Configuration manual
8. System Alarm
88
www.qtech.ru
8
SYSTEM ALARM
8.1
Overview
With the system alarm function, if an exception occurs, the system sends an alarm prompt
message so that the user can pay attention to the exception of the device and take the
corresponding measures to ensure stable operation of the device. System alarms include
temperature alarms, power supply abnormality alarms, fan abnormality alarms, and system
shielding function. For the system temperature alarms, if the CPU or environment temperature
reaches the threshold, abnormal system alarm log information is generated. By default, the
CPU temperature alarm threshold is 85° and the environment temperature alarm threshold is
75°. Power supply and fan exceptions also generate abnormal system alarm log information.
8.2
System Alarm Function Configuration
Table 8-1 System alarm function list
Configuration Tasks
Configure system temperature
alarms.
Configure system temperature alarms.
Configure system power supply
alarms.
Configure system power supply alarms.
Configure system fan alarms.
Configure system fan alarms.
Configure
system
alarm
parameters.
Configure the type of system alarms to be
shielded.
8.2.1
Configure System Temperature Alarms
Configuration Condition
Before configuring system alarms, ensure that:
After the system is started and operates stably, all boards are loaded successfully.
After the system is started and operates stably, the power supply and fans operate
normally.
Configure System Temperature Alarms
In configuring system temperature alarms, you need to configure the temperature threshold
for CPU or environment alarms. If the CPU temperature or environment temperature reaches
the threshold, system alarm log information is generated. By default, the CPU temperature
alarm threshold is 95 the temperature alarm threshold of the air outlet is 80°, and the
temperature alarm threshold of the switching chip is 95°.
Table 8-2 Configuring system temperature alarms