background image

Remove the contents from the carton which includes the scale, platter, and the AC adaptor.  
Install the  platter  by  inserting the  pins  on the  underside into  the  holes on  the  top  of  the  scale 
console. The sloped edge of the platter should face forward. If any of the pins are bent, contact 
QTech; inaccurate counts may result. 

 

The scale is battery powered with the AC adapter functioning as the charger. Since the battery 
ships with only a partial charge, allow the unit to charge for at least 10 minutes before initial use. 
(A full charge requires 8 to 12 hours.) When charging, first insert the plug into the jack on the left 
side of the unit and then plug the transformer into a standard 110/120 volt AC outlet. The  power 
indicator light on the scale will glow red when recharging. As the charge approaches completion 
the light will change to yellow and finally green, indicating a full charge. The scale power switch 
need not be in the “on” position during charging.  

 

A  full  battery  will  hold  a  charge  for  about  two  months  providing  approximately  200  hours  of 
continuous  use.  The  scale  will  require  recharging  when  the  battery  symbol 

appears in 

the  lower  right  corner  of  the  WEIGHT  window.  Since  the  battery  can  be  damaged  if  it  is 
discharged too much, the scale will automatically power off if the battery is not recharged within 
20 hours of the first appearance of the warning symbol. 

 

Locate your scale on a solid, level work surface free from air drafts and vibrations. Tighten the 
two black disks of the leveling feet together, and then hand tighten them as a unit into the base. 
If the  scale is  not  steady,  loosen  and extend only  one of the feet to eliminate any  imbalance.  
While  precise  leveling  of  the  scale  is  not  required,  you  may  get  inaccurate  results  if  all  four 
adjustable feet are not in contact with the work surface, or are extended too far. 

For Consistent and Accurate Results: 

 

 

Avoid placement near drafts, windows, fans, or air conditioning and heating vents. Do 
not leave anything on the scale platter when not in use.

 

 

Use a surge protector with the AC adaptor to minimize the effects of voltage spikes. 

 

 

Do not fill containers with coins or tokens while on the scale platter.

  

Always fill off the 

platter to avoid damage to the sensitive scale load cell.

 

 

To avoid electronic interference do not operate cell phones within 6 feet of the scale. 

Important: 

Save the shipping carton and all packing materials should it be necessary 

to return the unit to the factory for service.  

CAUTION: 

The AC adaptor supplied with the scale is a proprietary design. Should it 

ever fail, replace only with a QTech supplied adaptor. The use of any other brand may 
result in scale and/or battery damage as well as voiding your warranty.  

Summary of Contents for EZ-60

Page 1: ...A 800 831 4175 518 734 6514 Fax 518 734 6497 Email info QTechScales com Web Site www QTechScales com Copies of this manual are available in Adobe Acrobat PDF format on our website Retail Stores Laundr...

Page 2: ...automatically power off if the battery is not recharged within 20 hours of the first appearance of the warning symbol Locate your scale on a solid level work surface free from air drafts and vibratio...

Page 3: ...ly counted in a bucket or tray the first step is to cancel out or tare the weight of the container Place an empty container on the scale and press the T tare key the weight window will now display 0 R...

Page 4: ...ll display for about 3 seconds and then revert to the quantity on the scale at the present time Proceed in this fashion with each additional lot 3 Recall the Subtotal Although the subtotal quantity wi...

Page 5: ...individual token accurate to four decimal places As you key in the numbers they will appear in the DENOMINATION window from right to left A Gold token typically weighs 5 085 grams and a Silver 5 550...

Page 6: ...used the tare feature there will be a negative count weight stored in the scale s memory To delete the tare weight remove the container from the scale platter and press the Z Key Note that you can no...

Page 7: ...High Capacity Heavy Duty Counting Scale with Detachable Console Capacity 150 lbs QCS 150 QCS 150 15 lbs QCS 15 30 lbs QCS 30 65 lbs QCS 65 Our Most Popular and Versatile Model For Every Counting Appl...

Page 8: ...ounting ink mixing weighing and shipping scale needs Our goal is to provide quality products and exceptional service and support At QTech you can always expect 90 DAY money back guarantee A Full 3 YEA...

Reviews: