then  press the TARE key once - the scale will beep three times. 
 
Turn the scale off and turn over. Move black switch right from “ADJ” to “LOCK”. 
 
Turn scale back on. The scale is now calibrated and ready for use. 

 

Procedure for the ECS 10 (10 lb. Capacity): 

 
The method is identical to the 5 lb. model above except that a value of ‘5000’ will be displayed 
instead of ‘2500’, and you should use a 5000 gram test weight for calibration. 

 

Procedure for the ECS 20 (20 lb. Capacity): 

 
The method is identical to the 5 lb. model above except that a value of ‘10000’ will be 
displayed instead of ‘2500’, and you should use a 10,000 gram test weight for calibration. 

Summary of Contents for ECS Series

Page 1: ...Email info QTechScales com Web Site www QTechScales com Installation and Operating Instructions The Perfect Counting Scale for Any Application Copies of this manual are available in Adobe Acrobat PDF format on our website Counting Weighing Shipping Inventory Control Batching 5 10 or 20 lb Capacity ...

Page 2: ...ndicator arrow will appear above the oz symbol on the display Locate your scale on a solid level work surface free from air drafts and vibrations While precise leveling of the scale is not required you may get inaccurate results if all four adjustable feet are not in contact with the work surface For Consistent and Accurate Results Avoid scale placement near windows fans and air conditioning or he...

Page 3: ... pieces and place that exact amount of items on the scale Next press the UNITS key CAL will appear and then the scale will display the selected sample size in the window Select from the following sampling procedures depending on the item you wish to count FUNCTION How to Sample 2 Sheet Size Sampling Procedure 8 1 2 x 11 Press the NET GROSS key to cycle through the available samples sizes and selec...

Page 4: ...rst and then tare out a weight or you can tare out a weight and then sample with the container on the scale Remember that the weight should always be 0 before sampling Function Procedure To Eliminate the Weight of a Box or Expansion Platter Place the container or expansion platter on the scale and press the TARE key NOTE The scale must be in the grams lbs or oz mode for the Tare function to work P...

Page 5: ...ng is uniform in weight the scale will always display the correct count plus or minus one or two pieces per thousand Incorrect counts are most often the result of one or more of the following factors A Miscount During Sampling The scale is dependent on the operator for the accuracy of the sampling count If you set the scale for a 50 piece sampling but there are actually only 49 pieces you will get...

Page 6: ...e CALIBRATION Calibration Instructions Procedure for the ECS 5 5 lb Capacity Press the ON ZERO key once The scale will read 02CAL Press the TARE key once The scale will display 2500 with last 0 blinking Press the ON ZERO key once Press the TARE key The scale will first display CEntr and then 2500 Place 2500 grams on the scale in the form of a certified test weight allow the display to stabilize an...

Page 7: ...Resolution 1 Part in 300 000 Capacities 3 lbs QCS 3 6 lbs QCS 6 15 lbs QCS 15 30 lbs QCS 30 65 lbs QCS 65 Resolution 1 Part in 600 000 QCS 3 1 part in 2 000 000 QCS Series For Fast One Button Counting of Pennies Nickels Dimes Quarters Fifty cent pieces and Dollar Coins Capacity 60 lbs EZ 60 Resolution 1 Part in 600 000 EZ 60 High Capacity Heavy Duty Counting Scale with Detachable Console Capacity ...

Page 8: ...ech you can always expect 90 DAY money back guarantee A Full 3 YEAR Product Warranty TOLL FREE phone technical support at no charge for as long as you own the scale PROFESSIONAL courteous and timely response to your inquiries questions or concerns Customer Satisfaction is the Driving Force at QTech 129 Cramer Road Jewett New York 12444 USA 800 831 4175 518 734 6514 Fax 518 734 6497 Email info QTec...

Reviews: