160.473UK User Manual
Setting up
Make sure that none of the remote timer control buttons are pressed in at startup
Aim the outlet nozzle toward the area where the effect is required but away from contact with people.
Switch the mains power on (1)
Heat up time for fog effect is usually between 8-10 minutes.
During prolonged use, periodically check that the fluid level is not empty
Switch off when not in use. Unplug from mains if not in use for long periods
Warning: There will be hot surfaces on the housing even after the machine is switched off
Remote timer control
When the machine is ready to operate, the ready light (5) on the remote timer control will illuminate.
You may now press the Manual (3) button for fog on demand – releasing button stops the fog effect
When the ready indicator is off, the QTFX-2000 mkII needs time to re-heat and will not produce fog
For constant fog effect, use the latching Continuous (2) button and the Continuous LED (6) will light
The density of fog effect can be varied by adjusting the rotary Output control (7)
Pressing the Timer button (1) will activate the hands-free timer function and the timer LED (4) will light
The Interval control (8) adjusts the time between fog effect output in each timer cycle
The Duration control (9) adjusts the length of time that fog is produced in each timer cycle
Wireless remote control
Fog can also be controlled manually by the wireless remote control
The key fob remote is powered by a button cell, replace this with similar type if discharged
Extend the antenna on the key fob, slide down the front cover
Press one of the key fob buttons to produce fog
DMX operation
The QTFX-2000 mkII can be operated by a single channel of DMX512 control.
Set this address via the rear panel DIP switches as shown above
A value of 0 will give no fog output. A value between 1 and 255 will give full fog output.
When a DMX signal is detected, the DMX indicator (7) will flash when data is being received.
1.
Timer button (latching) - activates the timer control
2.
Continuous button (latching) – overrides timer control for constant fog
3 . Manual button (non-latching) – overrides timer control for fog on demand
4.
Timer indicator – illuminated when timer function is active
5.
Ready indicator – illuminated when heated up ready to produce fog
6.
Continuous indicator – illuminated when continuous function is active
7.
Output control – adjusts the amount and density of fog effect
8.
Interval control – adjusts the interval between fog output on timer control
9.
Duration control – adjusts the time length of fog output on timer control